Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleTeaching Case Study

Thyroid Scintigraphy and SPECT/CT in a Rare Case of Dual Ectopic Thyroid

Sanchay Jain, Suruchi Jain and Deepa Singh
Journal of Nuclear Medicine Technology December 2022, 50 (4) 375-376; DOI: https://doi.org/10.2967/jnmt.122.264508
Sanchay Jain
1Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Suruchi Jain
2Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Deepa Singh
3Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 50 no. 4 375-376
DOI 
https://doi.org/10.2967/jnmt.122.264508
PubMed 
36041877

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Received for publication June 10, 2022
  • Accepted for publication July 22, 2022
  • Published online December 7, 2022.

Article Versions

  • previous version (August 30, 2022 - 12:05).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2022 by the Society of Nuclear Medicine and Molecular Imaging.

Author Information

  1. Sanchay Jain1,
  2. Suruchi Jain2 and
  3. Deepa Singh3
  1. 1Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India;
  2. 2Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India; and
  3. 3Department of Nuclear Medicine, All India Institute of Medical Sciences, Bhopal, India
  1. For correspondence or reprints, contact Suruchi Jain (suruchi.nuclearmed{at}aiimsbhopal.edu.in).
View Full Text

Statistics from Altmetric.com

Cited By...

  • 2 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Advances in Radionuclide Imaging With SPECT/CT
    Daniel J Wale
    Seminars in Roentgenology 2025
  • Diagnóstico de glándula tiroidea ectópica por gammagrafía
    Mario Germán Montes-Osorio, Lilyana Carrizales-Medina, Miguel Ángel Vázquez-Monroy, Dora María Estrada-Durán
    Revista Mexicana de Pediatría 2023 90 2

Article usage

Article usage: August 2022 to April 2025

AbstractFullPdf
Aug 20225102
Sep 202219407
Oct 202210006
Nov 20229302
Dec 202222735
Jan 202325552
Feb 202320375
Mar 202310071
Apr 20236810
May 20235021
Jun 20233700
Jul 20234931
Aug 20234010
Sep 20232612
Oct 20233425
Nov 20236202
Dec 2023212410
Jan 202414468
Feb 202421348
Mar 2024102120
Apr 2024123327
May 202411426
Jun 2024185826
Jul 2024154322
Aug 2024227323
Sep 2024275834
Oct 2024268431
Nov 2024239823
Dec 2024155222
Jan 2025105312
Feb 2025147624
Mar 2025197527
Apr 2025298332
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 50 (4)
Journal of Nuclear Medicine Technology
Vol. 50, Issue 4
December 1, 2022
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Thyroid Scintigraphy and SPECT/CT in a Rare Case of Dual Ectopic Thyroid
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Thyroid Scintigraphy and SPECT/CT in a Rare Case of Dual Ectopic Thyroid
Sanchay Jain, Suruchi Jain, Deepa Singh
Journal of Nuclear Medicine Technology Dec 2022, 50 (4) 375-376; DOI: 10.2967/jnmt.122.264508

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Thyroid Scintigraphy and SPECT/CT in a Rare Case of Dual Ectopic Thyroid
Sanchay Jain, Suruchi Jain, Deepa Singh
Journal of Nuclear Medicine Technology Dec 2022, 50 (4) 375-376; DOI: 10.2967/jnmt.122.264508
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • CASE REPORT
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Uterine Metastasis Presenting as Abnormal Uterine Bleeding in a Case of Primary Breast Cancer Identified on 18F-FDG PET/CT
  • Differentiation of Discordant Lesions on Dual-Tracer PET/CT (68Ga-PSMA-11 and 18F-FDG) in Prostate Carcinoma: Diagnosis of Second Primary Malignancies
  • Crafting a Compelling Abstract That Gets Accepted
Show more Teaching Case Study

Similar Articles

Keywords

  • thyroid scintigraphy
  • SPECT/CT
  • dual ectopic thyroid
SNMMI

© 2025 SNMMI

Powered by HighWire