Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleIMAGING

Effects of Pacemaker, Implantable Cardioverter–Defibrillator, and Left Ventricular Leads on CT-Based Attenuation Correction

Akira Suzuki, Kichiro Koshida and Kosuke Matsubara
Journal of Nuclear Medicine Technology March 2014, 42 (1) 37-41; DOI: https://doi.org/10.2967/jnmt.113.133736
Akira Suzuki
1Diagnostic Imaging Center, Japanese Red Cross Sendai Hospital, Miyagi, Japan
2Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kichiro Koshida
3Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical, and Health Sciences, Kanazawa University, Kanazawa, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kosuke Matsubara
3Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical, and Health Sciences, Kanazawa University, Kanazawa, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 42 no. 1 37-41
DOI 
https://doi.org/10.2967/jnmt.113.133736
PubMed 
24463340

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Received for publication October 10, 2013
  • Accepted for publication November 27, 2013
  • Published online March 5, 2014.

Article Versions

  • previous version (January 24, 2014 - 05:36).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Author Information

  1. Akira Suzuki1,2,
  2. Kichiro Koshida3 and
  3. Kosuke Matsubara3
  1. 1Diagnostic Imaging Center, Japanese Red Cross Sendai Hospital, Miyagi, Japan
  2. 2Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan; and
  3. 3Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical, and Health Sciences, Kanazawa University, Kanazawa, Japan
  1. For correspondence or reprints contact: Akira Suzuki, Diagnostic Imaging Center, Japanese Red Cross Sendai Hospital, 43-3 Yagiyama Honcho 2-Chome, Sendashi, Miyagi, 982-8501 Japan. E-mail: hokumeiryou{at}hotmail.co.jp
View Full Text

Statistics from Altmetric.com

Cited By...

  • 7 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Metal artifact reduction for improving quantitative SPECT/CT imaging
    Takahiro Konishi, Takayuki Shibutani, Koichi Okuda, Hiroto Yoneyama, Riku Moribe, Masahisa Onoguchi, Kenichi Nakajima, Seigo Kinuya
    Annals of Nuclear Medicine 2021 35 3
  • Deep learning-based attenuation correction method in 99mTc-GSA SPECT/CT hepatic imaging: a phantom study
    Masahiro Miyai, Ryohei Fukui, Masahiro Nakashima, Sachiko Goto
    Radiological Physics and Technology 2024 17 1
  • Cardiac Electrophysiology: From Cell to Bedside
    Alejandro Jimenez Restrepo, Timm M. Dickfeld
    2018
  • Nuclear Cardiac Imaging
    Fabio Peroba Esteves, James R. Galt
    2015
  • A Shot to the Heart
    Andrew O. Zurick, M. Andrew Morse
    Journal of Nuclear Cardiology 2017 24 1
  • Medication and ECG Patterns That May Hinder SPECT Myocardial Perfusion Scans
    Marko Magdi Abdou Sidrak, Maria Silvia De Feo, Joana Gorica, Ferdinando Corica, Miriam Conte, Luca Filippi, Giuseppe De Vincentis, Viviana Frantellizzi
    Pharmaceuticals 2023 16 6
  • [SPECT] 4. Introductions of SPECT Reconstruction Algorithm Using the Conjugated Gradient Method and Metal Artifact Reduction Technologies in the Latest SPECT System
    Takahiro Konishi
    Japanese Journal of Radiological Technology 2022 78 8

Article usage

Article usage: January 2014 to April 2025

AbstractFullPdf
Jan 20144403
Feb 20144900
Mar 2014289512
Apr 201427519
May 201424804
Jun 201410524
Jul 20146400
Aug 20146012
Sep 20148012
Oct 20143612
Nov 20144002
Dec 20143612
Jan 20153801
Feb 20154025
Mar 201538810
Apr 20153436
May 201554713
Jun 201545104
Jul 20153697
Aug 20152131
Sep 20154066
Oct 20152113
Nov 20151897
Dec 201549127
Jan 20162186
Feb 20161553
Mar 20162069
Apr 20163492
May 2016421315
Jun 201636914
Jul 2016351321
Aug 2016191213
Sep 201641116
Oct 2016321216
Nov 2016381119
Dec 201699635
Jan 201738189
Feb 201724147
Mar 2017371116
Apr 20171979
May 20172262
Jun 2017231411
Jul 20171835
Aug 20172422
Sep 20171664
Oct 201733810
Nov 201732117
Dec 20171547
Jan 20181977
Feb 20181163
Mar 20187105
Apr 20181944
May 2018151614
Jun 2018891
Jul 201818104
Aug 20188155
Sep 20188105
Oct 20184108
Nov 201891710
Dec 201811139
Jan 2019775
Feb 201910195
Mar 20198148
Apr 2019123010
May 20194195
Jun 201911165
Jul 20198119
Aug 20193147
Sep 201915207
Oct 2019141714
Nov 201916193
Dec 20199176
Jan 20207175
Feb 202013166
Mar 20201273
Apr 20206158
May 2020345
Jun 20206117
Jul 2020370
Aug 20205100
Sep 20209192
Oct 20206138
Nov 202013144
Dec 2020283
Jan 2021372
Feb 20216185
Mar 20216203
Apr 20212195
May 20214153
Jun 202172010
Jul 202182514
Aug 2021132510
Sep 20218186
Oct 202111815
Nov 2021102815
Dec 20216409
Jan 20226377
Feb 20224318
Mar 20222216
Apr 202252911
May 202252217
Jun 20226255
Jul 20221232
Aug 20227233
Sep 20224284
Oct 20220195
Nov 202232310
Dec 20224260
Jan 20233261
Feb 20233262
Mar 20236199
Apr 20234257
May 20236265
Jun 20232121
Jul 202342413
Aug 202352510
Sep 20231101
Oct 202374115
Nov 20234255
Dec 202354215
Jan 20245722
Feb 20249345
Mar 202482029
Apr 202486710
May 20241309
Jun 20247349
Jul 202442215
Aug 202412419
Sep 2024143714
Oct 20249284
Nov 20249204
Dec 20242296
Jan 202522510
Feb 20254558
Mar 202584425
Apr 2025112824
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 42 (1)
Journal of Nuclear Medicine Technology
Vol. 42, Issue 1
March 1, 2014
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Effects of Pacemaker, Implantable Cardioverter–Defibrillator, and Left Ventricular Leads on CT-Based Attenuation Correction
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Effects of Pacemaker, Implantable Cardioverter–Defibrillator, and Left Ventricular Leads on CT-Based Attenuation Correction
Akira Suzuki, Kichiro Koshida, Kosuke Matsubara
Journal of Nuclear Medicine Technology Mar 2014, 42 (1) 37-41; DOI: 10.2967/jnmt.113.133736

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Effects of Pacemaker, Implantable Cardioverter–Defibrillator, and Left Ventricular Leads on CT-Based Attenuation Correction
Akira Suzuki, Kichiro Koshida, Kosuke Matsubara
Journal of Nuclear Medicine Technology Mar 2014, 42 (1) 37-41; DOI: 10.2967/jnmt.113.133736
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • SPECT/CT
  • CTAC
  • pacemaker
  • myocardial perfusion
SNMMI

© 2025 SNMMI

Powered by HighWire