Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

γ-Camera–Based Method for Measuring the γ-Count from 131I Capsules: An Alternative to the Thyroid Uptake Probe

Biju K. Menon, Awasare S. Uday and Baghel N. Singh
Journal of Nuclear Medicine Technology March 2018, 46 (1) 45-48; DOI: https://doi.org/10.2967/jnmt.117.198077
Biju K. Menon
Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Mumbai, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Awasare S. Uday
Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Mumbai, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Baghel N. Singh
Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Mumbai, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    Thyroid uptake probe (131I capsule in acrylic glass phantom).

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    Scatter counts 8 cm away from 0.925-MBq 131I capsule.

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    Counts for capsules arranged around center capsule.

  • FIGURE 4.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 4.

    Capsule arrangement in camera-based 131I capsule counter.

  • FIGURE 5.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 5.

    Counts vs. capsule number, by camera-based and probe-based methods.

Tables

  • Figures
    • View popup
    TABLE 1

    Scatter Count and Percentage Scatter Contribution at Different Distances in y Direction from Centered 0.925-MBq Capsule

    0.925 MBq1.85 MBq
    ROIAbove centerBelow centerAbove centerBelow center
    Center4,327 (100%)4,327 (100%)6,666 (100%)6,666 (100%)
    2 cm60 (1.38%)116 (2.6%)595 (8.9%)588 (7.1%)
    4 cm46 (1%)53 (1.22%)294 (4.4%)129 (1.9%)
    6 cm40 (1%)42 (1%)113 (1.6%)64 (0.9%)
    8 cm38 (1%)19 (0.4%)32 (0.4%)10 (0.1%)
    • ROI = region of interest.

    • View popup
    TABLE 2

    Counts and Count Ratios for Capsules Surrounding Central Capsule

    0.925-MBq capsule1.85-MBq capsule
    Capsule no.Count/100 sCount ratio*Count/100 sCount ratio*
    Center3,1396,385
    13,1110.96,3440.65
    23,1250.866,3990.86
    33,1470.706,4460.73
    43,1320.486,4230.36
    • ↵* Central capsule–to–neighbor capsule count ratio.

    • View popup
    TABLE 3

    Camera-Based Counts at Various Acquisition Times vs. Probe-Based Counts for 0.925-MBq Capsules

    Camera-based countProbe-based count
    Capsule no.100 s200 s300 s10 s
    14,6399,29713,7755,377
    24,2158,27112,3754,665
    34,2968,62712,7504,832
    44,3028,72913,3344,826
    54,9119,89514,6695,258
    64,8499,51914,1565,419
    74,3918,55712,9355,010
    84,8509,74114,5435,353
    94,6459,44714,4585,443
    103,9137,76411,6414,493
    113,7947,64411,3134,215
    125,14910,21614,9455,555
    134,4819,21513,5664,982
    144,1258,20912,4684,655
    155,28110,33815,8365,655
    Mean4,5239,03113,5185,049
    SD4348511,279428
    • View popup
    TABLE 4

    Camera-Based Counts at Various Acquisition Times vs. Probe-Based Counts for 1.85-MBq Capsules

    Camera-based countProbe-based count
    Capsule no.100 s200 s300 s10 s
    19,09618,09026,7619,790
    28,69517,70426,3449,462
    38,56717,34127,0099,562
    48,72917,14126,2009,277
    58,15016,39224,8149,109
    69,37718,65828,2719,946
    79,23218,45028,3759,904
    88,28216,52825,3209,057
    98,14116,56625,1009,068
    108,04616,32824,1648,999
    118,58817,31726,2019,288
    129,16019,21327,6209,934
    138,23016,24923,7098,975
    149,72419,09628,74210,292
    158,58017,43125,8369,273
    169,29118,16027,2719,579
    178,62917,34626,5989,395
    188,59017,35925,9019,329
    197,94915,78923,6668,978
    209,23817,78126,8489,847
    Mean8,694.6317,413.1126,209.959,453.11
    SD511.24979.931,505.46408.17
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 46 (1)
Journal of Nuclear Medicine Technology
Vol. 46, Issue 1
March 1, 2018
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
γ-Camera–Based Method for Measuring the γ-Count from 131I Capsules: An Alternative to the Thyroid Uptake Probe
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
γ-Camera–Based Method for Measuring the γ-Count from 131I Capsules: An Alternative to the Thyroid Uptake Probe
Biju K. Menon, Awasare S. Uday, Baghel N. Singh
Journal of Nuclear Medicine Technology Mar 2018, 46 (1) 45-48; DOI: 10.2967/jnmt.117.198077

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
γ-Camera–Based Method for Measuring the γ-Count from 131I Capsules: An Alternative to the Thyroid Uptake Probe
Biju K. Menon, Awasare S. Uday, Baghel N. Singh
Journal of Nuclear Medicine Technology Mar 2018, 46 (1) 45-48; DOI: 10.2967/jnmt.117.198077
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • gamma camera–based capsule counting
  • Thyroid uptake probe
  • 131I Capsule
SNMMI