Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Corneal Dose Reduction Using a Bismuth-Coated Latex Shield over the Eyes During Brain SPECT/CT

Norikazu Matsutomo, Masaaki Fukunaga, Hideo Onishi and Tomoaki Yamamoto
Journal of Nuclear Medicine Technology September 2017, 45 (3) 214-218; DOI: https://doi.org/10.2967/jnmt.117.192849
Norikazu Matsutomo
1Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masaaki Fukunaga
2Department of Radiological Technology, Kurashiki Central Hospital, Okayama, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hideo Onishi
3Program in Biological System Sciences, Graduate School of Comprehensive Scientific Research, Prefectural University of Hiroshima, Hiroshima, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tomoaki Yamamoto
1Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 45 no. 3 214-218
DOI 
https://doi.org/10.2967/jnmt.117.192849
PubMed 
28473460

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Received for publication March 11, 2017
  • Accepted for publication April 26, 2017
  • Published online September 5, 2017.

Article Versions

  • previous version (May 4, 2017 - 07:48).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2017 by the Society of Nuclear Medicine and Molecular Imaging.

Author Information

  1. Norikazu Matsutomo1,
  2. Masaaki Fukunaga2,
  3. Hideo Onishi3 and
  4. Tomoaki Yamamoto1
  1. 1Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, Tokyo, Japan
  2. 2Department of Radiological Technology, Kurashiki Central Hospital, Okayama, Japan; and
  3. 3Program in Biological System Sciences, Graduate School of Comprehensive Scientific Research, Prefectural University of Hiroshima, Hiroshima, Japan
  1. For correspondence or reprints contact: Norikazu Matsutomo, Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, A-420, 5-4-1 Shimorenjaku Mitaka-shi, Tokyo, 181-8612, Japan. E-mail: nmatsutomo{at}ks.kyorin-u.ac.jp
View Full Text

Statistics from Altmetric.com

Cited By...

  • 6 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis
    Parinaz Mehnati, Reza Malekzadeh, Mohammad Yousefi Sooteh
    Radiological Physics and Technology 2019 12 1
  • Radiation-Induced Cerebro-Ophthalmic Effects in Humans
    Konstantin N. Loganovsky, Donatella Marazziti, Pavlo A. Fedirko, Kostiantyn V. Kuts, Katerina Y. Antypchuk, Iryna V. Perchuk, Tetyana F. Babenko, Tetyana K. Loganovska, Olena O. Kolosynska, George Y. Kreinis, Marina V. Gresko, Sergii V. Masiuk, Federico Mucci, Leonid L. Zdorenko, Alessandra Della Vecchia, Natalia A. Zdanevich, Natalia A. Garkava, Raisa Y. Dorichevska, Zlata L. Vasilenko, Victor I. Kravchenko, Nataliya V. Drosdova
    Life 2020 10 4
  • Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography
    Bow Wang, Chien-Yi Ting, Cheng-Shih Lai, Yi-Shan Tsai, Fu-Ming Tsai
    BioMed Research International 2021 2021 1
  • Assessment of dose reduction and image quality by barium composite shielding in head and chest CT
    Jong-Woong Lee, Dae Cheol Kweon
    Radiation Effects and Defects in Solids 2020 175 9-10
  • REDUCING ABSORBED DOSE TO THYROID IN NECK CT EXAMINATIONS: THE EFFECTS OF SABA SHIELDING
    Valiallah Saba, Jalal Kargar Shuraki, Abdollah Valizadeh, Mohsen Zahedinia, Maziar Barkhordari
    Radiation Protection Dosimetry 2020 191 3
  • BRAIN AND EYE AS POTENTIAL TARGETS FOR IONIZING RADIATION IMPACT: PART II – RADIATION CEREBRO-OPHTALMIC EFFECTS IN CHILDREN, PERSONS EXPOSED IN UTERO, ASTRONAUTS AND INTERVENTIONAL RADIOLOGISTS
    K. Loganovsky, P. Fedirko, D. Marazziti, K. Kuts, K. Antypchuk, I. Perchuk, T. Babenko, T. Loganovska, O. Kolosynska, G. Kreinis, S. Masiuk, L. Zdorenko, N. Zdanevich, N. Garkava, R. Dorichevska, Z. Vasilenko, V. Kravchenko, N. Drosdova, Yu. Yefimova, A. Malinyak
    Проблеми радіаційної медицини та радіобіології = Problems of Radiation Medicine and Radiobiology 2021 26

Article usage

Article usage: May 2017 to April 2025

AbstractFullPdf
May 201716108
Jun 20178900
Jul 20178000
Aug 20174201
Sep 201717505
Oct 201726229
Nov 201711902
Dec 20178301
Jan 201810701
Feb 20188500
Mar 20188002
Apr 20189113
May 201819911
Jun 20186602
Jul 20187300
Aug 20186502
Sep 20185914
Oct 20184755
Nov 20185559
Dec 20184275
Jan 20195074
Feb 201960111
Mar 201952714
Apr 20193898
May 201941310
Jun 20192858
Jul 201931119
Aug 20191444
Sep 20191789
Oct 2019212012
Nov 2019351912
Dec 20191454
Jan 2020967
Feb 20201656
Mar 20203678
Apr 20202122
May 202014513
Jun 202013115
Jul 20202282
Aug 202014311
Sep 202011610
Oct 202017613
Nov 20201626
Dec 202013519
Jan 2021766
Feb 2021121315
Mar 202181913
Apr 202120136
May 20215179
Jun 2021112213
Jul 202110915
Aug 202191715
Sep 202161910
Oct 202162123
Nov 2021143718
Dec 202111209
Jan 2022102511
Feb 202272613
Mar 202251311
Apr 202211123
May 202242420
Jun 20224178
Jul 20227123
Aug 2022487
Sep 202271813
Oct 20226208
Nov 20225186
Dec 2022762
Jan 2023732
Feb 20233110
Mar 202332210
Apr 20233239
May 202381013
Jun 2023577
Jul 20236711
Aug 202341715
Sep 2023102410
Oct 20231083
Nov 2023111813
Dec 202321810
Jan 20243235
Feb 20245152
Mar 2024274
Apr 202483416
May 20243165
Jun 2024101712
Jul 20244218
Aug 2024132511
Sep 2024162726
Oct 2024172111
Nov 2024121410
Dec 20242158
Jan 20251147
Feb 2025135711
Mar 202543629
Apr 2025172618
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 45 (3)
Journal of Nuclear Medicine Technology
Vol. 45, Issue 3
September 1, 2017
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Corneal Dose Reduction Using a Bismuth-Coated Latex Shield over the Eyes During Brain SPECT/CT
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Corneal Dose Reduction Using a Bismuth-Coated Latex Shield over the Eyes During Brain SPECT/CT
Norikazu Matsutomo, Masaaki Fukunaga, Hideo Onishi, Tomoaki Yamamoto
Journal of Nuclear Medicine Technology Sep 2017, 45 (3) 214-218; DOI: 10.2967/jnmt.117.192849

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Corneal Dose Reduction Using a Bismuth-Coated Latex Shield over the Eyes During Brain SPECT/CT
Norikazu Matsutomo, Masaaki Fukunaga, Hideo Onishi, Tomoaki Yamamoto
Journal of Nuclear Medicine Technology Sep 2017, 45 (3) 214-218; DOI: 10.2967/jnmt.117.192849
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • radiation dose
  • radiation shielding
  • image quality
  • SPECT/CT
  • attenuation correction
SNMMI

© 2025 SNMMI

Powered by HighWire