Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time

Go Akamatsu, Koji Uba, Takafumi Taniguchi, Katsuhiko Mitsumoto, Akihiro Narisue, Yuji Tsutsui and Masayuki Sasaki
Journal of Nuclear Medicine Technology June 2014, 42 (2) 101-104; DOI: https://doi.org/10.2967/jnmt.114.140665
Go Akamatsu
1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
2Division of Molecular Imaging, Institute of Biomedical Research and Innovation, Kobe Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Koji Uba
3Department of Radiological Technology, Saga University Hospital, Saga, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takafumi Taniguchi
1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Katsuhiko Mitsumoto
1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Akihiro Narisue
3Department of Radiological Technology, Saga University Hospital, Saga, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuji Tsutsui
4Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masayuki Sasaki
1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 42 no. 2 101-104
DOI 
https://doi.org/10.2967/jnmt.114.140665
PubMed 
24799607

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Received for publication March 23, 2014
  • Accepted for publication April 17, 2014
  • Published online June 2, 2014.

Article Versions

  • previous version (May 5, 2014 - 05:17).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Author Information

  1. Go Akamatsu1,2,
  2. Koji Uba3,
  3. Takafumi Taniguchi1,
  4. Katsuhiko Mitsumoto1,
  5. Akihiro Narisue3,
  6. Yuji Tsutsui4 and
  7. Masayuki Sasaki1
  1. 1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  2. 2Division of Molecular Imaging, Institute of Biomedical Research and Innovation, Kobe Japan
  3. 3Department of Radiological Technology, Saga University Hospital, Saga, Japan
  4. 4Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
  1. For correspondence or reprints contact: Masayuki Sasaki, Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan. E-mail: msasaki@hs.med.kyushu-u.ac.jp
View Full Text

Statistics from Altmetric.com

Article has an altmetric score of 1

See more details

Posted by 1 X users
On 1 Facebook pages
26 readers on Mendeley

Cited By...

  • 14 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
    David F.C. Hsu, Ezgi Ilan, William T. Peterson, Jorge Uribe, Mark Lubberink, Craig S. Levin
    Journal of Nuclear Medicine 2017 58 9
  • Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
    Ivo Rausch, Agustin Ruiz, Itziar Valverde-Pascual, Jacobo Cal-González, Thomas Beyer, Ignasi Carrio
    Journal of Nuclear Medicine 2019 60 4
  • Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT
    Kei Wagatsuma, Kenta Miwa, Muneyuki Sakata, Keiichi Oda, Haruka Ono, Masashi Kameyama, Jun Toyohara, Kenji Ishii
    Physica Medica 2017 42
  • Improvement in PET/CT image quality in overweight patients with PSF and TOF
    Takafumi Taniguchi, Go Akamatsu, Yukiko Kasahara, Katsuhiko Mitsumoto, Shingo Baba, Yuji Tsutsui, Kazuhiko Himuro, Shohei Mikasa, Daisuke Kidera, Masayuki Sasaki
    Annals of Nuclear Medicine 2015 29 1
  • Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors
    Go Akamatsu, Hideaki Tashima, Yuma Iwao, Hidekatsu Wakizaka, Takamasa Maeda, Akram Mohammadi, Sodai Takyu, Munetaka Nitta, Fumihiko Nishikido, Harley Rutherford, Andrew Chacon, Mitra Safavi-Naeini, Eiji Yoshida, Taiga Yamaya
    Physics in Medicine & Biology 2019 64 9
  • Performance characteristics of silicon photomultiplier based 15-cm AFOV TOF PET/CT
    Delphine Vandendriessche, Jorge Uribe, Hugo Bertin, Frank De Geeter
    EJNMMI Physics 2019 6 1
  • Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model
    Deni Hardiansyah, Ali Asgar Attarwala, Peter Kletting, Felix M. Mottaghy, Gerhard Glatting
    Physica Medica 2017 42
  • Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma
    Chadwick L. Wright, Joseph J. Maly, Jun Zhang, Michael V. Knopp
    PET Clinics 2017 12 1
  • Evaluating and comparing the image quality and quantification accuracy of SiPM-PET/CT and PMT-PET/CT
    Yuji Tsutsui, Shinichi Awamoto, Kazuhiko Himuro, Toyoyuki Kato, Shingo Baba, Masayuki Sasaki
    Annals of Nuclear Medicine 2020 34 10
  • Discovery Molecular Imaging Digital Ready PET/CT performance evaluation according to the NEMA NU2-2012 standard
    Sofia Michopoulou, Emma O’Shaughnessy, Katharine Thomson, Matthew J. Guy
    Nuclear Medicine Communications 2019 40 3

Article usage

Article usage: May 2014 to April 2025

AbstractFullPdf
AbstractFullPdf
May 201418507
Jun 2014456625
Jul 2014419118
Aug 2014313011
Sep 201412425
Oct 20148224
Nov 20149503
Dec 20144703
Jan 20158205
Feb 20154511
Mar 20154511
Apr 20157103
May 20154611
Jun 201545812
Jul 2015821325
Aug 20155048
Sep 201551610
Oct 201510316
Nov 2015213114
Dec 20152971215
Jan 2016190712
Feb 201623866
Mar 2016216917
Apr 20163521210
May 201622667
Jun 20164951312
Jul 2016492923
Aug 2016410417
Sep 2016282919
Oct 2016281924
Nov 201630513
Dec 2016916622
Jan 2017451721
Feb 20172171918
Mar 20171231318
Apr 2017631018
May 2017871817
Jun 201717437
Jul 2017199310
Aug 2017171915
Sep 2017165211
Oct 201716998
Nov 201714874
Dec 201718782
Jan 201812812
Feb 201812783
Mar 201815858
Apr 201812178
May 201821695
Jun 2018721510
Jul 2018172173
Aug 201814693
Sep 2018109712
Oct 20189115
Nov 201810926
Dec 20189525
Jan 201915036
Feb 2019151810
Mar 2019102712
Apr 2019119221
May 2019105133
Jun 2019117212
Jul 2019147621
Aug 201998413
Sep 20196267
Oct 2019119216
Nov 201949412
Dec 201948413
Jan 20201515
Feb 2020357
Mar 20201624
Apr 202017310
May 202019011
Jun 202024613
Jul 20203342
Aug 20202544
Sep 20201245
Oct 202025214
Nov 202022412
Dec 2020512
Jan 2021449
Feb 202110918
Mar 2021198
Apr 202131013
May 202131714
Jun 20214173
Jul 202151023
Aug 20218156
Sep 2021478
Oct 202142023
Nov 202181526
Dec 202141312
Jan 202231312
Feb 202221013
Mar 202221710
Apr 2022111211
May 202271615
Jun 2022258
Jul 20222137
Aug 20225512
Sep 20224913
Oct 20221139
Nov 2022083
Dec 2022332
Jan 2023355
Feb 20232128
Mar 20233129
Apr 20233226
May 202361911
Jun 20233284
Jul 202321414
Aug 20233125
Sep 20231131
Oct 20232164
Nov 20233159
Dec 202333713
Jan 20244293
Feb 20241247
Mar 202441434
Apr 202412013
May 202412213
Jun 2024112415
Jul 202461612
Aug 202466420
Sep 2024145139
Oct 202473013
Nov 2024112810
Dec 20241225
Jan 202531614
Feb 202534110
Mar 202553715
Apr 2025155437
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 42 (2)
Journal of Nuclear Medicine Technology
Vol. 42, Issue 2
June 1, 2014
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time
Go Akamatsu, Koji Uba, Takafumi Taniguchi, Katsuhiko Mitsumoto, Akihiro Narisue, Yuji Tsutsui, Masayuki Sasaki
Journal of Nuclear Medicine Technology Jun 2014, 42 (2) 101-104; DOI: 10.2967/jnmt.114.140665
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
  • Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • axial field of view
  • time-of-flight
  • PET/CT
  • image quality
  • sensitivity
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time
Go Akamatsu, Koji Uba, Takafumi Taniguchi, Katsuhiko Mitsumoto, Akihiro Narisue, Yuji Tsutsui, Masayuki Sasaki
Journal of Nuclear Medicine Technology Jun 2014, 42 (2) 101-104; DOI: 10.2967/jnmt.114.140665

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.