Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticlePractice Management

Assessment of 99mTc-Succimer Residual Activity Using Inert Nonreactive Syringes

Wendy Galbraith, Xinlian Chen, Katie Talley and Vesper Grantham
Journal of Nuclear Medicine Technology March 2015, 43 (1) 61-63; DOI: https://doi.org/10.2967/jnmt.114.147983
Wendy Galbraith
1University of Oklahoma College of Pharmacy, Oklahoma City, Oklahoma
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Xinlian Chen
1University of Oklahoma College of Pharmacy, Oklahoma City, Oklahoma
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Katie Talley
2OU Medical Center Children’s Hospital, Oklahoma City, Oklahoma; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vesper Grantham
3College of Allied Health Department of Medical Imaging and Radiation Sciences, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

It has been widely reported that 99mTc-succimer adsorbs to plastic syringes significantly (up to 50%), often resulting in a lower administered dose than intended or inaccurate dosing. This adsorption rate is especially problematic in the pediatric population. To improve 99mTc-succimer dosing, we compared the adsorption of 99mTc-succimer with 2 types of syringes: silicone-coated syringes with nonlatex rubber on the plunger and inert nonreactive syringes with no silicone coating and no rubber on the plunger. Methods: 99mTc-succimer kits were compounded according to the manufacturer’s instructions. 99mTc-succimer doses (37–185 MBq) were drawn into 3-mL (silicone-coated or inert nonreactive) syringes in a 1-mL volume. Thirty min, 1 h, 2 h, and 4 h later, the syringes were assayed in a dose calibrator and assayed again after being emptied and rinsed with saline. In addition, we examined the data collected from 129 99mTc-succimer doses administered in a pediatric department, in which 52 were dispensed in silicone-coated syringes and 77 were dispensed in inert nonreactive syringes. The doses were assayed immediately before and after injection. The syringes were flushed with normal saline. Results: The labeling efficiency of the 99mTc-succimer kits was more than 95%. Residual activity left in the inert nonreactive syringes was 0.73% (SD, ±0.18%), which was significantly lower than the activity left in the silicone-coated syringes, 20.9% (SD, ±5.6%; P < 0.0001). The extent of adsorption did not change significantly between 30 min and 4 h of incubation. The clinical data showed that the residual activity was 30.6% (SD, ±12.5%) from doses dispensed in silicone-coated syringes and 6.38% (SD, ±2.95%) from doses dispensed in inert nonreactive syringes (P < 0.001). Conclusion: The inert nonreactive syringes had significantly less residual of 99mTc-succimer than silicone-based syringes, making it possible to accurately administer calculated doses of 99mTc-succimer to pediatric patients.

  • 99mTc-dimercaptosuccinic acid
  • succimer
  • syringe residual
  • radiopharmaceutical
  • administered activity

The adsorption or adhesion of radiopharmaceuticals to administration sets and syringes has been well documented (Table 1) (1–8). In a previous study, we found that 99mTc-succimer adsorbed to plastic syringes up to 82%, often resulting in a lower administered dose than intended or inaccurate dosing (9). This rate of adsorption is especially problematic with low doses used with the pediatric population, which led us to investigate syringes with clinically acceptable levels of adsorption.

View this table:
  • View inline
  • View popup
TABLE 1

Factors Affecting Adsorption

MATERIALS AND METHODS

99mTc-succimer kits were compounded according to the manufacturer’s instructions. 99mTc-succimer doses (37–185 MBq) were drawn into 3-mL type A, silicone-coated (BD 3 mL, 309572, B-D) and type B, inert nonreactive (Fig. 1) (HSW 3 mL, 4020-X00V0 2 mL [3 mL]) NORM-JECT (Henke Sass Wolf) syringes with a volume of 1 mL. Both syringe types are composed of a blend of laboratory-grade polyethylene and polypropylene in sterile individually wrapped packaging. Thirty min, 1 h, 2 h, and 4 h later, the syringes were assayed in a dose calibrator and assayed again after being emptied and rinsed with saline. In addition, we examined the data collected from 129 99mTc-succimer doses administered in a pediatric department located in a tertiary care academic pediatric hospital licensed for 230 inpatient beds with approximately 7,000 admissions per year serving all pediatric subspecialties. A research protocol and application was submitted to the campus institutional review board and approved. The pediatric nuclear medicine department is staffed by 4 CNMTs who shared the responsibility of administering and recording the 99mTc-succimer doses. Doses were administered using a small-bore T-port extension set with 5 mL of normal saline divided over 2 rinses through the syringe and the administration set. The activity in the syringe was assayed immediately before and after injection, with decay correction figuring into the analysis.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Inert nonreactive syringe.

RESULTS

The labeling efficiency of the 99mTc-succimer kits was more than 95%. Residual activity left in the inert nonreactive syringes (Type B) was 0.73% (SD, ±0.18%), which was significantly lower than the activity left in the silicone-coated syringes (Type A), 20.9% (SD, ±5.6%; P < 0.0001) (Table 2). The extent of adsorption did not change significantly between 30 min and 4 h of incubation. One hundred thirty-four data points were collected, with 129 included in the analysis. Of these, 52 were dispensed in Type A syringes, and 77 were dispensed in Type B syringes. The clinical data showed that the residual activity was 30.6% (SD, ±12.5%) from doses dispensed in silicone-coated syringes and 6.38% (SD, ±2.95%) from doses dispensed in inert nonreactive syringes (P < 0.001) (Table 2).

View this table:
  • View inline
  • View popup
TABLE 2

Results

DISCUSSION

This study demonstrated that syringe B had significantly less residual than syringe A. Previously with syringe A, the clinic was calculating the low pediatric doses and adding additional activity to compensate for variable adsorption loss, in which the correlation between assayed activity and administered dose was 0.94. This method of dose calculation confounded efforts to lower the recommended minimum dose and reduce the radiation burden to the patient. As a result of the study, the clinic changed the ordering procedure for the patient population, eliminating the arbitrary addition for residual loss. With syringe B, the correlation between assayed activity and administered dose was 0.99. The 5 injections not used in the analysis were from the same technologist who did not rinse the syringe during administration. Keskintepe et al. have shown that administration technique can greatly affect residual (10). In a controlled environment, the adhesion was less than 1% regardless of incubation time with the inert syringes (syringe B). In the clinic, syringe B still had a much wider range for adsorption, indicating variances with rinsing technique or difficult patient dynamics at times. The technologists did report that the new method called only for 2 rinses with normal saline versus previously using 4–5 rinses to reduce the 99mTc-succimer residual. One problem reported was from the staff pharmacists drawing the doses. There is a small learning curve to overcome the increased resistance in syringe B. In order to have a liquid-tight seal as the piston moves through the barrel, the barrel in syringe B flexes to accommodate the slightly larger diameter piston tip. Swanson et al. studied 6 syringe brands, 1 of which showed a significantly low adhesion of 5.2% ± 2.5% with 99mTc-sestamibi, and concluded that much of the adhesion appeared in the syringe barrel and the plunger, with minimal residual activity in the butterfly and tubing (1). Overall, the selection of a low-adhesion syringe gives more reproducible residual activities and reduces the dispensed activity used in clinical procedures. This type of inert nonreactive syringes with no silicone could be used for other radiopharmaceuticals with high syringe adsorption reports such as 99mTc-tetrofosmin (7) and 99mTc-sestamibi (1).

CONCLUSION

The inert nonreactive syringes had significantly less average residual than the commonly used silicone-coated syringes. This change made it possible to eliminate the arbitrary addition of activity to account for residual loss and more accurately administer desired doses in this pediatric population.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Acknowledgments

We thank Ann Kirkpatrick and the staff of the University of Oklahoma Nuclear Pharmacy and the following faculty and staff of the OU Medical Center: Dr. Leann Smith, Kim Brush, and Jean Nelson.

Footnotes

  • Published online Dec. 23, 2014.

REFERENCES

  1. 1.↵
    1. Swanson TN,
    2. Troung DT,
    3. Paulsen A,
    4. Hruska CB,
    5. O’Connor MK
    . Adsorption of 99mTc-sestamibi onto plastic syringes: evaluation of factors affecting the degree of adsorption and their impact on clinical studies. J Nucl Med Technol. 2013;41:247–252.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  2. 2.
    1. Gunasekera RD,
    2. Notghi A,
    3. Mostafa AB,
    4. Harking LK
    . Adsorption of radiopharmaceuticals to syringes leads to lower administered activity than intended. Nucl Med Commun. 2001;22:493–497.
    OpenUrlCrossRefPubMedGoogle Scholar
  3. 3.
    1. Cheng K,
    2. Ngo T
    . Stability and absorption of Tc99m sestamibi in plastic syringes. J Am Pharm Assoc. 2002;42:306.
    OpenUrlGoogle Scholar
  4. 4.
    1. Jansson BA,
    2. Goransson MB,
    3. Agren BN
    . Adsorption of some technetium-99m radiopharmaceuticals onto disposable plastic syringes. J Nucl Med Technol. 1998;26:196–199.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  5. 5.
    1. Mushtag A,
    2. Rehman TU,
    3. Mansur MS,
    4. Jehangir M
    . Adsorption of 99mTc-radiopharmaceuticals onto injection vials and syringes. J Nucl Med Technol. 2008;36:91–94.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  6. 6.
    1. Stopar TG,
    2. Socan A,
    3. Peitl PK
    . Adsorption of radiopharmaceuticals to syringes: setting up a reliable protocol for its assessment. Nucl Med Commun. 2007;28:951–955.
    OpenUrlCrossRefPubMedGoogle Scholar
  7. 7.↵
    1. Bartosch R,
    2. Granegger S,
    3. Sinzinger H
    . Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes. Eur J Nucl Med. 1998;25:1333–1335.
    OpenUrlCrossRefPubMedGoogle Scholar
  8. 8.↵
    1. Hurless LM,
    2. Graves MW,
    3. Mufti OI,
    4. Quinton TM
    . The adsorption of technetium-99m sestamibi onto three plastic syringes: an evaluation of dosage administration error. J Nucl Med. 2000;41(suppl):250P–251P.
    OpenUrlGoogle Scholar
  9. 9.↵
    1. Galbraith W,
    2. Nguyen A,
    3. Harrison DL,
    4. Chen X,
    5. Talley K
    . Evaluation of 99mTc-succimer dosing in pediatric patients. J Nucl Med Technol. 2013;41:81–84.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  10. 10.↵
    1. Keskintepe D,
    2. Ozer AY
    . Residual radioactivity in the syringes used in injection of RP and factors affecting the amount of residual radioactivity. FABAD J Pharm Sci. 2005;30:176–180.
    OpenUrlGoogle Scholar
  • Received for publication August 29, 2014.
  • Accepted for publication November 5, 2014.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 43 (1)
Journal of Nuclear Medicine Technology
Vol. 43, Issue 1
March 1, 2015
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Assessment of 99mTc-Succimer Residual Activity Using Inert Nonreactive Syringes
Wendy Galbraith, Xinlian Chen, Katie Talley, Vesper Grantham
Journal of Nuclear Medicine Technology Mar 2015, 43 (1) 61-63; DOI: 10.2967/jnmt.114.147983
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur
  • Systematic Assessment of the Adsorption of 99mTc-Radiopharmaceuticals onto Plastic Syringes
  • Google Scholar

More in this TOC Section

  • Technical Peer Review: Methods and Outcomes
  • Radioactivity Decontamination of Materials Commonly Used as Surfaces in General-Purpose Radioisotope Laboratories
Show more Practice Management

Similar Articles

  • Evaluation of 99mTc-Succimer Dosing in Pediatric Patients
  • Adsorption of Some Technetium-99m Radiopharmaceuticals onto Disposable Plastic Syringes
See more

Keywords

  • 99mTc-dimercaptosuccinic acid
  • succimer
  • syringe residual
  • radiopharmaceutical
  • administered activity
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessment of 99mTc-Succimer Residual Activity Using Inert Nonreactive Syringes
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Assessment of 99mTc-Succimer Residual Activity Using Inert Nonreactive Syringes
Wendy Galbraith, Xinlian Chen, Katie Talley, Vesper Grantham
Journal of Nuclear Medicine Technology Mar 2015, 43 (1) 61-63; DOI: 10.2967/jnmt.114.147983

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.