Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleRadiation Safety

Radiation Exposure to the Nuclear Medicine Personnel During Preparation and Handling of 213Bi-Radiopharmaceuticals

Parul Thakral, Ishita Sen, Jakub Simecek, Sebastian Marx, Jyotsna Kumari, Sunil Kumar, Pankaj Tandon, Sugandha Dureja and Vineet Pant
Journal of Nuclear Medicine Technology March 2020, 48 (1) 68-72; DOI: https://doi.org/10.2967/jnmt.119.230516
Parul Thakral
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ishita Sen
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jakub Simecek
2Research and Development, Isotope Technologies Garching GmbH, Bavaria, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastian Marx
2Research and Development, Isotope Technologies Garching GmbH, Bavaria, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jyotsna Kumari
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sunil Kumar
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pankaj Tandon
3Radiological Safety Division, Atomic Energy Regulatory Board, Mumbai, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sugandha Dureja
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vineet Pant
1Department of Nuclear Medicine, Fortis Memorial Research Institute, Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Tables

    • View popup
    TABLE 1

    Whole-Body and Extremity Radiation Dose to Radiopharmacist

    RadiopharmacistHandled activity (MBq)Procedures (n)Time per procedure (min)Dose per procedure (μSv)Extremity dose per procedure (μSv)
    Right handLeft hand
    1323 ± 451834.31 ± 2.214.47 ± 1.611.46 ± 2.637.30 ± 2.40
    2341 ± 21736.64 ± 2.546.24 ± 1.812.50 ± 2.539.20 ± 1.41
    3284 ± 401135.46 ± 2.325.56 ± 1.411.20 ± 2.708.80 ± 1.57
    • Data are mean ± SD.

    • View popup
    TABLE 2

    Whole-Body External and Extremity Dose to Injector

    Radiation workerInjected activity (MBq)Injections (n)Time per injection (min)Dose per injection (μSv)Extremity dose per injection (μSv)
    Right handLeft hand
    Physician 1268 ± 4272.66 ± 0.970.43 ± 0.531.00 ± 0.810.72 ± 0.75
    Physician 2250 ± 6064.22 ± 0.890.33 ± 0.521.75 ± 0.520.50 ± 0.55
    Physician 3235 ± 5373.12 ± 1.020.33 ± 0.521.33 ± 0.521.10 ± 0.63
    Technologist 1260 ± 3364.02 ± 0.990.26 ± 0.411.50 ± 0.540.67 ± 0.52
    Technologist 2323 ± 3252.45 ± 0.890.40 ± 0.551.52 ± 0.541.00 ± 0.71
    Technologist 3276 ± 2853.48 ± 1.050.25 ± 0.501.65 ± 0.960.75 ± 0.5
    • Data are mean ± SD.

    • View popup
    TABLE 3

    Dose to Technologist During Scanning

    TechnologistInjected activity (MBq)Patients handled (n)Total scans (n)Time per scan (min)Whole-body dose per scan (μSv)
    1287 ± 4282455.23 ± 2.962.45 ± 1.01
    2291 ± 5041257.45 ± 1.982.23 ± 0.98
    • Data are mean ± SD.

    • View popup
    TABLE 4

    Extremity Dose to Nurse During Blood Sampling

    Extremity dose per patient (μSv)
    NurseInjected activity (MBq)Patients handled (n)Time per patient*(min)Right handLeft hand
    1291 ± 42522.23 ± 1.235.5 ± 0.833.8 ± 0.74
    2284 ± 46423.67 ± 1.026.4 ± 1.334.6 ± 0.71
    • ↵* Total for 7 samples.

    • Data are mean ± SD.

    • View popup
    TABLE 5

    Dose Rates at Various Time Points and Distances from Anterior Chest of Patients

    Measured mean dose rate (μSv/h) from patient after mean injected activity of 288 MBq (7.8 mCi) (n = 12)Calculated dose rate/MBq injected (μSv/MBq⋅h)
    Time after injection (h)Distance (m)NetGrossRangeMeanRange
    00.182.5883.4460–1150.2860.19–0.36
    16.857.635.51–7.670.0230.02–0.03
    10.117.1418.255.40–320.0600.02–0.11
    10.781.610.55–1.170.0030.001–0.004
    20.14.435.251.20–6.110.0150.004–0.019
    10.571.090.46–0.680.0020.001–0.003
    40.11.232.050.55–2.100.0040.001–0.006
    10.220.930.21–0.320.00060.0003–0.0007
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 48 (1)
Journal of Nuclear Medicine Technology
Vol. 48, Issue 1
March 1, 2020
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Radiation Exposure to the Nuclear Medicine Personnel During Preparation and Handling of 213Bi-Radiopharmaceuticals
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Radiation Exposure to the Nuclear Medicine Personnel During Preparation and Handling of 213Bi-Radiopharmaceuticals
Parul Thakral, Ishita Sen, Jakub Simecek, Sebastian Marx, Jyotsna Kumari, Sunil Kumar, Pankaj Tandon, Sugandha Dureja, Vineet Pant
Journal of Nuclear Medicine Technology Mar 2020, 48 (1) 68-72; DOI: 10.2967/jnmt.119.230516

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Radiation Exposure to the Nuclear Medicine Personnel During Preparation and Handling of 213Bi-Radiopharmaceuticals
Parul Thakral, Ishita Sen, Jakub Simecek, Sebastian Marx, Jyotsna Kumari, Sunil Kumar, Pankaj Tandon, Sugandha Dureja, Vineet Pant
Journal of Nuclear Medicine Technology Mar 2020, 48 (1) 68-72; DOI: 10.2967/jnmt.119.230516
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand
  • Experiences of Nuclear Medicine Technologists Working in PET/CT Facilities in Gauteng Province, South Africa
  • Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand
Show more RADIATION SAFETY

Similar Articles

Keywords

  • α-therapy
  • 213Bi
  • targeted therapy
  • radiation safety
  • personnel monitoring
  • TAT
SNMMI

© 2025 SNMMI

Powered by HighWire