Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Utility of Scintigraphy in Assessment of Noninfectious Complications of Peritoneal Dialysis

Gagandeep Choudhary, Padma P. Manapragada, Eric Wallace and Pradeep Bhambhvani
Journal of Nuclear Medicine Technology June 2019, 47 (2) 163-168; DOI: https://doi.org/10.2967/jnmt.118.223156
Gagandeep Choudhary
1Division of Molecular Imaging and Therapeutics, Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Padma P. Manapragada
1Division of Molecular Imaging and Therapeutics, Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eric Wallace
2Division of Nephrology, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pradeep Bhambhvani
1Division of Molecular Imaging and Therapeutics, Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    Peritoneal scintigraphy study showing normal results. (A) Fifteen-minute dynamic infusion images of abdomen demonstrate progressive accumulation of tracer into peritoneal cavity, with uniform distribution. (B–E) Postinfusion anterior and posterior static images of abdomen (B and C) and chest (D and E) demonstrate no abnormal tracer collection. (F and G) Postdrainage images also demonstrate no abnormal tracer retention.

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    A 46-y-old woman on peritoneal dialysis who presented with acute shortness of breath and chest pain. (A and B) Chest radiograph (A) and axial CT scan (B) show moderate right pleural effusion. (C and D) Anterior and posterior postinfusion static images of chest demonstrate abnormal accumulation of tracer in right pleural cavity, confirming pleural–peritoneal leak.

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    A 60-y-old man with end-stage renal disease on peritoneal dialysis who presented with right scrotal swelling. (A) Postinfusion anterior static images of pelvis show abnormal bilateral accumulation of tracer (right greater than left, arrows) in the patent processus vaginalis and inguinoscrotal regions. (B) On coronal CT image, fluid (arrows) is seen in both patent processus vaginalis and right scrotum.

  • FIGURE 4.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 4.

    A 38-y-old man on peritoneal dialysis who was admitted to hospital with progressive right-sided abdominal swelling and shortness of breath. (A and B) Postinfusion anterior and posterior static images of abdomen show abnormal accumulation of tracer (arrows) in right lateral abdominal wall. (C and D) Subsequent CT and SPECT coronal images also demonstrate abnormal fluid and tracer collection (arrows) in right lateral abdominal wall, confirming abdominal wall leak.

  • FIGURE 5.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 5.

    A 38-y-old man on peritoneal dialysis who presented with mild abdominal discomfort and swelling in left lower abdominal wall. (A and B) Postinfusion planar anterior and lateral images of abdomen show focal abnormal accumulation of tracer (arrows) in left lower anterior abdominal wall. (C and D) Subsequent CT and SPECT axial images demonstrate abnormal fluid and tracer accumulation (arrows) at insertion site of abdominal wall catheter, confirming pericatheter leak. Patient was treated with reinsertion of peritoneal dialysis catheter. (E and F) Follow-up postinfusion planar anterior and lateral images demonstrate normal tracer distribution in peritoneal cavity, with resolution of pericatheter leak.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 47 (2)
Journal of Nuclear Medicine Technology
Vol. 47, Issue 2
June 1, 2019
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Utility of Scintigraphy in Assessment of Noninfectious Complications of Peritoneal Dialysis
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Utility of Scintigraphy in Assessment of Noninfectious Complications of Peritoneal Dialysis
Gagandeep Choudhary, Padma P. Manapragada, Eric Wallace, Pradeep Bhambhvani
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 163-168; DOI: 10.2967/jnmt.118.223156

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Utility of Scintigraphy in Assessment of Noninfectious Complications of Peritoneal Dialysis
Gagandeep Choudhary, Padma P. Manapragada, Eric Wallace, Pradeep Bhambhvani
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 163-168; DOI: 10.2967/jnmt.118.223156
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • INFECTIOUS COMPLICATIONS
    • NONINFECTIOUS COMPLICATIONS
    • PERITONEAL SCINTIGRAPHY IMAGING TECHNIQUE
    • ROLE OF SPECT AND SPECT/CT
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Software Discrepancies in Radionuclide-Derived Left Ventricular Ejection Fraction
Show more Imaging

Similar Articles

Keywords

  • Peritoneal Scintigraphy
  • Peritoneal Dialysis
  • Continuous Ambulatory Peritoneal Dialysis
  • Dialysis Complications
SNMMI

© 2025 SNMMI

Powered by HighWire