Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Assessing 18F-FDG Uptake in the Sentinel Lymph Node in Breast Cancer

Ismet Sarikaya and Ali Sarikaya
Journal of Nuclear Medicine Technology June 2019, 47 (2) 149-153; DOI: https://doi.org/10.2967/jnmt.118.219758
Ismet Sarikaya
1Department of Nuclear Medicine, Kuwait University Faculty of Medicine, Mubarak Al-Kabeer Hospital, Kuwait City, Kuwait; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ali Sarikaya
2Department of Nuclear Medicine, Trakya University Faculty of Medicine, Edirne, Turkey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

18F-FDG PET/CT has limited value in early breast cancer. Sentinel lymph node (SLN) biopsy is the current procedure of choice to search for small metastatic deposits in the axillary lymph nodes in early breast cancer. In this retrospective study, we reevaluated 18F-FDG PET/CT images after locating the SLN on PET/CT with the help of SLN SPECT/CT images and assessed 18F-FDG uptake, particularly in the SLN. Our goal was to understand if combined evaluation of 18F-FDG PET/CT and SLN SPECT/CT could be useful for detecting early lymph node metastasis in the axilla. Methods: 18F-FDG PET/CT images of newly diagnosed breast cancer patients who also had SLN scintigraphy (SPECT/CT) and biopsy results were analyzed to assess 18F-FDG uptake in the SLN. The SLN seen on SPECT/CT images was located on PET/CT images, and its metabolic activity was assessed both visually and semiquantitatively using SUVmax. 18F-FDG PET results were compared with the histopathology result for the SLN. Results: Twenty patients among 130 met the inclusion criteria. SLN SPECT/CT images were helpful for locating the SLN on 18F-FDG PET/CT images in all 20 patients. Histopathologic analysis of the SLNs demonstrated metastasis in 7 patients and no metastasis in 13. There was mild (visible) 18F-FDG uptake in the SLN (SUVmax, 1.2–4.1; metastatic deposit size, 6–8 mm) in 6 of 7 patients with SLN metastasis (85.7%). There was no or only faint 18F-FDG uptake in the SLN (SUVmax < 1) in 9 of 13 patients with no SLN metastasis (69.2%). Receiver-operating-characteristic curve analysis indicated that the SUVmax cutoff for differentiating SLN-positive from -negative cases was 0.85 (sensitivity, 85.7%; specificity, 61.5%; area under the curve, 0.747; P < 0.05). Conclusion: Combined evaluation of 18F-FDG PET/CT and SPECT/CT images to assess 18F-FDG uptake, particularly in the SLN, is a new image analysis technique to detect early metastatic disease in the axillary lymph nodes in breast cancer. Although this technique does not currently seem feasible for use in routine practice, mainly because of the limitations of current PET/CT technology in detecting small tumors, it is an interesting image analysis technique to be aware of for possible future use.

  • breast cancer
  • sentinel lymph node
  • 18F-FDG
  • PET/CT
  • SPECT/CT

PET/CT performed with 18F-FDG is commonly used for staging of locally advanced noninflammatory and inflammatory breast cancer (1–6). Locally advanced breast cancer (tumor > 5 cm or involving regional lymph nodes or adjacent tissues such as skin, muscle, or bones) includes clinical stages IIB, IIIA, IIIB, and IIIC. Invasive ductal carcinoma is the most common subtype of breast cancer, and invasive lobular carcinoma is the second most common (7). Invasive ductal carcinoma shows higher 18F-FDG uptake than invasive lobular carcinoma of the breast (8–10). Inflammatory breast cancer is rare but aggressive and involves rapidly proliferating tumor. Inflammatory breast cancer is classified as T4d, and the skin over the breast is reddened, warm, and thickened, termed peau d’orange (11).

18F-FDG PET/CT is not recommended for the initial assessment of patients with clinical T1 N0 (tumor < 2–3 cm with no lymph node metastasis) breast cancer (3). In early breast cancer, sentinel lymph node (SLN) biopsy is routinely used to search for occult lymph node metastasis (12,13). The SLN is the lymph node that receives initial lymphatic drainage from the tumor site. The SLN biopsy procedure includes peritumoral or periareolar radiopharmaceutical injection (with or without imaging) or blue dye injection shortly before the surgery, searching for the most radioactive lymph nodes using a handheld γ-probe or blue nodes, surgical sampling, and frozen-section evaluation of the SLN (14). If there is metastasis in the SLN in frozen sections, the surgeon proceeds with axillary dissection. Standard axillary dissection is limited to levels I and II, and at least 10 lymph nodes are removed. If there is metastatic disease in the level II nodes, level III nodes may also be removed (complete axillary dissection).

In most of the 18F-FDG PET imaging studies that are done in locally advanced breast cancer, there is regional lymph node metastasis with or without distant metastasis. In some patients, mild 18F-FDG uptake is seen in the axillary lymph nodes in addition to the primary tumor, and such findings are usually reported as negative or insignificant for lymph node metastasis. In those cases, SLN scintigraphy and biopsy are performed to localize the SLN and search for occult axillary lymph node metastasis.

In this retrospective study, we reevaluated 18F-FDG PET/CT images after locating the SLN on PET/CT with the help of SLN SPECT/CT images and assessed 18F-FDG uptake, particularly in the SLN. Our goal was to understand if combined evaluation of 18F-FDG PET/CT and SLN SPECT/CT could be useful for detecting early lymph node metastasis in the axilla.

MATERIALS AND METHODS

In this retrospective study, newly diagnosed breast cancer patients who had undergone both 18F-FDG PET/CT and SLN SPECT/CT and for whom biopsy results were available for the SLN were selected for further analysis. In all cases, SNL scintigraphy was performed after 18F-FDG PET/CT imaging had been found negative for metastatic disease. This retrospective study was approved by the Kuwait Ministry of Health.

18F-FDG PET/CT images were obtained on a Gemini time-of-flight PET/CT camera (Philips) 60 min after intravenous injection of 296 MBq (8 mCi) of 18F-FDG. Before PET image acquisition, a low-dose CT scan was obtained for attenuation correction and anatomic localization. The PET acquisition was at a rate of 3 min per bed position from the top of the head to the mid thighs. PET images were corrected for attenuation on the basis of the CT data, reconstructed using a standard iterative algorithm (ordered-subset expectation maximization), and reformatted into transaxial, coronal, and sagittal views. Maximum-intensity projections were also generated. Both attenuation-corrected and uncorrected PET images, as well as PET/CT images, were reviewed.

SLN scintigraphic images were obtained on a Discovery 670 16-slice SPECT/CT camera (GE Healthcare) after periareolar intradermal injections of 99mTc-nanocolloid at 4 sites (3-, 6-, 9-, and 12-o’clock) using a 27-G needle with a dose of 18.5–37 MBq (0.5–1.0 mCi) divided into 4 parts, each in a 0.1- to 0.2-mL volume. In our department, we first obtain dynamic images over the anterior chest/axilla, at 30 s per image for 20 min. This is followed by a static image of 5 min and a SPECT/CT acquisition at 20–25 s/projection, 120 or 128 projections over 360°, with a matrix size of 128 × 128. CT is low-dose (140 kVp and 2.5 mA).

SLNs were identified on dynamic, static, and SPECT/CT images. The SLN seen on the SPECT/CT image was located on the 18F-FDG PET/CT image, and its metabolic activity was assessed visually and using SUVmax. Whole-body 18F-FDG PET images were also reviewed to assess the primary tumor, both axilla and breasts, and the rest of the body.

The data were managed and statistically analyzed using the Statistical Package for Social Sciences, version 25.0. The mean ± SD of the 18F-FDG SUVmax of tumor-positive and -negative SLNs was calculated. The mean values were compared using the nonparametric Mann–Whitney test. A 2-tailed P value of less than 0.05 was considered statistically significant.

We also performed receiver-operating-curve (ROC) analysis to determine the optimal cutoff for SUVmax in SLN-positive and SLN-negative cases.

RESULTS

Images of 20 women (mean age, 61.2 y; range, 35–81 y) were selected for further analysis among 130 patients with newly diagnosed breast cancer. Fifteen patients had invasive ductal carcinoma, 2 had invasive lobular carcinoma, 1 had invasive mammary carcinoma, 1 had ductal carcinoma in situ, and 1 had both invasive ductal carcinoma and invasive lobular carcinoma in the same breast. There were bilateral tumors in 2 patients.

SLN scintigraphy was able to localize the SLN in all patients. The number of the SLNs detected by scintigraphy was 1 in 13 patients and 2 or more in 7 patients.

Surgery included SLN biopsy in all patients, with lumpectomy or wide local excision in 9, mastectomy in 11, and axillary dissection or clearance in 10.

SLN SPECT/CT images were helpful in locating the SLN on 18F-FDG PET/CT images in all 20 patients. Table 1 shows histologic subtype, grade, pathologic stage, 18F-FDG uptake (SUVmax) of SLN, and pathology result of SLN. SLN biopsy and histopathology demonstrated metastasis in 7 patients and no metastasis in 13 patients. There was mild visible 18F-FDG uptake in the SLN in 6 of 7 patients with SLN metastasis (SUVmax, 1.2–4.1; metastatic deposit size, 6–8 mm) (Fig. 1). In 1 patient with SLN metastasis, there was only faint 18F-FDG uptake in the SLN (SUVmax, 0.8; metastatic deposit size, 3 mm). In 4 patients with SLN metastasis, there was bilateral axillary node uptake, which was milder on the nontumoral side in 3 and equal on both sides in 1. In addition to uptake in the SLN, there was also mild 18F-FDG uptake in several other axillary nodes on the tumor side in 3 patients who had both sentinel and nonsentinel node metastatic disease on histopathology.

View this table:
  • View inline
  • View popup
TABLE 1

Histologic Subtype, Tumor Grade, Pathologic Stage, 18F-FDG Uptake in SLN, and Pathology Result

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

A 50-y-old woman with bilateral grade 2 invasive lobular carcinoma (left breast, pT3 N3a Mx; right breast, pT1c N3a Mx). (Left) SLN scintigraphic study from right breast with selected transaxial CT, SPECT/CT, and maximum-intensity-projection images demonstrates SLN in right axilla (arrows). (Middle) Selected 18F-FDG transaxial PET, CT, and PET/CT images of bilateral axillae demonstrate mild focal uptake in SLN in right axilla (SUVmax, 1.4) (arrows) and multiple mildly hypermetabolic left axillary lymph nodes (SUVmax, 2.9). Histopathologic analysis demonstrated metastasis in right SLN and bilaterally in multiple axillary lymph nodes. (Right) 18F-FDG PET whole-body maximum-intensity-projection image demonstrates bilateral diffuse uptake in breasts, focal mild tumoral uptake in left breast (SUVmax, 2.3), and bilateral mildly hypermetabolic axillary lymph nodes, more prominent on left side. Abnormal hypermetabolic activity in right lobe of thyroid is suspicious for malignancy and large myomatous uterus is also seen.

In 9 of 13 patients with no SLN metastasis on histopathology, there was no or faint 18F-FDG uptake in the SLN (SUVmax < 1) (Fig. 2). There was mild 18F-FDG uptake in the SLN in 4 of 13 patients with no SLN metastasis (SUVmax, 1.4–5.9). In a patient with prominent 18F-FDG uptake in the SLNs (SUVmax, 5.9), the SLNs were located in level III on SPECT/CT. It was not clear if axillary dissection included level III nodes in this patient. There was bilateral mild axillary uptake in 5 patients who were negative for SLN metastasis; this finding was to a similar degree on both sides in 4 patients and less intense on the nontumoral side in 1 patient.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

A 53-y-old woman with grade 1 invasive ductal carcinoma of right breast (pT1c N0(sln) Mx). (Left) SLN scintigraphic study from right breast with selected SPECT/CT and maximum-intensity-projection images demonstrates SLN in right axilla (arrows). (Middle) Selected 18F-FDG transaxial PET, CT, and PET/CT images demonstrate only faint uptake in SLN in right axilla (SUVmax, 0.7) (arrows). Mild but slightly more prominent 18F-FDG uptake is seen in contralateral left axillary lymph nodes. Histopathologic analysis demonstrated no evidence of metastasis in right SLN. (Right) 18F-FDG PET whole-body maximum-intensity-projection image demonstrates bilateral diffuse uptake in breasts and focal tumoral uptake in right breast (SUVmax, 2.1).

The mean ± SD for 18F-FDG SUVmax in SLN-positive and -negative cases was 2.06 ± 1.21 and 1.4 ± 1.35, respectively. Statistically, there was no significant difference in the values (P = 0.08).

ROC analysis indicated that the SUVmax cutoff for differentiating SLN-positive from SLN-negative cases was 0.85. The sensitivity of this value was 85.7% (95% confidence interval, 83.1−88.4), and the specificity was 61.5% (95% confidence interval, 59.7–63.6), with an area under the curve of 0.747 (P < 0.05). Figure 3 shows the ROC curve.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

ROC curve for 18F-FDG PET/CT in detecting metastasis in SLN.

There were several foci of abnormal 18F-FDG uptake in the spine that were suggestive of bone metastasis in a patient with grade 3 invasive ductal carcinoma, pathologic stage pT2 N2a Mx, and mild focal 18F-FDG uptake in the SLN and several other axillary nodes.

DISCUSSION

Detection of early metastatic disease in the regional lymph nodes is important for the selection of appropriate treatment and improving survival. SLN biopsy is the current method to search for small amounts of metastatic deposits in the axillary lymph nodes in early breast cancer. Micrometastasis includes tumors measuring 0.2–2 mm or more than 200 cells. Macrometastasis is when the tumor is larger than 2 mm. Intraoperative frozen sections of SLNs have a low sensitivity in detecting micrometastases but a reasonable sensitivity for macrometastases (15,16). 18F-FDG PET imaging can detect metastatic deposits larger than 6–8 mm.

In routine 18F-FDG PET studies, mild uptake (SUVmax < 2.5) in the axillary lymph nodes is usually reported as negative or insignificant for metastatic disease and considered to be due to inflammatory changes. In the current study, we assessed 18F-FDG PET uptake particularly in the SLN. SLN SPECT/CT images were helpful in locating the SLN and assessing 18F-FDG uptake in the SLN. SPECT/CT is becoming increasingly available, and the CT part of the study is useful to determine the exact anatomic location of the SLNs.

We did not find a statistically significant difference in 18F-FDG SUVmax between tumor-positive and tumor-negative SLNs. The absence of a difference in SUVmax between SLN-positive and SLN-negative patients was probably related to the small sample size and to the generally low uptake in lymph nodes. However, in most of our patients with SLN metastasis, there was visible mild focal uptake in the SLN (86%). Mild visible focal uptake in the SLN was seen in a lesser percentage of patients with no SLN metastasis (31%). The SUVmax of mild but visible focal uptake ranged from 1.2 to 4.1 in SLN-positive patients. In cases with faint 18F-FDG uptake in the SLN in SLN-negative patients, SUVmax was less than 1. ROC analysis showed that the SUVmax cutoff was 0.85 in differentiating SLN-positive from SLN-negative cases. However, given the small number of patients in our study, the accuracy of ROC analysis is limited. Bilateral mild axillary uptake was of equal intensity in most SLN-negative cases and was more prominent on the tumor side in SLN-positive patients. It is already well known that bilateral symmetric lymph node uptake is likely due to a benign process, such as inflammatory conditions, and asymmetric uptake is more suspected of indicating metastatic disease in oncologic cases. Mild visible focal uptake in axillary lymph nodes, if unilateral or more prominent on the tumor side, raises suspicion of early metastatic disease. If the abnormal uptake is only in the SLN but not in other nodes, this may further raise suspicion for early lymph node metastasis even if the SUVmax is less than 2.5. However, it is still difficult to decide if mild 18F-FDG uptake in the SLN is due to a small amount of metastatic disease or to inflammatory changes. SLN biopsy is still the procedure of choice to detect early metastatic disease in the SLN.

Histopathologically determined sizes of the metastatic deposits were 6–8 mm in our 6 cases with mild focal 18F-FDG uptake in the SLN. In a case with a metastatic deposit size of 3 mm, 18F-FDG PET was negative. It is well known that 18F-FDG PET imaging is limited in detecting small metastatic deposits (<6 mm). The physical size of a lesion is difficult to derive from PET images because of spill-out and partial-volume effects (17,18). The smaller the tumor, the greater the underestimation of the uptake via PET imaging (17,18). Different tumors with exactly the same uptake value or phantoms with same radioactivity concentrations in different-sized spheres show that uptake decreases when tumor or sphere size decreases (17,19). In recent years, there have been various attempts to improve small lesion detection, including time-of-flight PET cameras, PET cameras with solid-state photodetectors, digital PET, point-spread function (PSF) reconstruction, and reconstruction with smaller voxels (20–25). Recent studies have demonstrated that PSF reconstruction improves detection of small metastatic deposits in various cancers (26–29). PSF reconstruction can improve spatial resolution and signal-to-noise ratio in PET imaging (18). In breast cancer patients, PET with PSF reconstruction performed better than PET with ordered-subset expectation maximization reconstruction in detecting nodal metastases 7 mm or smaller, and the smallest detectable metastasis was 1.8 mm (26). The reconstruction of PET images with time-of-flight and PSF enabled the improvement of diagnostic performance in N-staging of breast carcinoma, even when the dose of radiopharmaceutical was reduced to 2.5 MBq/kg (27). In our cases, we used iterative or ordered-subset expectation maximization reconstruction. PSF reconstruction may help better detect 18F-FDG uptake in the SLN with a small amount of metastatic disease. PSF reconstruction improves detection of small deposits, but Munk et al. reported that PSF reconstruction artifacts can lead to misinterpretations when used for quantitative analyses of small subcentimeter lesions, which is important when monitoring treatment response on lymph nodes using SUV measurements (18).

Because of the current limitations of PET/CT imaging for detecting small tumor deposits, obtaining both 18F-FDG PET/CT and SLN SPECT/CT in early breast cancer is currently not feasible in routine use. Obtaining both images is costly and time-consuming and increases radiation dose. However, it is important to combine different techniques and imaging modalities to obtain the maximum available result for a study.

CONCLUSION

Combined evaluation of 18F-FDG PET/CT and SLN SPECT/CT images allows assessing 18F-FDG uptake, particularly in the SLN, which is important in detecting early lymph node metastasis in breast cancer. Although this technique does not seem feasible in routine practice, mainly because of the limitations of current PET/CT technology in detecting small amounts of tumor, it is an interesting image analysis technique to be aware of for possible future use.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Acknowledgments

We thank Dr. Galip Ekuklu for his help in statistical analysis.

Footnotes

  • Published online Nov. 9, 2018.

REFERENCES

  1. 1.↵
    1. Lee JH
    . Radionuclide methods for breast cancer staging. Semin Nucl Med. 2013;43:294–298.
    OpenUrl
  2. 2.
    1. Caresia Aroztegui AP,
    2. García Vicente AM,
    3. Alvarez Ruiz S,
    4. et al
    .; Oncology Task Force of the Spanish Society of Nuclear Medicine and Molecular Imaging. 18F-FDG PET/CT in breast cancer: evidence-based recommendations in initial staging. Tumour Biol. 2017;39:1010428317728285.
    OpenUrl
  3. 3.↵
    1. Groheux D,
    2. Cochet A,
    3. Humbert O,
    4. et al
    . 18F-FDG PET/CT for staging and restaging of breast cancer. J Nucl Med. 2016;57(suppl 1)17S–26S.
    OpenUrlAbstract/FREE Full Text
  4. 4.
    1. Carkaci S,
    2. Macapinlac HA,
    3. Cristofanilli M,
    4. et al
    . Retrospective study of 18F-FDG PET/CT in the diagnosis of inflammatory breast cancer: preliminary data. J Nucl Med. 2009;50:231–238.
    OpenUrlAbstract/FREE Full Text
  5. 5.
    1. Alberini JL,
    2. Lerebours F,
    3. Wartski M,
    4. et al
    . 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) imaging in the staging and prognosis of inflammatory breast cancer. Cancer. 2009;115:5038–5047.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Groheux D,
    2. Giacchetti S,
    3. Delord M,
    4. et al
    . 18F-FDG PET/CT in staging patients with locally advanced or inflammatory breast cancer: comparison to conventional staging. J Nucl Med. 2013;54:5–11.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Barroso-Sousa R,
    2. Metzger-Filho O
    . Differences between invasive lobular and invasive ductal carcinoma of the breast: results and therapeutic implications. Ther Adv Med Oncol. 2016;8:261–266.
    OpenUrlCrossRef
  8. 8.↵
    1. Avril N,
    2. Rosé CA,
    3. Schelling M,
    4. et al
    . Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: use and limitations. J Clin Oncol. 2000;18:3495–3502.
    OpenUrlAbstract/FREE Full Text
  9. 9.
    1. Gil-Rendo A,
    2. Martínez-Regueira F,
    3. Zornoza G,
    4. et al
    . Association between [18F] fluorodeoxyglucose uptake and prognostic parameters in breast cancer. Br J Surg. 2009;96:166–170.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Groheux D,
    2. Giacchetti S,
    3. Moretti J-L,
    4. et al
    . Correlation of high 18F-FDG uptake to clinical, pathological and biological prognostic factors in breast cancer. Eur J Nucl Med Mol Imaging. 2011;38:426–435.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. van Uden DJ,
    2. van Laarhoven HW,
    3. Westenberg AH,
    4. de Wilt JH,
    5. Blanken-Peeters CF
    . Inflammatory breast cancer: an overview. Crit Rev Oncol Hematol. 2015;93:116–126.
    OpenUrlCrossRef
  12. 12.↵
    1. Zahoor S,
    2. Haji A,
    3. Battoo A,
    4. et al
    . Sentinel lymph node biopsy in breast cancer: a clinical review and update. J Breast Cancer. 2017;20:217–227.
    OpenUrl
  13. 13.↵
    1. De Cicco C,
    2. Cremonesi M,
    3. Luini A,
    4. et al
    . Lymphoscintigraphy and radioguided biopsy of the sentinel axillary node in breast cancer. J Nucl Med. 1998;39:2080–2084.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Giammarile F,
    2. Alazraki N,
    3. Aarsvold JN,
    4. et al
    . The EANM and SNMMI practice guideline for lymphoscintigraphy and sentinel node localization in breast cancer. Eur J Nucl Med Mol Imaging. 2013;40:1932–1947.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Lombardi A,
    2. Nigri G,
    3. Maggi S,
    4. et al
    . Role of frozen section in sentinel lymph node biopsy for breast cancer in the era of the ACOSOG Z0011 and IBCSG 23-10 trials. Surgeon. 2018;16:232–236.
    OpenUrl
  16. 16.↵
    1. Liu LC,
    2. Lang JE,
    3. Lu Y,
    4. et al
    . Intraoperative frozen section analysis of sentinel lymph nodes in breast cancer patients: a meta-analysis and single-institution experience. Cancer. 2011;117:250–258.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Soret M,
    2. Bacharach SL,
    3. Buvat I
    . Partial-volume effect in PET tumor imaging. J Nucl Med. 2007;48:932–945.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Munk OL,
    2. Tolbod LP,
    3. Hansen SB,
    4. Bogsrud TV
    . Point-spread function reconstructed PET images of sub-centimeter lesions are not quantitative. EJNMMI Phys. 2017;4:5.
    OpenUrlCrossRef
  19. 19.↵
    1. Hoffman EJ,
    2. Huang SC,
    3. Phelps ME
    . Quantitation in positron emission computed tomography, 1: effect of object size. J Comput Assist Tomogr. 1979;3:299–308.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. van der Vos CS,
    2. Koopman D,
    3. Rijnsdorp S,
    4. et al
    . Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET. Eur J Nucl Med Mol Imaging. 2017;44:4–16.
    OpenUrl
  21. 21.
    1. Vandenberghe S,
    2. Mikhaylova E,
    3. D’Hoe E,
    4. Mollet P,
    5. Karp JS
    . Recent developments in time-of-flight PET. EJNMMI Phys. 2016;3:3.
    OpenUrlCrossRef
  22. 22.
    1. Cherry SR,
    2. Sorenson JA,
    3. Phelps ME
    . Physics in Nuclear Medicine. 4th ed. Philadelphia, PA: Elsevier/Saunders; 2012.
  23. 23.
    1. Koopman D,
    2. van Dalen JA,
    3. Lagerweij MC,
    4. et al
    . Improving the detection of small lesions using a state-of-the-art time-of-flight PET/CT system and small voxel reconstructions. J Nucl Med Technol. 2015;43:21–27.
    OpenUrlAbstract/FREE Full Text
  24. 24.
    1. Nguyen NC,
    2. Vercher-Conejero JL,
    3. Sattar A,
    4. et al
    . Image quality and diagnostic performance of a digital PET prototype in patients with oncologic diseases: initial experience and comparison with analog PET. J Nucl Med. 2015;56:1378–1385.
    OpenUrlAbstract/FREE Full Text
  25. 25.↵
    1. Slomka PJ,
    2. Pan T,
    3. Germano G
    . Recent advances and future progress in PET instrumentation. Semin Nucl Med. 2016;46:5–19.
    OpenUrl
  26. 26.↵
    1. Bellevre D,
    2. Blanc Fournier C,
    3. Switsers O,
    4. et al
    . Staging the axilla in breast cancer patients with 18F-FDG PET: how small are the metastases that we can detect with new generation clinical PET systems? Eur J Nucl Med Mol Imaging. 2014;41:1103–1112.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Ferdová E,
    2. Baxa J,
    3. Ňaršanská A,
    4. et al
    . Low-dose high-resolution 18F-FDG-PET/CT using time-of-flight and point-spread function reconstructions: a role in the detection of breast carcinoma axillary lymph node metastases. Anticancer Res. 2018;38:4145–4148.
    OpenUrlAbstract/FREE Full Text
  28. 28.
    1. Lasnon C,
    2. Hicks RJ,
    3. Beauregard JM,
    4. et al
    . Impact of point spread function reconstruction on thoracic lymph node staging with 18F-FDG PET/CT in non-small cell lung cancer. Clin Nucl Med. 2012;37:971–976.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Hotta M,
    2. Minamimoto R,
    3. Yano H,
    4. Gohda Y,
    5. Shuno Y
    . Diagnostic performance of 18F-FDG PET/CT using point spread function reconstruction on initial staging of rectal cancer: a comparison study with conventional PET/CT and pelvic MRI. Cancer Imaging. 2018;18:4.
    OpenUrl
  • Received for publication August 30, 2018.
  • Accepted for publication October 3, 2018.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 47 (2)
Journal of Nuclear Medicine Technology
Vol. 47, Issue 2
June 1, 2019
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessing 18F-FDG Uptake in the Sentinel Lymph Node in Breast Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Assessing 18F-FDG Uptake in the Sentinel Lymph Node in Breast Cancer
Ismet Sarikaya, Ali Sarikaya
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 149-153; DOI: 10.2967/jnmt.118.219758

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Assessing 18F-FDG Uptake in the Sentinel Lymph Node in Breast Cancer
Ismet Sarikaya, Ali Sarikaya
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 149-153; DOI: 10.2967/jnmt.118.219758
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Biology of Cancer and PET Imaging: Pictorial Review
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • breast cancer
  • Sentinel Lymph Node
  • 18F-FDG
  • PET/CT
  • SPECT/CT
SNMMI

© 2025 SNMMI

Powered by HighWire