Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Nononcologic Applications of PET/CT and PET/MRI in Musculoskeletal, Orthopedic, and Rheumatologic Imaging: General Considerations, Techniques, and Radiopharmaceuticals

Ali Gholamrezanezhad, Kyle Basques, Ali Batouli, Mojtaba Olyaie, George Matcuk, Abass Alavi and Hossein Jadvar
Journal of Nuclear Medicine Technology March 2018, 46 (1) 33-38; DOI: https://doi.org/10.2967/jnmt.117.198663
Ali Gholamrezanezhad
1Division of Musculoskeletal Imaging, Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California
3Division of Musculoskeletal Imaging, Department of Radiology, University Hospitals of Cleveland, Case Western Reserve University, Cleveland, Ohio
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kyle Basques
3Division of Musculoskeletal Imaging, Department of Radiology, University Hospitals of Cleveland, Case Western Reserve University, Cleveland, Ohio
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ali Batouli
4Department of Radiology, Allegheny General Hospital, Pittsburgh, Pennsylvania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mojtaba Olyaie
4Department of Radiology, Allegheny General Hospital, Pittsburgh, Pennsylvania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
George Matcuk
1Division of Musculoskeletal Imaging, Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Abass Alavi
5Division of Nuclear Medicine, Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hossein Jadvar
6Division of Nuclear Medicine, Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    67-y-old woman with bilateral breast cancer underwent 18F-NaF PET/CT for evaluation of osseous metastasis. Focus of intensely increased radiotracer uptake in right ischiopubic junction (A) corresponded to healing fracture identified on low-dose CT (B).

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    Comparison of pre- and posttreatment 68Ga-citrate PET/CT scans in patient with acute osteomyelitis. Pretreatment scan showed increased radiotracer uptake involving proximal tibia. Posttreatment scan showed no significant uptake, representing complete response to treatment. (Reprinted from (13).)

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    89Zr-rituximab PET/CT scan of patient with active rheumatoid arthritis, demonstrating increased radiotracer uptake involving left second metacarpophalangeal joint and right wrist. (Image courtesy of Dr. Conny van der Laken, Afdeling Reumatologie, VU Universitair Medisch Centrum, Amsterdam.)

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 46 (1)
Journal of Nuclear Medicine Technology
Vol. 46, Issue 1
March 1, 2018
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Nononcologic Applications of PET/CT and PET/MRI in Musculoskeletal, Orthopedic, and Rheumatologic Imaging: General Considerations, Techniques, and Radiopharmaceuticals
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Nononcologic Applications of PET/CT and PET/MRI in Musculoskeletal, Orthopedic, and Rheumatologic Imaging: General Considerations, Techniques, and Radiopharmaceuticals
Ali Gholamrezanezhad, Kyle Basques, Ali Batouli, Mojtaba Olyaie, George Matcuk, Abass Alavi, Hossein Jadvar
Journal of Nuclear Medicine Technology Mar 2018, 46 (1) 33-38; DOI: 10.2967/jnmt.117.198663

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Nononcologic Applications of PET/CT and PET/MRI in Musculoskeletal, Orthopedic, and Rheumatologic Imaging: General Considerations, Techniques, and Radiopharmaceuticals
Ali Gholamrezanezhad, Kyle Basques, Ali Batouli, Mojtaba Olyaie, George Matcuk, Abass Alavi, Hossein Jadvar
Journal of Nuclear Medicine Technology Mar 2018, 46 (1) 33-38; DOI: 10.2967/jnmt.117.198663
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • PET RADIOPHARMACEUTICALS
    • IMAGING PROTOCOL
    • QUANTITATIVE PET IMAGING
    • PET/CT VERSUS PET/MRI
    • FUTURE PERSPECTIVES
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • PET/CT
  • PET/MRI
  • Rheumatoid Arthritis
  • septic arthritis
  • Osteomyelitis
  • polymyalgia rheumatica
SNMMI

© 2025 SNMMI

Powered by HighWire