Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Permissions
    • Continuing Education
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Permissions
    • Continuing Education
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow SNMMI on Twitter
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Subscribe to JNMT RSS feeds
Review ArticleContinuing Education

Incidental Findings on Myocardial Perfusion SPECT Images

Razi Muzaffar, Osama Raslan, Fatma Ahmed, Leonard Goldfarb, Barbara Sterkel and Medhat M. Osman
Journal of Nuclear Medicine Technology September 2017, 45 (3) 175-180; DOI: https://doi.org/10.2967/jnmt.117.195487
Razi Muzaffar
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Osama Raslan
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fatma Ahmed
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Leonard Goldfarb
2Division of Nuclear Medicine, Department of Radiology, John Cochran VA Medical Center, St. Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Barbara Sterkel
2Division of Nuclear Medicine, Department of Radiology, John Cochran VA Medical Center, St. Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Medhat M. Osman
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri; and
2Division of Nuclear Medicine, Department of Radiology, John Cochran VA Medical Center, St. Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Myocardial perfusion SPECT plays a crucial role in the diagnosis of coronary artery disease, providing a noninvasive tool to monitor ischemia and infarction. The findings can have a profound impact on diagnosis and management in these patients. However, incidental noncardiac findings on myocardial perfusion SPECT images can also affect management. These noncardiac subtleties are most often detected on the rotating raw SPECT images, which are often overlooked. The intent of this pictorial essay is to illustrate several subtle noncardiac abnormalities within nuclear cardiac imaging that can have an impact on patient management and follow-up.

  • nuclear cardiology
  • SPECT
  • 99mTc-sestamibi
  • myocardial perfusion SPECT

The overall leading cause of death in the United States continues to be coronary artery disease, with costs in excess of $400 billion spent each year on cardiovascular disease alone (1). As the life expectancy of the population continues to increase, the risk that heart disease will occur at some point in a person’s lifetime increases as well. Myocardial perfusion imaging using SPECT continues to be an important noninvasive tool for clinicians to evaluate suspected or known coronary artery disease (2). However, in addition to the cardiac findings, incidental noncardiac findings can also be seen on the rotating raw SPECT images or on the CT images acquired for attenuation correction (3). These findings may lead to early diagnosis of a noncardiac condition that requires further treatment (4). Therefore, both cardiac and noncardiac findings need to be carefully evaluated.

This pictorial essay presents various noncardiac findings on myocardial perfusion SPECT/CT images. We logged cases of incidental noncardiac abnormalities, reviewed the myocardial perfusion SPECT/CT images (along with supporting images from other modalities when available), and selected those that were most interesting.

FINDINGS ON ROTATING RAW SPECT IMAGES

Lung Findings

The primary use of myocardial perfusion SPECT is for the evaluation of myocardial perfusion; however, significant information can be attained from the rotating raw SPECT images of both the heart and the surrounding structures. One example is a small pericardial effusion, which can be visualized as subtle changes surrounding the heart (Fig. 1). Another example is fetal dextrocardia, a rare condition (incidence < 1%) with various congenital abnormalities, typically found incidentally (Fig. 2) (5).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Patient who presented with chest pain and shortness of breath. Raw SPECT image shows small area of photopenia surrounding heart (arrows, left). CT image shows small pericardial effusion (arrows, right).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Patient with situs inversus who presented with chest pain. Raw SPECT image (top left) shows enlarged spleen (S) in right abdomen, and liver in left abdomen (L). Processed images (top right) show lateral wall and septum flipped from normal position as evidenced by short septum; finding is most prominent in horizontal long axis (last 2 rows of processed images). CT images (bottom left and middle) and radiograph (bottom right) show that heart (H) and major organs mirror their normal positions.

Near the heart are the lungs, for which various abnormalities can be detected on the rotating raw SPECT images. One example is chronic obstructive pulmonary disease, a debilitating condition involved in nearly 3 million deaths in 2015 (6). Although subtle, chronic obstructive pulmonary disease is recognizable as a flattening of the diaphragm on the raw images (Fig. 3). Another example is pleural effusion, which often occurs in conjunction with a variety of disease states and can be seen as an area of reduced counts (Fig. 4). This pattern of photopenia can also be seen in patients who have undergone pneumonectomy (Fig. 5).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Patient with chronic obstructive pulmonary disease. Flattening of diaphragm is seen on raw SPECT stress (arrows, left) and rest (arrow, right) images, as well as on radiograph (arrows, center).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Patient with pleural effusion. Relative photopenia in right chest cavity on raw SPECT image (arrow, left) correlates with large pleural effusion on chest radiograph (arrow, right).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Lung cancer patient who was being evaluated after undergoing left pneumonectomy. Reduced counts in left chest on raw SPECT image (arrow, left) correlate with pneumonectomy changes on CT image (arrow, right).

One of the more common and well-known incidental noncardiac findings is lung cancer, which is the leading cause of cancer death worldwide among both men and women (7). A less common form of lung cancer that may be seen on the raw images is neuroendocrine tumors such as carcinoids—rare tumors that can occur within any tissue, including the lung (Fig. 6). Although pulmonary carcinoids are a common type of neuroendocrine tumor, they comprise only 1%–2% of all lung tumors (8).

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Patient with history of carcinoid tumor who presented with chest pain. Raw SPECT image shows mass in right upper chest (arrow, top left). Contrast-enhanced CT image shows heterogeneously enhancing mass in right lung (arrow, top right). 111In-pentetreotide SPECT image shows right-chest mass (arrow, bottom left), which fuses with right-lung mass on SPECT/CT image (arrow, bottom right).

Lung cancer can be mimicked on the raw images by gastric reflux with subsequent progression to hiatal hernia, for which patients may present with chest pain (Figs. 7–9). This finding exemplifies a common hurdle in the interpretation of myocardial perfusion images—the presence of increased activity in the liver, bowel, or stomach, predominantly affecting the inferior wall—as all 99mTc-labeled myocardial perfusion agents are cleared by the liver and excreted by the biliary system into the duodenum (9). Various techniques have been used to reduce this uptake, with varying degrees of success (10). Although this drawback is usually encountered during the rest portion of the examination, it is becoming more common during the stress portion as well, because of the increased use of pharmacologic stress rather than treadmill stress (Fig. 10).

FIGURE 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7.

Patient who presented with chest pain. Raw SPECT image shows abnormal tracer accumulation in right chest (arrow, left). CT image demonstrates, in posterior right hemidiaphragm, large hernia containing nearly all of stomach (arrow, right).

FIGURE 8.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 8.

Patient with abnormal tracer accumulation posterior to heart on raw SPECT images, more pronounced at rest than at stress (arrows, top). CT image shows moderate hiatal hernia (arrow, bottom).

FIGURE 9.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 9.

Patient who presented with chest pain. Raw SPECT image shows focus of uptake in anterior abdominal wall (red arrow, top left) and linear uptake in chest (yellow arrow, top left). CT images show ventral hernia (arrow, top right), as well as large hiatal hernia (yellow arrows, bottom).

FIGURE 10.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 10.

Patient who presented with chest pain. Raw SPECT images from treadmill stress test show minimal liver activity and greater distal bowel activity at stress (arrow, top left) than at rest (arrow, top right). Raw SPECT images from pharmacologic stress test show intense liver and bowel activity both at stress (arrow, bottom left) and at rest (arrow, bottom right).

Mediastinal Findings

In addition to lung cancer, tumors of the mediastinum such as a thymoma can be seen on the rotating raw SPECT images (Fig. 11). Thymomas can be benign or malignant and account for nearly 20% of anterior mediastinal neoplasms in adults (11).

FIGURE 11.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 11.

Patient who presented with chest pain. Raw SPECT image shows round area of increased uptake in right upper chest (arrow, left). Right-mediastinum mass is seen on axial CT image (arrow, center) and coronal CT image (arrow, right). On biopsy, mass was found to be thymoma.

Breast Findings

Incidental areas of uptake on the rotating raw SPECT images have also been seen in the breast, usually because of malignancy (Fig. 12) (12,13). However, nonmalignant causes of radiotracer accumulation in the breast have also been seen. For example, gynecomastia in men—a benign proliferation of glandular tissue in the breast that is often a precursor of an underlying disease—is a common finding for various reasons (Fig. 13) (14,15). Furthermore, areas of infection within the breast may show focal radiotracer accumulation (Fig. 14).

FIGURE 12.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 12.

Female patient with recently diagnosed breast cancer who presented for preoperative risk assessment. Raw SPECT image shows large mass in left breast (arrow, left). Maximum-intensity-projection PET/CT image demonstrates large left-breast mass (arrow, right) with multiple small metastatic lymph nodes.

FIGURE 13.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 13.

Male patient with end-stage liver disease who presented for pretransplantation evaluation. Raw SPECT image shows round areas of mildly increased uptake in chest (arrows, left) correlating with gynecomastia changes on CT image (arrows, right).

FIGURE 14.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 14.

Female patient who presented with chest pain. Raw SPECT images show small areas of increased uptake bilaterally in chest (arrows). Clinical examination found abscesses bilaterally in lower breasts.

Liver Findings

Several types of liver abnormality can alter the radiotracer distribution seen on the rotating raw SPECT images. One example is nonalcoholic fatty liver disease, which affects 25%–30% of the population and can lead to cardiovascular diseases, cirrhosis, or hepatocellular cancer (16). The effects of fatty liver can be seen as an intrahepatic area of photopenia (Fig. 15). Another example is ascites, a common complication of cirrhosis (Fig. 16). If liver disease progresses to liver failure requiring liver transplantation, the heart must be evaluated before the surgery, as the prevalence of coronary artery disease in patients requiring liver transplantation ranges from 7.1% to 28%. As part of the cardiac work-up, myocardial perfusion imaging is often used in conjunction with other screening measures (17).

FIGURE 15.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 15.

Patient with fatty liver disease. Raw SPECT image shows minimal uptake in liver (arrow, left). CT image shows diffuse fatty changes throughout liver (arrow, right).

FIGURE 16.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 16.

Patient with end-stage liver disease who presented for pretransplantation evaluation. Raw SPECT image shows areas of photopenia throughout abdomen (arrows, left). CT image shows diffuse ascites surrounding liver and spleen (arrows, right).

Other Abdominal Findings

The literature has described other causes of abdominal photopenia on the rotating raw SPECT images, such as simple hepatic cysts (Fig. 17), echinococcal cysts, cholecystitis (18), and tumors (Fig. 18).

FIGURE 17.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 17.

Patient with end-stage renal disease who presented for preoperative evaluation. Raw SPECT image demonstrates relative photopenia in liver (arrow, left). CT image shows polycystic hepatic disease (arrow, right) and renal disease.

FIGURE 18.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 18.

Patient with large abdominal mass who presented for preoperative evaluation. Raw SPECT image shows large area of photopenia within abdomen (arrow, left). CT images show large intraabdominal fatty mass (arrows, middle and right), which biopsy found to be well-differentiated liposarcoma.

FINDINGS ON ATTENUATION-CORRECTION CT IMAGES

With the advancement of technology and the increased availability of SPECT/CT, many facilities perform myocardial perfusion SPECT with CT attenuation correction to improve diagnostic accuracy. This additional layer of imaging allows for the detection of innumerable findings, both benign and malignant, not apparent on the myocardial perfusion SPECT images themselves (Figs. 19–21) (3). A recent study demonstrated that nearly 70% of all myocardial perfusion SPECT/CT examinations have both minor and major extracardiac findings on the attenuation-correction CT images (19). Of the major extracardiac findings in that study, more than half (52.6%) were previously unknown. The study emphasized the value of reviewing the CT portion of the examination and shed light on the amount of information that can be obtained from one of the most commonly performed nuclear medicine examinations.

FIGURE 19.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 19.

Patient who presented with chest pain. Raw SPECT image is unremarkable (top left). CT image obtained for attenuation correction shows subcentimeter spiculated nodule in left lung base (arrow, top right). PET/CT image shows mild 18F-FDG uptake in nodule (arrows, bottom row), with SUVmax of 2.5. Biopsy was performed and found adenocarcinoma.

FIGURE 20.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 20.

Patient with history of achalasia who presented with chest pain. Raw SPECT image is unremarkable (left). CT images obtained for attenuation correction show significant esophageal dilation (arrows, middle and right), consistent with patient history.

FIGURE 21.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 21.

Various subtle abnormalities on CT images obtained for attenuation correction: small hemangioma in body of T12 (yellow arrow), subcentimeter exophytic isodensity in right kidney (red arrow), and small adenoma in left adrenal gland (green arrow).

CONCLUSION

Myocardial perfusion imaging with SPECT or SPECT/CT is a valuable tool for evaluating suspected or known coronary artery disease but can also detect and diagnose a variety of other diseases. Regardless of whether the findings are apparent or subtle, they can have a profound impact on patient management and follow-up. The detection and reporting of these subtle abnormalities often require careful inspection of both the rotating raw SPECT images and the CT images obtained for attenuation correction. Therefore, interpretation of myocardial perfusion images should not be limited to merely evaluation of the heart.

Footnotes

  • Published online Jul. 13, 2017.

  • CE Credit: For CE credit, you can access the test for this article, as well as additional JNMT CE tests, online at https://www.snmmilearningcenter.org. Complete the test online no later than September 2020. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 80% of the questions correctly to receive 1.0 CEH (continuing education hour) credit. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test.

REFERENCES

  1. 1.↵
    1. Hendrani AD,
    2. Adesiyun T,
    3. Quispe R,
    4. et al
    . Dyslipidemia management in primary prevention of cardiovascular disease: current guidelines and strategies. World J Cardiol. 2016;8:201–210.
    OpenUrl
  2. 2.↵
    1. Gimelli A,
    2. Liga R,
    3. Duce V,
    4. et al
    . Accuracy of myocardial perfusion imaging in detecting multivessel coronary artery disease: a cardiac CZT study. J Nucl Cardiol. 2017;24:689–695.
    OpenUrl
  3. 3.↵
    1. Coward J,
    2. Lawson R,
    3. Kane T,
    4. et al
    . Multi-centre analysis of incidental findings on low-resolution CT attenuation correction images. Br J Radiol. 2014;87:20130701.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Chatziioannou SN,
    2. Alfaro-Franco C,
    3. Moore WH,
    4. et al
    . The significance of incidental noncardiac findings in Tc-99m sestamibi myocardial perfusion imaging: illustrated by a case. Tex Heart Inst J. 1999;26:229–231.
    OpenUrlPubMed
  5. 5.↵
    1. Bernasconi A,
    2. Azancot A,
    3. Simpson JM,
    4. et al
    . Fetal dextrocardia: diagnosis and outcome in two tertiary centres. Heart. 2005;91:1590–1594.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    Chronic obstructive pulmonary disease (COPD): fact sheet. World Health Organization website. http://www.who.int/mediacentre/factsheets/fs315/en/. Published November 2016. Accessed June 28, 2017.
  7. 7.↵
    1. Torre LA,
    2. Siegel RL,
    3. Jemal A
    . Lung cancer statistics. Adv Exp Med Biol. 2016;893:1–19.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Hilal T
    . Current understanding and approach to well differentiated lung neuroendocrine tumors: an update on classification and management. Ther Adv Med Oncol. 2017;9:189–199.
    OpenUrl
  9. 9.↵
    1. Erdoğan Z,
    2. Silov G,
    3. Ozdal A,
    4. et al
    . Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain. Indian J Nucl Med. 2013;28:45–48.
    OpenUrl
  10. 10.↵
    1. van Dongen AJ,
    2. van Rijk PP
    . Minimizing liver, bowel, and gastric activity in myocardial perfusion SPECT. J Nucl Med. 2000;41:1315–1317.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Benveniste MF,
    2. Moran CA,
    3. Mawlawi O
    . FDG PET-CT aids in the preoperative assessment of patients with newly diagnosed thymic epithelial malignancies. J Thorac Oncol. 2013;8:502–510.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Ammar KA,
    2. Shaikh A,
    3. Anigbogu M,
    4. et al
    . Breast cancer diagnosed by stress SPECT sestamibi: the role of inverse gray-scale imaging. J Nucl Cardiol. September 1, 2016 [Epub ahead of print].
  13. 13.↵
    1. García-Talavera P,
    2. Olmos R,
    3. Sainz-Esteban A,
    4. et al
    . Evaluation by SPECT-CT of an incidental finding of a thymoma and breast cancer in a myocardial perfusion SPECT with 99mTc-MIBI. Rev Esp Med Nucl Imagen Mol. 2013;32:260–262.
    OpenUrl
  14. 14.↵
    1. Uthamalingam S,
    2. Sidhu MS,
    3. Gurm GS,
    4. et al
    . Male breast uptake of 99m-Tc sestamibi in myocardial perfusion imaging. Int J Cardiol. 2012;155:e22–e23.
    OpenUrlPubMed
  15. 15.↵
    1. Mieritz MG,
    2. Christiansen P,
    3. Jensen MB,
    4. et al
    . Gynaecomastia in 786 adult men: clinical and biochemical findings. Eur J Endocrinol. 2017;176:555–566.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Bellentani S
    . The epidemiology of non-alcoholic fatty liver disease. Liver Int. 2017;37(suppl 1):81–84.
    OpenUrl
  17. 17.↵
    1. Ye C,
    2. Saincher M,
    3. Tandon P,
    4. et al
    . Cardiac work-up protocol for liver transplant candidates: experience from a single liver transplant centre. Can J Gastroenterol. 2012;26:806–810.
    OpenUrlPubMed
  18. 18.↵
    1. Lyon J,
    2. Spaulding J,
    3. Zack PM
    . Large abdominal photopenic area on 99mTc-sestamibi myocardial perfusion imaging. J Nucl Med Technol. 2012;40:281–282.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Zadro C,
    2. Roussel N,
    3. Cassol E,
    4. et al
    . Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction. J Nucl Cardiol. March 9, 2017 [Epub ahead of print].
  • Received for publication May 2, 2017.
  • Accepted for publication May 26, 2017.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 45 (3)
Journal of Nuclear Medicine Technology
Vol. 45, Issue 3
September 1, 2017
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Incidental Findings on Myocardial Perfusion SPECT Images
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Incidental Findings on Myocardial Perfusion SPECT Images
Razi Muzaffar, Osama Raslan, Fatma Ahmed, Leonard Goldfarb, Barbara Sterkel, Medhat M. Osman
Journal of Nuclear Medicine Technology Sep 2017, 45 (3) 175-180; DOI: 10.2967/jnmt.117.195487

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Incidental Findings on Myocardial Perfusion SPECT Images
Razi Muzaffar, Osama Raslan, Fatma Ahmed, Leonard Goldfarb, Barbara Sterkel, Medhat M. Osman
Journal of Nuclear Medicine Technology Sep 2017, 45 (3) 175-180; DOI: 10.2967/jnmt.117.195487
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • FINDINGS ON ROTATING RAW SPECT IMAGES
    • FINDINGS ON ATTENUATION-CORRECTION CT IMAGES
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Assessment of Myocardial Viability Using Nuclear Medicine Imaging in Dextrocardia
  • Google Scholar

More in this TOC Section

  • SNMMI Clinical Trial Network Research Series for Technologists: Application of Good Clinical Practice to Clinical Research in Medical Imaging
  • Clinical Trials of Prostate-Specific Membrane Antigen Radiopharmaceutical Therapy
  • V/Q SPECT and SPECT/CT in Pulmonary Embolism
Show more Continuing Education

Similar Articles

Keywords

  • nuclear cardiology
  • SPECT
  • 99mTc-sestamibi
  • myocardial perfusion SPECT
SNMMI