Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Value of a Lower-Limb Immobilization Device for Optimization of SPECT/CT Image Fusion

Joana do Mar F. Machado, Marina S. Monteiro, Victor Fernandes Vieira, Jean-Aybert Collinot, John O. Prior, Lina Vieira and José A. Pires-Jorge
Journal of Nuclear Medicine Technology June 2015, 43 (2) 98-102; DOI: https://doi.org/10.2967/jnmt.114.145771
Joana do Mar F. Machado
1Haute École de Santé Vaud–Filière TRM, University of Applied Sciences and Arts Western Switzerland, Lausanne, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marina S. Monteiro
2Nuclear Medicine Department, Lausanne University Hospital, Lausanne, Switzerland; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Victor Fernandes Vieira
2Nuclear Medicine Department, Lausanne University Hospital, Lausanne, Switzerland; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jean-Aybert Collinot
2Nuclear Medicine Department, Lausanne University Hospital, Lausanne, Switzerland; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John O. Prior
2Nuclear Medicine Department, Lausanne University Hospital, Lausanne, Switzerland; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lina Vieira
3Área Científica de Medicina Nuclear, Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de Lisboa, Lisbon, Portugal
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
José A. Pires-Jorge
1Haute École de Santé Vaud–Filière TRM, University of Applied Sciences and Arts Western Switzerland, Lausanne, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    (A) Dedicated support for ankle and foot for SPECT/CT acquisitions. (B) Foot is well fixed and retains aligned position thanks to comfortable cushions.

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    The 7 anatomic landmarks used to quantify misalignment between CT and SPECT images. A = tibia; B = fibula; C = medial malleolus; D = lateral malleolus; E = insertion of the Achilles tendon; F = tuberosity of the fifth metatarsal; G = distal phalanx of great toe.

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    Example of anatomic landmark of left distal phalanx of great toe in patients with (A) and without (B) support. From left to right are shown CT, SPECT, and SPECT/CT fusion images.

  • FIGURE 4.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 4.

    Box plot showing distribution of absolute difference |SPECT–CT| (mm) in groups of patients without and with support (box represents median, and quartiles and whiskers show 10th and 90th percentiles). Dashed line is drawn at 5 mm (representing the size of a SPECT voxel), above which 32% (45/140) of measurements were larger without support and only 12% (17/140) with support (P < 0.001).

  • FIGURE 5.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 5.

    (A) Mean absolute difference |SPECT–CT| (mm) according to landmarks A–G (Fig. 2) for left and right foot without and with support. (B) Same mean absolute difference |SPECT–CT| (mm) for patients 1–10 without and with support.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 43 (2)
Journal of Nuclear Medicine Technology
Vol. 43, Issue 2
June 1, 2015
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Value of a Lower-Limb Immobilization Device for Optimization of SPECT/CT Image Fusion
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Value of a Lower-Limb Immobilization Device for Optimization of SPECT/CT Image Fusion
Joana do Mar F. Machado, Marina S. Monteiro, Victor Fernandes Vieira, Jean-Aybert Collinot, John O. Prior, Lina Vieira, José A. Pires-Jorge
Journal of Nuclear Medicine Technology Jun 2015, 43 (2) 98-102; DOI: 10.2967/jnmt.114.145771

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Value of a Lower-Limb Immobilization Device for Optimization of SPECT/CT Image Fusion
Joana do Mar F. Machado, Marina S. Monteiro, Victor Fernandes Vieira, Jean-Aybert Collinot, John O. Prior, Lina Vieira, José A. Pires-Jorge
Journal of Nuclear Medicine Technology Jun 2015, 43 (2) 98-102; DOI: 10.2967/jnmt.114.145771
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Software Discrepancies in Radionuclide-Derived Left Ventricular Ejection Fraction
Show more Imaging

Similar Articles

Keywords

  • SPECT/CT
  • misalignment
  • lower limb
  • patient motion
SNMMI

© 2025 SNMMI

Powered by HighWire