Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherCASE STUDY

Penile Implant on Bone Scan Imaging: A Case Study

Michael E. Spieth and Darcy L. Kasner
Journal of Nuclear Medicine Technology September 2002, 30 (3) 128-129;
Michael E. Spieth
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Darcy L. Kasner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

We present an unusual case of the incidental finding of a penile implant on a whole-body bone scan obtained for back pain in a patient with osteoporosis and vertebral body fractures. On 2 separate occasions, this patient underwent 3-h delayed whole-body bone scanning with 99mTc-methylene diphosphonate. The images showed acute and then subacute vertebral body fractures. On both imaging occasions, the bone scan that included the region of the implant clearly showed the penis, but visualization was better on the second scan. Penile implants have not been described in the nuclear medicine literature, and it is important to recognize the diagnostic possibilities when penile photopenia is identified.

  • penile implant
  • 99mTc-methylene diphosphonate
  • bone scan

On most bone scans, the penis is not seen. One may be able to see urinary contamination over the scrotum but not the penis itself. The penis can be seen on a gastrointestinal-bleeding scan or on other scans of tagged red blood cells, especially with arousal. We present a case of a patient with a penile implant that was incidentally noticeable during whole-body bone scanning.

CASE REPORT

In 2002, an 87-y-old man presented to our clinic with back discomfort, osteoporosis, and vertebral body compression fractures. We were asked to look for new vertebral body fractures to account for the patient’s new discomfort. Three-phase whole-body bone scanning was performed after injection of 925 MBq of 99mTc-methylene diphosphonate. Blood-flow and blood-pool images were obtained over the pelvis and lumbar spine. Three hours later, a whole-body bone scan and multiple spot-views of the pelvis were obtained. The whole-body scan showed 2 resolving vertebral body fractures at T8 and T12 but no evidence of acute fractures. Not normally identified, the penis was plainly seen on this scan (Fig. 1). The penis had peripheral activity but a cold center. Upon questioning the patient and reviewing the medical record, we found that a malleable penile prosthesis (AMS 600; American Medical Systems, Inc., Minnetonka, MN) had been implanted in 1995. The penis was not as clearly seen on a prior bone scan obtained using an identical technique and camera at another institution in July 1997 (Fig. 2). The difference in conspicuity was probably caused by an oblique penile positioning, relative to the camera, on the earlier image but a profiled positioning on the later image. No other correlative imaging studies of this body region were on file. The make and model of this implant were on record as far as the electronic medical record goes back.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Whole-body bone scan obtained in 2002 clearly shows penile implant.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Whole-body bone scan obtained in 1997 shows implant less clearly than does newer image.

DISCUSSION

Penile implants have been imaged on MRI (1,2), but we can find no literature on nuclear medicine imaging of penile implants. In summary, we report a rare case of the incidental finding of a penile implant on a whole-body bone scan. The implant was probably seen because of the extreme difference between its nearly complete absence of activity and the amount of activity in normal soft tissues. The differential diagnosis is limited to implant or infarct, such as in sickle cell disease secondary to fibrosis (3). The history was consistent with a surgically placed penile implant.

Acknowledgments

The authors thank Diana Spieth for processing the illustrations and Alice Stargardt, Marshfield Medical Research and Education Foundation, for helping to prepare the manuscript.

Footnotes

  • For correspondence or reprints contact: Michael E. Spieth, MD, Department of Radiology, Marshfield Clinic, 1000 N. Oak Ave., Marshfield, WI 54449.

    E-mail: spiethm{at}mfldclin.edu

REFERENCES

  1. ↵
    Levin MF, Munk PL, Vellet AD, Chin JL. Self-contained, inflatable penile prosthesis: magnetic resonance appearance. Australas Radiol. 1994;38:51–53.
    OpenUrlPubMed
  2. ↵
    Moncada I, Hernandez C, Jara J, et al. Buckling of cylinders may cause prolonged penile pain after prosthesis implantation: a case control study using magnetic resonance imaging of the penis. J Urol. 1998;160:67–71.
    OpenUrlCrossRefPubMed
  3. ↵
    Monga M, Broderick GA, Hellstrom WJ. Priapism in sickle cell disease: the case for early implantation of the penile prosthesis. Eur Urol. 1996;30:54–59.
    OpenUrlPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 30 (3)
Journal of Nuclear Medicine Technology
Vol. 30, Issue 3
September 1, 2002
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Penile Implant on Bone Scan Imaging: A Case Study
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Penile Implant on Bone Scan Imaging: A Case Study
Michael E. Spieth, Darcy L. Kasner
Journal of Nuclear Medicine Technology Sep 2002, 30 (3) 128-129;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Penile Implant on Bone Scan Imaging: A Case Study
Michael E. Spieth, Darcy L. Kasner
Journal of Nuclear Medicine Technology Sep 2002, 30 (3) 128-129;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • CASE REPORT
    • DISCUSSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • 18F-FDG PET Hemispheric Cerebral Hypometabolic Activity: Patient Motion Artifact
  • Importance of Gated Imaging in Both Phases of Myocardial Perfusion SPECT: Myocardial Stunning After Dipyridamole Infusion
Show more CASE STUDY

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire