Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Review ArticleTeaching Case Studies

Metastatic Osseous Disease Masquerading as Infection, Diagnosed on Bone Scintigraphy and SPECT/CT

Gracie A. Keown, Sunderarajan Jayaraman and Jennifer Davidson
Journal of Nuclear Medicine Technology June 2020, 48 (2) 179-180; DOI: https://doi.org/10.2967/jnmt.119.232850
Gracie A. Keown
Nuclear Medicine Department, Auckland City Hospital, Auckland District Health Board, Grafton, Auckland, New Zealand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sunderarajan Jayaraman
Nuclear Medicine Department, Auckland City Hospital, Auckland District Health Board, Grafton, Auckland, New Zealand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jennifer Davidson
Nuclear Medicine Department, Auckland City Hospital, Auckland District Health Board, Grafton, Auckland, New Zealand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

We present a 72-y-old woman with an osseous metastasis to the spine that had an atypical appearance on both nuclear medicine and radiologic modalities and was misdiagnosed as an abscess. We discuss the pitfalls of bone scintigraphy and the causes of photopenic metastatic lesions.

  • bone
  • scintigraphy
  • metastases
  • photopenic

Despite its low specificity, bone scintigraphy is one of the most commonly ordered tests in the investigation of suspected skeletal metastases (1). Sclerotic metastases are typically radiopharmaceutical-avid on bone scintigraphy and on SPECT/CT. Metastases may show bone destruction or an extraosseous soft-tissue component (2). This is a case report of an atypical metastasis that was not avid on bone scans and had a large cystic component causing diagnostic uncertainty.

CASE REPORT

A 72-y-old woman presented with back pain and right-leg radiculopathy. Her past medical history included spindle-cell sarcoma of the left thigh treated with radiotherapy and surgery 1 y beforehand.

Contrast-enhanced CT demonstrated a ring-enhancing lesion involving the posterior elements of the right L4 vertebra, with a soft-tissue component extending into the neural foramen and spinal canal.

On MRI, the lesion was of a uniformly low T1 signal. The T2 signal was mixed, with fluid–fluid levels, consistent with intralesional hemorrhage. After gadolinium contrast administration, there was peripheral enhancement and central nonenhancement (Fig. 1).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

T1-weighted contrast-enhanced axial MR image through the lesion demonstrates central nonenhancement. The appearance was initially interpreted as collection; hence, infection was the initially proposed diagnosis.

The patient was afebrile, with a normal white cell count; however, C-reactive protein levels rose from 12 to 175 mg/L. The differential diagnosis was metastatic deposit versus infection.

Ultrasound-guided fine-needle aspiration was performed, and histologic examination revealed large numbers of neutrophils and other inflammatory cells, with no malignant cells, diagnostic of a paraspinal abscess.

Despite these results, there was ongoing concern and bone scintigraphy was performed. Whole-body imaging did not show any uptake of 99mTc-methylene diphosphonate (99mTc-MDP) tracer within the lesion (Fig. 2).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Whole-body bone scan demonstrating areas of uptake within the lumbar spine secondary to degenerative change but no tracer uptake in the metastatic lesion. Asymmetric uptake in the left lower limb is due to previous surgery, radiotherapy, and altered biomechanics.

The SPECT/CT images showed bony destruction of the right L4 pedicle, a typical location for a metastasis (Fig. 3). Nuclear medicine findings played an important role by identifying the photopenic lesion associated with lysis and remaining suggestive despite the apparent false-negative whole-body study. This prompted CT-guided core biopsy. Histologic examination revealed malignant spindle cells with marked nuclear atypia and extensive necrosis, consistent with metastatic sarcoma. The patient proceeded with palliative radiotherapy.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

SPECT/CT 3 h after intravenous administration of 99mTc MDP. (A) Images showing that lesion is photopenic; however, soft-tissue mass and associated lysis of right L4 pedicle are evident: sagittal soft-tissue reformat, unenhanced CT (top left); maximum-intensity projection of SPECT/CT (top right); sagittal soft-tissue SPECT/CT (bottom left); axial SPECT acquisition at L4 level (bottom right). (B) Images giving both structural and functional information: axial and coronal bone window CT acquisition (top); axial and coronal bone window SPECT/CT (bottom). (C) images demonstrating extensive soft-tissue involvement of L4 and confirming diagnosis of metastatic sarcoma: axial and coronal CT soft-tissue reformats (top); axial and coronal SPECT/CT (bottom).

DISCUSSION

Bone scans are frequently used to diagnose osseous metastases, with high sensitivity rates of 95% (3). However, lesions can be photopenic, and the interpreter must be aware of the causes for this. In our case, the highly aggressive, lytic nature of the lesion was the likely cause. For aggressive tumors such as this, 18F-FDG PET/CT can play a complementary role and is indicated in staging for various types of sarcomas. Other photopenic osteolytic tumors include hepatocellular, renal, thyroid carcinoma, and tumors that are confined to the bone marrow such as myeloma and lymphoma (4).

The case highlights the importance of SPECT/CT as an adjunct to whole-body imaging, as the CT component adds significant information toward the overall diagnosis. The case also emphasizes the importance of a thorough review of prior cross-sectional imaging.

A final teaching point this case highlights is the sampling error inherent in fine-needle aspiration. Core biopsy should always be preferentially obtained for conclusive histologic results.

CONCLUSION

Metastatic osseous disease is frequently investigated with bone scintigraphy. It is important for staff involved in nuclear medicine to be aware of potential pitfalls and causes of false-negative whole-body imaging. Correlation with SPECT/CT is crucial for detection of associated features of malignancy, particularly in unusual cases.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Dec. 6, 2019.

REFERENCES

  1. 1.↵
    1. Carmona Echeverria LM,
    2. Drudge-Coates L,
    3. Wilkins CJ,
    4. et al
    . Bone scan is of doubtful value as a first staging test in the primary presentation of prostate cancer. ISRN Oncol. 2012;2012:585017.
    OpenUrl
  2. 2.↵
    1. Christian PE,
    2. Waterstram-Rich KM
    . Nuclear Medicine and PET/CT. 7th ed. St Louis, MO: Elsevier Mosby; 2012.
  3. 3.↵
    1. Ziessman HA,
    2. O’Malley JP,
    3. Thrall JH,
    4. et al
    . Nuclear Medicine: The Requisites. 4th ed. Philadelphia, PA: Elsevier Saunders; 2014.
  4. 4.↵
    1. Sohaib SA,
    2. Cook G,
    3. Allen SD,
    4. et al
    . Comparison of whole-body MRI and bone scintigraphy in the detection of bone metastases in renal cancer. Br J Radiol. 2009;82:632–639.
    OpenUrlAbstract/FREE Full Text
  • Received for publication July 31, 2019.
  • Accepted for publication October 16, 2019.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 48 (2)
Journal of Nuclear Medicine Technology
Vol. 48, Issue 2
June 1, 2020
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Metastatic Osseous Disease Masquerading as Infection, Diagnosed on Bone Scintigraphy and SPECT/CT
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Metastatic Osseous Disease Masquerading as Infection, Diagnosed on Bone Scintigraphy and SPECT/CT
Gracie A. Keown, Sunderarajan Jayaraman, Jennifer Davidson
Journal of Nuclear Medicine Technology Jun 2020, 48 (2) 179-180; DOI: 10.2967/jnmt.119.232850

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Metastatic Osseous Disease Masquerading as Infection, Diagnosed on Bone Scintigraphy and SPECT/CT
Gracie A. Keown, Sunderarajan Jayaraman, Jennifer Davidson
Journal of Nuclear Medicine Technology Jun 2020, 48 (2) 179-180; DOI: 10.2967/jnmt.119.232850
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • CASE REPORT
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • High-Sensitivity Troponin Elevation in a Young Woman with Typical Chest Pain: The Heart of the Matter
  • Pulmonary Adenocarcinoma Revealed by Parathyroid Scintigraphy: An Incidental Case to Remember
  • Prominent Right Ventricular Tracer Uptake: A Harbinger of Multivessel Coronary Artery Disease
Show more Teaching Case Studies

Similar Articles

Keywords

  • bone
  • scintigraphy
  • metastases
  • photopenic
SNMMI

© 2025 SNMMI

Powered by HighWire