Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleIMAGING

Parathyroid Imaging and Localization Using SPECT/CT: Initial Results

Ana Vaz and Marc Griffiths
Journal of Nuclear Medicine Technology September 2011, 39 (3) 195-200; DOI: https://doi.org/10.2967/jnmt.110.085522
Ana Vaz
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marc Griffiths
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Primary hyperparathyroidism is caused by a single parathyroid adenoma in up to 90% of clinical cases. Selective surgical excision of the hyperfunctioning parathyroid gland is the treatment of choice for this condition, and parathyroid scintigraphy is one of the primary and standard methods used for preoperative localization. SPECT/CT is advantageous over planar imaging because SPECT/CT provides useful anatomic information, improving overall diagnostic confidence. This paper evaluates the initial findings of a hybrid parathyroid imaging technique that was put into effect after the installation of a SPECT/CT system in the nuclear medicine department at Torbay Hospital, Torquay, United Kingdom. The key findings from 3 of the initial sets of patient studies are discussed, along with the key learning points after the introduction of this new clinical service. Methods: From January 2009 until December 2009, 9 patients underwent a parathyroid study at Torbay Hospital (8 women [87.5%] and 1 man [12.5%]; mean age [±SD], 61 ± 10.12 y). All patients were referred from the endocrinology department because they had clinical signs of parathyroid adenoma (67%) or required preoperative localization of parathyroid adenoma (33%). For parathyroid scintigraphy, 640–990 MBq of 99mTc-sestamibi were administrated intravenously. A SPECT/CT system was used to acquire images from the level of the submandibular glands through the basal third of the heart. Three sets of images were acquired, and the processed images were reviewed for quality, attenuation correction, and registration. Results: Two (22%) of the 9 studies were negative for possible adenoma, and 7 (78%) were positive. Of the positive studies, 6 (86%) showed an adenoma on the left inferior gland and only 1 (14%) showed an adenoma in an eccentric position. Conclusion: The introduction of parathyroid SPECT/CT has resulted in the development of new imaging and processing protocols within our nuclear medicine department. Introducing any new technique requires knowledge, understanding, and practical skills. The additional information gained from the parathyroid SPECT/CT technique has provided new skills for practitioners and increased reporting confidence for physicians.

  • SPECT/CT
  • parathyroid scintigraphy
  • adenoma
  • hyperparathyroidism

The emergence of transmission imaging technologies within hybrid imaging systems can be used in conjunction with SPECT techniques to help localize lesions identified within traditional nuclear medicine procedures. This approach has particular value when there are limited or no anatomic landmarks present on SPECT or when such landmarks are present but greater anatomic spatial resolution is required. The successful registration of SPECT with CT for localization purposes may aid definitive diagnosis and provide more precise lesion localization as part of surgical work-up for parathyroid adenomas. The parathyroid glands are small lentil-shaped glands that generally are located adjacent to the thyroid gland. Normal parathyroid glands measure approximately 6 mm in length, 3–4 mm in transverse diameter, and 1–2 mm in anteroposterior diameter and weigh 29.5 mg ± 17.8 (mean ± SD) (1–4).

Normally, there are 2 superior and 2 inferior parathyroid glands located within the visceral space of the neck, posterior to the thyroid glands, near the tracheoesophageal groove. They may be either inside or outside the thyroid capsule (1,2).

Ectopic inferior parathyroid glands may be located in the neck, inferior to the lower pole of thyroid lobe, either in the thyrothymic ligament or associated with the cervical portion of the thymus (26%); on or adjacent to the posterior aspect of the middle third of the thyroid lobe (7%); in the anterior mediastinum (4%–5%); within the thyroid (<3%); or along the carotid sheath (<1%) (2).

Hyperparathyroidism occurs with a frequency of about 0.5 per 1,000 people, with approximately half the cases being asymptomatic and detected by serum calcium screening. Those with symptoms may have recurring low phosphate levels, weakness, fatigue, and bone pain (1–4).

Because of the small size and the location of the normal parathyroid glands, imaging with most modalities is difficult. Between 80% and 85% of parathyroid adenomas are adjacent to the thyroid (5–7). The rest are ectopically placed and may be in the anterior or posterior superior mediastinum, within or next to the thymus, along the esophagus, along the carotid sheath, or even at the carotid bifurcation. This variation causes 5% of hyperfunctional parathyroid lesions to be missed at the initial surgical procedure, but hyperfunctioning glands can be imaged using nuclear medicine techniques (1,3,8–14).

99mTc-sestamibi is the radiopharmaceutical of choice for imaging hyperplastic parathyroid glands and adenomas because of its good energy characteristics for imaging and its avid localization in the mitochondria of parathyroid tissue. 99mTc-sestamibi has yielded sensitivity rates of about 90% in primary hyperparathyroidism (1–3,15–28).

With this method, 900 MBq are administered intravenously, and planar images are acquired at 15 min and at 1.0–3 h after injection. (1–3,15–28). 99mTc-sestamibi initially concentrates in normal thyroid tissue, thyroid adenomas, parathyroid adenomas, and hyperplastic parathyroid glands. Activity in the normal thyroid tissue significantly decreases with time. Thyroid adenomas and hyperplastic parathyroid glands initially have more intense activity than does the thyroid, and the intensity typically fades with time. Most parathyroid adenomas are more intense than is the thyroid on the early images and retain much of their activity on the delayed images, becoming more visible. Most parathyroid adenomas larger than 500 mg can be detected with parathyroid scanning. Some thyroid adenomas may not fade as much as expected on delayed images, and some parathyroid adenomas may behave atypically by fading on delayed images. If delayed 99mTc-sestamibi images are inconclusive in either of these respects, it may be helpful to administer 99mTc-pertechnetate to see if the equivocal focus hyperconcentrates pertechnetate, as it will be likely to represent a thyroid adenoma (17,18).

Parathyroid imaging is especially useful in patients with negative findings on neck exploration and recurrent or persistent hypercalcemia, but the technique is still unable to image hyperplastic or normal parathyroid glands consistently. The use of SPECT increases the sensitivity of planar examinations because it allows 3-dimensional imaging of the parathyroid gland. Especially when combined with CT, SPECT becomes particularly helpful for preoperative localization of eutopic and ectopic parathyroid adenomas (1–3,15–28).

Many surgeons routinely use ultrasound, radionuclide parathyroid imaging, or both before surgery, and scintigraphy is also useful for locating the adenoma during surgery (1–3,15–28).

The primary goal of image interpretation is to detect and localize the hyperfunctioning gland. A diagnosis of parathyroid adenoma is confirmed by inspecting both the early images and the delayed images (Fig. 1). The scintigraphic patterns observed on early-phase images depend on the relative anatomic positions and radiopharmaceutical uptake of the parathyroid and thyroid glands (15,16,20,22,27).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Early phase (A) and delayed phase (B) of planar 99mTc-sestamibi scan showing normal parathyroid findings.

Additional information may be obtained from the extent of radiopharmaceutical washout from the thyroid and parathyroid glands on delayed SPECT/CT images. There are 2 patterns of washout from the parathyroid glands: delayed washout (parathyroid gland retention of radiopharmaceutical on delayed images, usually accompanied by normal washout from the thyroid) and early washout (minimal or no retention of the radiotracer in the parathyroid gland on delayed-phase images; less common, although not rare) (20,22,27).

Although the superior or inferior origin of a parathyroid gland often can be determined by its location, an enlarged gland may migrate and be seen in scintigraphic images at the level of the thyroid gland (1–3,15–28).

The most frequent cause of a false-positive finding of a hyperfunctioning parathyroid gland on scintigraphy is the solid nodule that occurs in a solitary thyroid adenoma or a multinodular goiter (Fig. 2). Benign or malignant tumors that take up the radiopharmaceutical and result in false-positive findings include breast, lung, and head and neck carcinomas and their lymph node and osseous metastases, as well as bronchial carcinoids. Within the neck, delayed washout of 99mTc-sestamibi has been described in differentiated thyroid malignancies, primary thyroid lymphomas, cervical lymph node metastasis from papillary thyroid carcinoma, reactive lymph nodes, a remnant thymus, a parathyroid hormone–secreting paraganglioma, and an enlarged submandibular salivary gland. However, in the clinical setting of hyperparathyroidism, false-positive findings are uncommon (1,20–22).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) SPECT/CT image showing possible adenoma, but thyroid uptake creates difficulty. (B) Misregistration, which may have resulted from patient movement between SPECT and CT acquisitions. This study was subsequently reprocessed. A color version of this figure is available as a supplemental file at http://tech.snmjournals.org.

The factor most commonly reported to correlate with false-negative findings is the size of the parathyroid gland (i.e., smaller glands are less likely to be detected than larger glands (16,20,22)), and inclusion of anatomic information may benefit patient treatment. SPECT/CT is particularly useful for equivocal cases or when uniglandular disease has been undetected with ultrasound techniques (29,30).

The objectives of this study were to collect the data of all patients who underwent a parathyroid study at Torbay Hospital, Torquay, United Kingdom, in 2009; list all relevant information; discuss the results; and highlight the key aspects of introducing parathyroid SPECT/CT as a new clinical service.

MATERIALS AND METHODS

Between January 2009 and December 2009, 9 patients underwent parathyroid scintigraphy in the Nuclear Medicine Department at Torbay Hospital. The patients included 8 women (87.5%) and 1 man (12.5%) and had a mean age (±SD) of 61 ± 10.12 y (Table 1). All were referred by the endocrinology department for investigation of clinical signs of parathyroid adenoma (67%) or for preoperative localization of parathyroid adenoma (33%). Appropriate ethical approval was obtained from the department to access patients’ information, acquired data, study results, and sample images. All patients consented to having their data used for research or training purposes.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Data

For parathyroid scintigraphy, the patients received 99mTc-sestamibi intravenously (mean dose, 815 MBq; range, 640–990 MBq). A SPECT/CT system (Symbia T2; Siemens) was used to acquire images from the level of the submandibular glands through the basal third of the heart. Three sets of images were acquired, the first at 10 min after injection (a 600-s static image with a 256 × 256 matrix and a zoom factor of 2.0) and the second at 90 min after injection (same parameters as before), followed by a SPECT/CT study.

The SPECT data acquisition comprised counts from the 15% energy windows at 140 keV, acquired into a 128 × 128 matrix, leading to a pixel size of 4.6 × 4.6 mm. A total of 64 frames, 30 s per frame, was acquired over a 360° orbit. The camera heads were configured with high-resolution low-energy parallel-hole collimators. Reconstruction was performed iteratively using 3-dimensional ordered-subsets expectation maximization with 4 iterations and 8 subsets. Images were smoothed with a 3-dimensional spatial gaussian filter (10 mm in full width at half maximum).

The CT parameters included a 130-kVp tube, a 0.8-s rotation time, and a 2 × 2.5 collimation. An image reconstruction algorithm (B80 reconstruction kernel) was applied, resulting in images with a slice thickness of 3 mm for a 1.5-mm reconstruction increment. The processed SPECT and CT images were reviewed for adequacy of quality, attenuation correction, registration, and fusion.

RESULTS

Two (22%) of the 9 studies were negative for possible adenoma, and 7 (78%) were positive. Of the positive studies, 6 (86%) showed an adenoma on the left inferior gland and only 1 (14%) showed an adenoma in an eccentric position.

SPECT/CT was performed in only 8 of the 9 examinations because the washout images of 1 patient were unambiguous about the presence of adenoma (Fig. 3).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Adenoma in left inferior gland, visible in delayed phase of planar 99mTc-sestamibi scan.

The following 3 cases are examples from the study population.

Case 1, a 66-y-old woman, presented with hypercalcemia possibly secondary to primary hyperparathyroidism. The endocrinology department had requested a parathyroid scan to assess parathyroid function before surgery. A 952-MBq dose of 99mTc-sestamibi was intravenously administered before the examination. The scan helped to confirm the presence of a parathyroid adenoma in the left inferior gland (Figs. 4 and 5).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Early phase (A) and delayed phase (B) of planar 99mTc-sestamibi scan showing high uptake in parathyroid, consistent with adenoma.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Transverse (A), fused coronal (B), and fused sagittal (C) SPECT/CT images showing higher uptake in neck, consistent with parathyroid adenoma, which helped to support information given by planar scan. A color version of this figure is available as a supplemental file at http://tech.snmjournals.org.

Case 2, a 49-y-old woman, was referred to investigate possible hyperparathyroidism. She was injected with 719 MBq of 99mTc-sestamibi. Focal increased uptake, persisting on the delayed images, was seen in the inferior aspect of the left thyroid lobe (Fig. 6). A corresponding finding could be seen posteriorly on the CT images (Fig. 7). The results were in keeping with a parathyroid adenoma.

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Early phase (A) and delayed phase (B) of planar 99mTc-sestamibi scan showing high-uptake area on left side of neck consistent with parathyroid adenoma.

FIGURE 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7.

In same patient as in Figure 6, SPECT/CT coronal (A) and transverse (B) images that helped to confirm position of adenoma. Both images show high-uptake area consistent with parathyroid adenoma. A color version of this figure is available as a supplemental file at http://tech.snmjournals.org.

Case 3, a 71-y-old woman, had presented to the endocrinology department with a clinically multinodular goiter and primary hyperparathyroidism. The scan had been requested to assess the dominant gland and to assess thyroid uptake. The patient was injected with 755 MBq of 99mTc-sestamibi before undergoing scanning. The scan showed the thyroid to be enlarged and heterogeneous, making assessment for a parathyroid adenoma difficult. A focus of slightly more intense uptake that was seen posterior to the lower pole of the left lobe of the thyroid could equally have represented either a parathyroid adenoma or a thyroid nodule (Figs. 8 and 9). Because the scan was ambiguous, the patient was then referred for a thyroid scan with 99mTc-pertechnetate. For this scan, 70 MBq of 99mTcO4− were administered intravenously, followed by a planar study. The thyroid gland seemed to be enlarged and contained uneven nodular uptake but no dominant nodule (Fig. 10).

FIGURE 8.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 8.

Early phase (A) and delayed phase (B) of planar 99mTc-sestamibi scan showing irregular uptake within thyroid gland.

FIGURE 9.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 9.

Coronal (A), transverse (B), and sagittal (C) SPECT/CT images showing uptake within neck area. Even though fused images helped with anatomic localization, disease within parathyroid gland could not be excluded. A color version of this figure is available as a supplemental file at http://tech.snmjournals.org.

FIGURE 10.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 10.

Planar 99mTc-sestamibi scan showing uneven thyroid uptake on 600-s anterior view. Scan was acquired 20 min after injection. Matrix is 128 × 128, and magnification is 2.0.

DISCUSSION

SPECT/CT in the management of parathyroid adenomas has the potential to improve accuracy rates and further inform subsequent surgical decisions (30). The introduction of a new hybrid imaging system and the development of a new clinical service has created opportunities for the practitioners to learn new skills, which include optimal and safe use of transmission imaging techniques, CT-based processing algorithms, patient-positioning considerations for hybrid imaging, and personal dose monitoring. Introducing new technology and techniques within an established clinical environment can affect workforce dynamics and efficiency rates (31).

The inclusion of CT information provides operators with new skills and techniques while applying attenuation correction values to the emission data. SPECT/CT also allows physicians to view and manipulate the data in 3 dimensions (30). Physicians have also reevaluated the reviewing and reporting of parathyroid images, to include the additional SPECT/CT datasets. Taking care that the appropriate look-up tables and α-blending techniques are used with SPECT/CT is essential to ensure optimal identification of diseases. Protocols for the processing and secondary capturing of processed data are also essential for archiving and optimal retrieval from central or local PACS environments.

The additional time required for SPECT/CT examinations should also be factored in when a new imaging service in introduced. Clinical departments with limited access to SPECT/CT systems are required to carefully organize the imaging work flow, ensuring that centralized patient waiting areas do not become controlled radiation environments.

Potential limitations of this study include patient conditions (e.g., tissue attenuation due to a high body mass index), injection technique (extravasation of radiopharmaceutical), and scanning technique (e.g., lack of patient communication, bad positioning, and inaccurate processing techniques). In addition, there were different protocols in place within the department, leading to administered activities ranging between 640 and 990 MBq. Finally, this was an initial evaluation of the clinical value of SPECT/CT, and we acknowledge that the sample population was relatively small (n = 9). A future study should include a larger population and a higher number of male patients. However, published research indicates that the incidence of parathyroid adenoma is higher in women than men and also increases with age (30,32).

CONCLUSION

This initial study demonstrated the clinical value of SPECT/CT in the management of parathyroid patients. Using SPECT/CT requires additional imaging time and, therefore, appropriate planning and organization. Consideration is also required for the level of CT used during the SPECT/CT data acquisition. Our SPECT/CT system consists of a 2-slice CT unit and allows for dose modulation. The CT data are used only for attenuation correction and localization, not for diagnosis. However, we realize that other clinical departments may use CT data for diagnostic purposes.

Using SPECT/CT has improved the overall accuracy rates of parathyroid examination in our clinical department, and undertaking this initial study has provided an opportunity to evaluate our current services for parathyroid referrals. Streamlining the procedural and processing aspects of this particular examination has also enabled the department workforce to offer greater flexibility and gain a better understanding of the optimal acquisition and processing parameters.

Acknowledgments

No potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Jul. 27, 2011.

REFERENCES

  1. 1.↵
    1. Mariani G,
    2. Gulec SA,
    3. Rubello D
    . Preoperative localization and radioguided parathyroid surgery. J Nucl Med. 2003;44:1443–1458.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Rubello D,
    2. Pelizzo MR,
    3. Boni G
    . Radioguided surgery of primary hyperparathyroidism using the low 99mTc-sestamibi dose protocol: multi-institutional experience from the Italian Study Group on Radioguided Surgery and ImmunoScintigraphy (GISCRIS). J Nucl Med. 2005;46:220–226.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Rubello D,
    2. Gross MD,
    3. Mariani G,
    4. Al-Nahhal A
    . Scintigraphic techniques in hyper-parathyroidism: from pre-operative localization to intra-operative imaging. Eur J Nucl Med Mol Imaging. 2007;34:926–933.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Billotey C,
    2. Sarfati E,
    3. Aurengo A
    . Advantages of SPECT in technetium-99m-sestamibi parathyroid scintigraphy. J Nucl Med. 1996;37:1773–1778.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Pattou F,
    2. Huglo D,
    3. Proye C
    . Radionuclide scanning in parathyroid disease. Br J Surg. 1998;85:1605–1616.
    OpenUrlCrossRefPubMed
  6. 6.
    1. Francis IS,
    2. Loney E,
    3. Buscombe JR,
    4. Thakrar DS,
    5. Berger L,
    6. Hilson AJW
    . 99Tcm-MIBI dual-phase SPET imaging: concordance with ultrasound. Nucl Med Commun. 1999;20:487–488.
    OpenUrl
  7. 7.↵
    1. Loney EL,
    2. Buscombe JR,
    3. Hilson AJW,
    4. Davenport A,
    5. Francis IS
    . Preoperative imaging of parathyroid glands. Lancet. 1999;354:1819–1820.
    OpenUrlPubMed
  8. 8.↵
    1. Moka D,
    2. Voth E,
    3. Dietlien M,
    4. Larean-Avellanda A,
    5. Schicha H
    . Technetium 99m-MIBI-SPECT: a highly sensitive diagnostic tool for localization of parathyroid adenomas. Surgery. 2000;128:29–35.
    OpenUrlCrossRefPubMed
  9. 9.
    1. O'Doherty MJ,
    2. Kettle AG
    . Parathyroid imaging: preoperative localization. Nucl Med Commun. 2003;24:125–131.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Spanu A,
    2. Falchi A,
    3. Manca A
    . The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism. J Nucl Med. 2004;45:40–48.
    OpenUrlAbstract/FREE Full Text
  11. 11.
    1. Rubello D,
    2. Massarro A,
    3. Cittadin S
    . Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery. Eur J Nucl Med Mol Imaging. 2006;33:1091–1094.
    OpenUrlCrossRefPubMed
  12. 12.
    1. Gayed IW,
    2. Kim EE,
    3. Broussard WF
    . The value of 99mTc-sestamibi SPECT/CT over conventional SPECT in the evaluation of parathyroid adenomas or hyperplasia. J Nucl Med. 2005;46:248–252.
    OpenUrlAbstract/FREE Full Text
  13. 13.
    1. Krausz Y,
    2. Bettman L,
    3. Guranlki L
    . Technetium-99m-MIBI SPECT/CT in primary hyperparathyroidism. World J Surg. 2006;30:76–83.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Serra A,
    2. Bolasco P,
    3. Satta L
    . Role of SPECT/CT in the preoperative assessment of hyperparathyroid patients. Radiol Med. 2006;111:999–1008.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Merrick M
    . Essentials of Nuclear Medicine. 2nd ed. London, U.K.: Springer Publications; 1998:112–146.
  16. 16.↵
    1. Perkins AC
    . Nuclear Medicine: Science and Safety. 3rd ed. London, U.K.: John Libbey and Company Ltd.; 1996: 94–145.
  17. 17.↵
    1. Ell PJ,
    2. Gambhir SS
    . Nuclear Medicine in Clinical Diagnosis and Treatment. 3rd ed. London, U.K.: Churchill Livingstone; 2004.
  18. 18.↵
    1. Saha GB
    . Fundamentals of Nuclear Pharmacy. 4th ed. New York, NY: Springer; 1997.
  19. 19.
    1. Powsner RP,
    2. Powsner ER
    . Essential Nuclear Medicine Imaging Physics. 4th ed. New York, NY: Blackwell Publishing; 2006:136–151.
  20. 20.↵
    1. Thrall J,
    2. Ziessman H
    . Medicina Nuclear. 2nd ed. Rio de Janeiro: Guanabara Koogan S.A.; 2003:28–31.
  21. 21.
    1. Grenier PR
    . Performance of scintillation cameras [abstract]. J Nucl Med. 1998;17(suppl):665P.
    OpenUrl
  22. 22.↵
    1. Júnior FAM,
    2. Guiberteau MJ
    . Essentials of Nuclear Medicine Imaging. 5th ed. London, U.K.: Saunders Elsevier; 2006:85–181.
  23. 23.
    1. Cherry RS,
    2. Sorenson JA,
    3. Phelps ME
    . Physics in Nuclear Medicine. 3rd ed. New York, NY: Saunders; 2003:195–197.
  24. 24.
    1. Pretorius PH,
    2. Vanrensburg AJ,
    3. Witter MG,
    4. Serfontein DE,
    5. Herbst CP
    . The channel ratio method of scatter correction for radionuclide image quantitation. J Nucl Med. 1993;34:330–335.
    OpenUrlAbstract/FREE Full Text
  25. 25.
    1. Hobbie RK
    . Intermediate Physics for Medicine and Biology. 4th ed. New York, NY: Struders; 1997:145–158.
  26. 26.
    Society of Nuclear Medicine procedure guideline for parathyroid scintigraphy. SNM Web site. Available at: http://interactive.snm.org/docs/Parathyroid_v3.0.pdf. Accessed May 19, 2011.
  27. 27.↵
    1. Murray IPC,
    2. Ell PJ
    . Nuclear Medicine in Clinical Diagnosis and Treatment. 2nd ed. London, U.K.: Churchill Livingstone; 1998:45–118.
  28. 28.↵
    1. Cherry RS,
    2. Sorenson JA,
    3. Phelps ME
    . Physics in Nuclear Medicine. 3rd ed. New York, NY: Saunders; 2005:170–187.
  29. 29.↵
    1. Tublin ME,
    2. Pryma D,
    3. Yim J,
    4. Ogilvie J,
    5. Mountz J,
    6. Bencherif B
    . Localization of parathyroid adenomas by sonography and technetium tc99m sestamibi single-photon emission computed tomography before minimally invasive parathyroidectomy: are both studies really needed? J Ultrasound Med. 2009;28:183–190.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Eslamy HK,
    2. Ziessman H
    . Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT. Radiographics. 2008;28:1461–1476.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Larsson W,
    2. Aspelin P,
    3. Bergquist M,
    4. et al
    . The effects of PACS on radiographer's work practice. Radiography. 2007;13:235–240.
    OpenUrlCrossRef
  32. 32.↵
    1. Bäcklund M,
    2. Grander D,
    3. Brandt L,
    4. Hall P,
    5. Ekbom A
    . Parathyroid adenoma and primary CNS tumors. Int J Cancer. 2005;113:866–869.
    OpenUrlCrossRefPubMed
  • Received for publication November 19, 2010.
  • Accepted for publication April 15, 2011.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 39 (3)
Journal of Nuclear Medicine Technology
Vol. 39, Issue 3
September 1, 2011
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Parathyroid Imaging and Localization Using SPECT/CT: Initial Results
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Parathyroid Imaging and Localization Using SPECT/CT: Initial Results
Ana Vaz, Marc Griffiths
Journal of Nuclear Medicine Technology Sep 2011, 39 (3) 195-200; DOI: 10.2967/jnmt.110.085522

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Parathyroid Imaging and Localization Using SPECT/CT: Initial Results
Ana Vaz, Marc Griffiths
Journal of Nuclear Medicine Technology Sep 2011, 39 (3) 195-200; DOI: 10.2967/jnmt.110.085522
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma
  • Solitary Parathyroid Adenoma Localization in Technetium Tc99m Sestamibi SPECT and Multiphase Multidetector 4D CT
  • Google Scholar

More in this TOC Section

  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Software Discrepancies in Radionuclide-Derived Left Ventricular Ejection Fraction
  • Monte Carlo Simulation of Characteristics of Discovery NM/CT 670 Pro SPECT System for Routinely Used Diagnostic and Therapeutic Radionuclides
Show more Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire