Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherIMAGING

Decreased Perfusion in the Lateral Wall of the Left Ventricle in PET/CT Studies with 13N-Ammonia: Evaluation in Healthy Adults

William C. Klingensmith, Carolyn Noonan, Jack H. Goldberg, Dedra Buchwald, John T. Kimball and Spero M. Manson
Journal of Nuclear Medicine Technology December 2009, 37 (4) 215-219; DOI: https://doi.org/10.2967/jnmt.109.062059
William C. Klingensmith III
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Carolyn Noonan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jack H. Goldberg
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dedra Buchwald
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John T. Kimball
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Spero M. Manson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

This study evaluated the causes of the frequently observed decreased myocardial perfusion in the lateral wall of the left ventricle in PET/CT studies with 13N-ammonia in healthy adults. Methods: Thirty-two adults who were undergoing PET/CT of the heart with 13N-ammonia as part of a study of the effects of posttraumatic stress disorder in American Indians were included. Participants who had evidence of heart disease by a physician-administered questionnaire or by pharmacologic stress during the myocardial perfusion study were excluded. The ratio of counts in the lateral wall relative to the septum at stress and rest were compared with the degree of misalignment between the PET and CT images at the left border of the heart and at the right hemidiaphragm. Results: No participant had evidence of heart disease. For the left heart border, 41% of participants showed misalignment at rest and 62% showed misalignment at stress. For the right hemidiaphragm, 28% showed misalignment at rest and 53% showed misalignment at stress. Among all participants, the decrease in lateral wall counts relative to the septum correlated with the degree of misalignment of the PET and CT images at the left heart border at rest using both average (P = 0.01) and maximum (P < 0.01) counts per pixel and at stress using maximum counts per pixel (P = 0.02) but not average counts per pixel (P = 0.14). There was also a correlation between the degree of misalignment of the PET and CT images at the left heart border and at the right hemidiaphragm at stress (P = 0.01) but not at rest (P = 0.09). The decreased counts in the lateral wall relative to the septum and the misalignment of the PET and CT images at the left heart border and at the right hemidiaphragm were all greater at stress than at rest (all P < 0.05). In those participants who had no misalignment of the PET and CT images at the left heart border, there was still a residual decrease in relative counts in the lateral wall at both stress and rest, using both average and maximum counts (all P < 0.05). Conclusion: Relative decreased counts in the lateral wall of the heart in PET/CT studies with 13N-ammonia are commonly seen in healthy adults. The decreased counts in the lateral wall appear to be caused by an attenuation artifact from misalignment at the left border of the heart between the PET and CT images, possibly related to differences in respiratory motion during acquisition of the PET and CT images. In addition, there was a small, but significant, decrease in relative counts in the lateral wall even in participants without misalignment at the left heart border or at the right hemidiaphragm.

  • myocardial perfusion imaging
  • PET/CT
  • 13N-ammonia
  • lateral wall artifacts
  • healthy adults

The development of combined PET/CT scanners has changed the method of generating density maps for attenuation correction of PET images. The previous method of acquiring a density map with an external rotating radioactive source had the disadvantages of requiring considerable time and being of low spatial resolution. On the other hand, the method had the advantage that the blurring effect of respiratory and cardiac motion was the same for the density map as it was for the PET images. The routine CT-acquired density map of the heart is acquired in a much shorter time and results in less blurring. Because the heart moves within the chest with respiration and there is a large difference in density between the heart and adjacent lung, attenuation correction artifacts in the lateral wall of the left ventricle have become common with PET/CT (1–6).

Even with conventional density maps generated with radioactive sources, there are reports of defects in the lateral wall of PET images of myocardial perfusion with 13N-ammonia (7,8). The cause of this finding has never been fully explained, leaving the possibility that the lateral wall defect is a normal finding in PET of the heart with 13N-ammonia (4). In addition, many studies of the lateral wall defect have used patients with known or likely coronary artery disease, making it difficult to separate artifact from disease with certainty (1,3,8).

The purpose of this study was to evaluate the lateral wall defect in PET/CT myocardial perfusion studies with 13N-ammonia in relation to respiratory motion and other factors in a relatively large number of adults without evidence of coronary artery disease.

MATERIALS AND METHODS

Participants and Setting

The research protocol was approved by the Institutional Review Board of the sponsoring institutions. The participants were part of the “Wounded Spirits, Ailing Hearts” study of the effects of posttraumatic stress disorder in American Indians. As part of an extensive evaluation, the participants underwent a physician-administered assessment that included asking about congenital heart disease, angina, coronary artery bypass surgery, percutaneous coronary angioplasty, and hospitalization for coronary heart disease. A positive answer to any question disqualified a participant from inclusion in this study. In addition, the blood pressure, heart rate, symptoms, and electrocardiograph during pharmacologic stress for PET/CT with 13N-ammonia were reviewed for any findings of coronary artery disease. Any indication of coronary artery disease disqualified the participant.

PET/CT Myocardial Perfusion Imaging

After a 4-h fast and placement of an intravenous line, the participant was placed in an inline PET/CT scanner with a 4-slice spiral CT component (DLS PET/CT; GE Healthcare). CT images of the lower chest were obtained in approximately 17 s during quiet breathing followed by the injection of 740 MBq (20 mCi) of 13N-ammonia intravenously. Four and a half minutes later, a 15-min electrocardiograph-gated set of static tomograms was obtained for evaluation of relative myocardial perfusion. The participant was allowed to get up at the end of the rest acquisition. At 45 min, the participant was again placed in the PET/CT scanner and a second CT scan of the lower chest was obtained. The participant was then stressed pharmacologically with a 45- to 60-mg infusion of dipyridamole intravenously over 4 min. Two minutes after the end of the infusion, 740 MBq (20 mCi) of 13N-ammonia were injected. Four and a half minutes later, a 15-min electrocardiograph-gated set of stress tomograms was obtained.

Image Analysis

The images were analyzed on a Xeleris workstation (GE Healthcare). In the mid portion of the transaxial images of the left ventricle, a vertically oriented rectangular region of interest was manually placed over the lateral wall and the average and maximum counts per pixel were recorded. The region of interest was then translated horizontally to overlie the septum, and again the average and maximum counts per pixel were recorded.

Then, using the original PET, CT, and fused images obtained transaxial to the body, the maximum extent to which the left ventricle in the PET image extended into the lung in the corresponding CT image was measured. In addition, the number of slices between the top of the right hemidiaphragm in the PET images and CT images was recorded as an indication of misalignment in the cephalocaudad direction.

Statistical Analysis

We assessed the correlation among the ratio of lateral wall counts relative to septal counts, the amount of misalignment at the left heart border, and the amount of misalignment at the top of the right hemidiaphragm using the Pearson correlation coefficient. Descriptive statistics for continuous variables included mean, SD, and range; percentages were computed for categoric variables.

Correlations were computed among counts in the lateral wall of the heart relative to the septum, degree of misalignment measured at the lateral heart border, and degree of misalignment at the top of the right hemidiaphragm while participants were at rest and under pharmacologic stress during imaging. A negative correlation indicates that as misalignment increases, the counts in the lateral wall relative to the septum decrease. For completeness, we present results for both average and maximum counts despite a strong correlation between the measures (r = 0.69 at rest, r = 0.74 at stress).

Paired t tests were used to compare the ratio of lateral wall counts relative to septal counts at rest and at stress. We also used paired t tests to compare the amount of misalignment at rest and at stress. In participants without misalignment at the left heart border, we used 1-sample t tests to examine if the ratio of lateral wall counts relative to septal counts differed from 1.0. A significant result indicates decreased counts in the lateral wall relative to the septum.

Because measures for the amount of misalignment did not follow a normal distribution, we also computed nonparametric equivalents to Pearson correlation (Spearman rank) and the paired t test (Wilcoxon signed ranks). For consistency, we present results from the parametric tests because statistical inference did not differ between the parametric and nonparametric tests.

Analyses were completed using Stata/SE 9.2 (StataCorp LP) for Windows (Microsoft). All statistical comparisons were 2-sided, and we used a P value of 0.05 as the threshold for significance.

RESULTS

Participants

All 32 participants had no history or current evidence of heart disease and were included in analyses. Most of the participants were female (81%), and the average age was 44 ± 9 y (range, 28–61 y).

Data Analysis

The amount of misalignment at the left heart border ranged from 0.0 to 11.3 mm at rest and 0.0 to 18.0 mm at stress. For the left heart border, 41% of participants at rest and 62% of participants at stress had misalignment (>0 mm). The amount of misalignment at the top of the right hemidiaphragm ranged from 0 to 2 slices at rest and 0 to 4 slices at stress. For the top of the right hemidiaphragm, 28% of participants at rest and 53% of participants at stress had misalignment (>0 slices).

Correlations among the ratio of lateral wall counts relative to septal counts, misalignment at the left heart border, and misalignment at the top of the right hemidiaphragm are shown in Table 1. At rest, we found significant negative correlations between lateral wall counts relative to the septum and misalignment at the left heart border for both average (r = −0.45) and maximum (r = −0.52) counts. The same association at stress was significant for maximum (r = −0.43), but not average (r = −0.26), counts. The correlation at rest between the amount of misalignment at the left heart border and the amount of misalignment at the top of the right hemidiaphragm was positive (r = 0.31) but not significant (P = 0.09). However, the same correlation at stress was significant (r = 0.45, P = 0.01).

View this table:
  • View inline
  • View popup
TABLE 1

Correlations Among Relative Lateral Wall Counts and Misalignments at Left Heart Border and Top of Right Hemidiaphragm

Correlations between the lateral wall counts relative to the septum and the amount of misalignment at the top of the right hemidiaphragm were smaller than analogous associations at the left heart border and not significant.

Differences between rest and stress in the relative counts in the lateral wall, compared with the septum, the degree of misalignment at the left heart border, and the degree of misalignment at the top of the right hemidiaphragm, are presented in Table 2. Participants had a significantly lower lateral wall count relative to the septum at stress than at rest for both average (P < 0.01) and maximum (P = 0.02) counts, greater misalignment at the left heart border at stress than at rest (P = 0.02), and greater misalignment at the top of the right hemidiaphragm at stress than at rest (P < 0.01).

View this table:
  • View inline
  • View popup
TABLE 2

Comparison of Relative Lateral Wall Counts and Misalignments at Stress and at Rest

Finally, we examined the counts in the lateral wall relative to the septum in participants with no misalignment at the left heart border (Table 3). Among the 19 participants with no misalignment at rest, the average and maximum counts were lower in the lateral wall than in the septum (P = 0.03 and P = 0.01, respectively). Among the 12 participants with no misalignment at stress, both the average and the maximum counts were lower in the lateral wall than in the septum (P < 0.01 for both).

View this table:
  • View inline
  • View popup
TABLE 3

Counts in Lateral Wall Relative to Septum in Patients Without Left Heart Border Misalignment at Stress and at Rest

DISCUSSION

This study, based on 32 adults without evidence of heart disease, demonstrates that the relative decreased counts in the lateral wall of the left ventricle of the heart seen in PET/CT studies with 13N-ammonia correlates with misalignment of the PET and CT images at the left heart border. This misalignment appears to be related to differences in respiratory motion during acquisition of the PET and CT images. Furthermore, the decreased counts in the lateral wall relative to the septum, and misalignment of the left heart border and top of the right hemidiaphragm, were all worse at stress. Of note, in participants without evidence of misalignment at the left heart border, the counts in the lateral wall were less than in the septum and this disparity increased at stress.

Relatively decreased counts in the lateral wall in PET perfusion studies with 13N-ammonia were observed even before the development of combined PET/CT scanners (8). However, this phenomenon appears to be more common with PET/CT scanners (1–8). In our patients, 41% showed misalignment at the left heart border at rest and 62% showed misalignment at the left heart border at stress. In addition, 28% showed misalignment at the top of the right hemidiaphragm at rest, whereas 53% showed misalignment at the top of the right hemidiaphragm at stress. A significantly greater percentage of participants had misalignment at the top of the right hemidiaphragm at stress than at rest, most likely resulting from an increase in respiratory motion from the effects of pharmacologic stress.

The correlation between the relative decreased counts in the lateral wall of the left ventricle and the degree of misalignment between the PET and CT images at the lateral border of the heart, as well as the correlation between misalignment at the left heart border and at the top of the right hemidiaphragm, suggests that the decreased counts in the lateral wall of the left ventricle are secondary to an attenuation artifact that, in turn, may be secondary to respiratory motion.

Several maneuvers have been suggested to prevent or correct misalignment of the PET and CT images with respect to the heart, such as increasing the time of acquisition of the CT images over multiple respiratory cycles to create the same respiratory averaging present in the PET images (9–11). Others have suggested acquiring the CT images at end expiration, when the lateral border of the heart would be expected to extend to the left to the greatest extent (12). For stress images, some have tried respiratory gating or acquiring the CT image after the PET acquisition so that the effect of pharmacologic stress on breathing will have decreased (13–16). The most reliable approach, however, is probably the use of software to manually coregister the PET and CT images or to manually adjust all CT pixels that correspond to the heart in the PET images to the density of the heart in the CT images (2,8,17–19).

It has been suggested that the decreased perfusion in the lateral wall is a physiologic finding that is perhaps due to a local difference in the metabolism of ammonia (6). Others have not found a decrease in perfusion in the lateral wall after optimal attenuation correction (1). Our data indicate a small, but significant, decrease in perfusion in the lateral wall relative to the septum even in participants without any discernible misalignment of the PET and CT images at the lateral border of the heart. This finding may be physiologic or due to factors other than detectable misalignment.

A noteworthy limitation of this study was the lack of robust software options in the Xeleris workstation for creating regions of interest and measuring counts in any desired portion of the left ventricle. This limitation may account for some of the statistically insignificant findings between parameters that would be expected to be strongly associated, such as relatively decreased counts in the lateral wall versus misalignment of the top of the right hemidiaphragm.

PET/CT has substantial advantages over conventional nuclear medicine imaging with γ-cameras. It has higher and more uniform spatial resolution, better CT correlation for anatomic localization, and, because of the greater variety of potential radiopharmaceuticals, the ability to image metabolism as well as physiology. However, despite the desirability of moving nuclear medicine myocardial imaging to PET/CT to take advantage of its superior technology, the frequent lateral wall artifact with current equipment and protocols is a limiting factor. We hope that manufacturers will develop software applications that will allow easy correction of misalignment between PET and CT images.

CONCLUSION

This study provided evidence that decreased counts in the lateral wall of the left ventricle in PET/CT myocardial studies with 13N-ammonia occur frequently and are related to an attenuation artifact caused by misalignment of the PET and CT images at the left heart border. The misalignment at the left heart border seems to be related to respiratory motion and is more marked at stress. Finally, in those participants without evidence of misalignment at the left heart border, we observed a residual small decrease in lateral wall counts, compared with the septum.

Acknowledgments

Financial support was provided by “Wounded Spirits, Ailing Hearts: Post-Traumatic Stress Disorder and Cardiovascular Disease in Indians,” a trial sponsored by the National Heart, Lung, and Blood Institute (RO1 HL073824).

Footnotes

  • COPYRIGHT © 2009 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Koepfli P, Hany TF, Wyss CA, et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J Nucl Med. 2004;45:537–542.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    Schwaiger M, Ziegler S, Nekolla SG. PET/CT: challenge for nuclear cardiology. J Nucl Med. 2005;46:1664–1678.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    Martinez-Moller A, Souvatzoglou M, Navab N, et al. Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions. J Nucl Med. 2007;48:188–193.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    Cook RAH, Carnes G, Lee TY, et al. Respiration-averaged CT for attenuation correction in canine PET/CT. J Nucl Med. 2007;48:811–818.
    OpenUrlAbstract/FREE Full Text
  5. 5.
    Alessio AM, Kohlmyer S, Branch K, et al. Cine CT for attenuation correction in cardiac PET/CT. J Nucl Med. 2007;48:794–801.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    Di Carli MF, Dorbala S, Meserve J, et al. Clinical myocardial perfusion PET/CT. J Nucl Med. 2007;48:783–793.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    de Jong RM, Blanksma PK, Willemsen ATM, et al. Posterolateral defect of the normal human heart investigated with nitrogen-13-ammonia and dynamic PET. J Nucl Med. 1995;36:581–585.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    Loghin C, Sdringola S, Gould KL. Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions. J Nucl Med. 2004;45:1029–1039.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    Pan T, Mawlawi O, Nehmeh SA, et al. Attenuation correction of PET images with respiration-averaged CT images in PET/CT. J Nucl Med. 2005;46:1481–1487.
    OpenUrlAbstract/FREE Full Text
  10. 10.
    Brunken RC, DiFilippo FP, Bybel B, et al. Clinical evaluation of cardiac PET attenuation correction using “fast” and “slow” CT images [abstract]. J Nucl Med. 2004;45(suppl):120P.
    OpenUrl
  11. 11.↵
    Nye JA, Votaw JR, Esteves F. Attenuation correction of cardiac PET/CT with gated, fast, and slow acquisition of the transmission map [abstract]. J Nucl Med. 2006;47(suppl):132P.
    OpenUrl
  12. 12.↵
    Bacharach SL. PET/CT attenuation correction: breathing lessons. J Nucl Med. 2007;48:677–679.
    OpenUrlFREE Full Text
  13. 13.↵
    Dorbala S, Limaye A, Sampson U, et al. Optimal timing of transmission MAP for rubidium 82 stress positron emission tomography (PET-CT) myocardial perfusion imaging [abstract]. J Nucl Med. 2005;46(suppl):267P.
    OpenUrl
  14. 14.
    Youssef IM, Colon D, Rafique A, et al. The benefit of two CT transmission scans for rubidium-82 cardiac PET myocardial perfusion imaging [abstract]. J Nucl Med. 2005;46(suppl):115P.
    OpenUrl
  15. 15.
    Livieratos L, Rajappan K, Stegger L, et al. Respiratory gating of cardiac PET data in list-mode acquisition. Eur J Nucl Med Mol Imaging. 2006;33:584–588.
    OpenUrlCrossRefPubMed
  16. 16.↵
    Lautamäki R, Brown TL, Merrill J, Bengel FM. CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution. Eur J Nucl Med Mol Imaging. 2008;35:305–310.
    OpenUrlCrossRefPubMed
  17. 17.↵
    Gould KL, Pan T, Loghin C, et al. Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections. J Nucl Med. 2007;48:1112–1121.
    OpenUrlAbstract/FREE Full Text
  18. 18.
    Wilson JW, Wong TZ, Borges-Neto S, et al. An algorithm for correction of PET/CT mismatch induced cardiac attenuation correction artifacts [abstract]. J Nucl Med. 2005;46(suppl):55P.
    OpenUrl
  19. 19.↵
    Nehmeh SA, Yusuf EE. Respiratory motion in positron emission tomography/computed tomography: a review. Semin Nucl Med. 2008;38:167–176.
    OpenUrlCrossRefPubMed
  • Received for publication January 10, 2009.
  • Accepted for publication October 16, 2009.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 37 (4)
Journal of Nuclear Medicine Technology
Vol. 37, Issue 4
December 2009
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Decreased Perfusion in the Lateral Wall of the Left Ventricle in PET/CT Studies with 13N-Ammonia: Evaluation in Healthy Adults
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Decreased Perfusion in the Lateral Wall of the Left Ventricle in PET/CT Studies with 13N-Ammonia: Evaluation in Healthy Adults
William C. Klingensmith, Carolyn Noonan, Jack H. Goldberg, Dedra Buchwald, John T. Kimball, Spero M. Manson
Journal of Nuclear Medicine Technology Dec 2009, 37 (4) 215-219; DOI: 10.2967/jnmt.109.062059

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Decreased Perfusion in the Lateral Wall of the Left Ventricle in PET/CT Studies with 13N-Ammonia: Evaluation in Healthy Adults
William C. Klingensmith, Carolyn Noonan, Jack H. Goldberg, Dedra Buchwald, John T. Kimball, Spero M. Manson
Journal of Nuclear Medicine Technology Dec 2009, 37 (4) 215-219; DOI: 10.2967/jnmt.109.062059
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • The Effect of Misregistration Between CT-Attenuation and PET-Emission Images in 13N-Ammonia Myocardial PET/CT
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire