Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Efficiency of Radiolabeling Eggs Before and After Microwave Cooking for Gastric Emptying Scintigraphy Studies

Jena-Lee McKee, Mary Beth Farrell, Kathy Hunt, Vivian Loveless and Charity Brannen
Journal of Nuclear Medicine Technology June 2019, 47 (2) 144-148; DOI: https://doi.org/10.2967/jnmt.118.225177
Jena-Lee McKee
1West Tennessee Healthcare, Dyersburg Hospital, Dyersburg, Tennessee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mary Beth Farrell
2Intersocietal Accreditation Commission, Ellicott City, Maryland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kathy Hunt
3Baptist College of Health Sciences, Memphis, Tennessee; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vivian Loveless
4UTHSC College of Pharmacy, Memphis, Tennessee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Charity Brannen
3Baptist College of Health Sciences, Memphis, Tennessee; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The accuracy and reproducibility of nuclear medicine gastric emptying scintigraphy (GES) require strict adherence to the Society of Nuclear Medicine and Molecular Imaging standardized protocol, which contains precise instructions for meal ingredients and preparation. Previous research demonstrated that many laboratories were using whole eggs in the test meal as opposed to the guideline-recommended liquid egg whites and that some laboratories were attempting to radiolabel the egg by adding the radiotracer after cooking. This study aimed to document the labeling efficiency of 99mTc-sulfur colloid (SC) added to whole eggs before and after microwave cooking. Methods: Whole eggs were mixed with 99mTc-SC before and after microwave cooking. The radiolabeling stability of the eggs was tested after 2 and 4 h of incubation in gastric fluid simulated using just hydrochloric acid (HCl) and using HCl with pepsin. Results: The experiment showed that no matter what the testing condition, radiolabeling by adding 99mTc-SC to whole eggs before cooking resulted in a significantly higher labeling efficiency than radiolabeling by squirting the 99mTc-SC on eggs after cooking. This finding persisted over time, with the precooking method still showing significantly higher radiolabeling at 2 and 4 h after the egg was placed in the incubation medium for both gastric fluid mediums. For simulated gastric fluid with pepsin at 2 h, the labeling was significantly higher, at 73.3%, when the radiotracer was added before cooking than the 43.3% when added after cooking (P < 0.001). The results of this study further showed that when egg labeling efficiency was tested in HCl without pepsin, the labeling was less stable than when tested in HCl with pepsin. In the HCl-only medium, the labeling efficiency decreased significantly between 2 and 4 h for both radiolabeling methods. Conclusion: The results of this study demonstrated that the addition of 99mTc-SC to whole eggs after cooking resulted in considerably inferior binding of the radiotracer to the eggs and that binding deteriorated significantly over time. The study further demonstrated that the results of radiolabeling efficiency varied depending on whether HCl or HCl with pepsin was used to simulate gastric fluid. Radiolabeling stability decreased over time when HCl without pepsin was used. The findings emphasize the criticality of adhering to the standardized meal and preparation, as alternate cooking methods have different radiolabeling efficiencies.

  • gastric emptying scintigraphy
  • radiolabeling stability
  • guidelines
  • meal preparation

Gastric emptying scintigraphy (GES) is frequently performed in nuclear medicine to evaluate gastric motility (1). GES is accomplished by radiolabeling the solid or liquid component of a meal and then measuring the radioactivity in the stomach over time. It has become the gold standard for measuring the rate of gastric emptying because of the noninvasive, physiologic, and quantifiable properties of the test.

However, numerous factors such as patient status, test meal composition and preparation, image acquisition parameters, and the method of data analysis can affect the accuracy and reproducibility of the results. To reduce variation in test performance and results, a standardized GES protocol was needed. In 2009, the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published Procedure Guideline for Adult Solid-Meal Gastric Emptying Study 3.0 (2). The standardized protocol must be strictly followed to deliver reliable results.

The SNMMI standardized GES protocol contains precise instructions for patient preparation, including medication withholding, blood glucose level, and fasting state; meal ingredients and preparation; radiopharmaceutical dose; image views and frequency; and image processing using the geometric mean, decay correction, and percentage retention (2).

Of specific interest for this study, the requisite GES meal includes 118 mL (4 oz) of liquid egg whites such as Eggbeaters (ConAgra Foods, Inc.), 2 slices of toasted white bread, 30 g of jam or jelly, and 120 mL of water (2). To prepare the meal, 18.5–37 MBq (0.5–1 mCi) of 99mTc-sulfur colloid (SC) is added to the liquid egg whites, which are then beaten well and cooked in a microwave oven or nonstick skillet. The egg whites with the 99mTc-SC are stirred once or twice during cooking and cooked until firm. The jelly is spread on the bread after it is toasted. The meal items can be eaten separately or as a sandwich along with consumption of the water.

Despite the publication of the standardized GES protocol in 2009, a study by Farrell et al. in 2017 found considerable protocol noncompliance (3). Specifically, their research showed that 69.3% of laboratory protocols do not adhere to the standardized meal. Many laboratories (48.1%) used whole eggs instead of the obligatory liquid egg whites. Numerous laboratories injected the radiopharmaceutical directly into the egg yolk. Anecdotally, Farrell et al. noted that several laboratories asked patients to bring scrambled eggs with them to their appointment, and the technologist then squirted the 99mTc-SC on the previously cooked eggs.

As these findings were unquestionably contrary to the advocated SNMMI GES standardized protocol, this study aimed to document the binding rate of 99mTc-SC added to whole eggs before or after microwave cooking.

MATERIALS AND METHODS

Radiotracer Labeling Method

Two radiotracer labeling methods were used during the study to prepare the eggs for the GES meal. The same cooking technique was used for both radiolabeling methods. In the first method (precooking labeling), 2.6 MBq (71 μCi) of 99mTc-SC were added to the whole egg and mixed well before microwave cooking. In the second method (postcooking labeling), 3.0 MBq (84–89 μCi) of 99mTc-SC were squirted onto the previously cooked eggs.

Cooking Method

One egg (Eggland’s Best, LLC) was transferred from its shell to a 118-mL (4-oz) polystyrene foam cup and beaten for 30 s until the yolk and egg white were well blended. The beaten egg (with or without 99mTc-SC as noted above) was cooked by microwave in the same cup as that used for mixing. The mixture was cooked to a firm consistency on high power for 45 s, with stirring at 15-s intervals.

Simulated Gastric Fluid

The stomach has 2 digestive processes that were replicated in this study: chemical and mechanical (4). During the chemical process, gastric fluid is produced in the stomach and the pH is between 1.5 and 3.0 (5). Because human gastric fluid was not available for this research, simulated gastric fluid was used to mimic human digestion of proteins. The base of the simulated gastric fluid used in this experiment consisted of 3.5 mL of hydrochloric acid (HCl) (0.0847 M) combined with 3.06 g of sodium chloride (NaCl) (0.1044 M) in 500 mL of distilled water, resulting in a pH of 1.5 (6).

In the stomach, HCl converts pepsinogen, which is also produced in the stomach, to pepsin. Pepsin breaks down proteins to peptides. Several previous studies evaluating the stability of radiotracer binding to the solid-meal component were conducted using only HCl. However, evaluation in HCl without pepsin may lead to misleading results because the meal may be stable in HCl but not in HCl with pepsin (7). For this reason, the study was conducted both without and with 0.1 g of pepsin added to the test tubes.

Simulated Digestion

The cooked eggs were cooled to room temperature and chopped to mimic chewing (Fig. 1B). Egg samples (labeled “pre–microwave cooking” and “post–microwave cooking”) weighing 0.5 g (Fig. 1A) were placed in 47 test tubes (6 per condition; however, 1 tube was damaged during the experiment and removed) containing 1.25 mL of HCl (Fig. 2). Pepsin was combined with HCL for half the test tubes. The tubes were then paraffin-capped and placed in a water bath at 37°C with stirrers at 125 rpm for 2 and 4 h to mimic mechanical and chemical digestion (Fig. 1C).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Photographs showing weighing method to ensure standardized 0.5-g radiolabeled egg sample size (A), egg samples before being added to simulated gastric fluid (B), and 37°C water bath and stirring at 125 rpm (C).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Egg labeling test conditions. Two methods were used to radiolabel whole eggs with 99mTc-SC. In method 1, 99mTc-SC was added to beaten eggs before microwave cooking. In method 2, 99mTc-SC was squirted on eggs after microwave cooking. Stability of radiolabel was tested for both methods at 2 and 4 h. Stability was also tested in gastric fluid simulated using just HCl and using HCL with pepsin.

Radiolabeling Stability Testing

To separate the sold egg material from the liquid, a filter was created using a 3-mL syringe barrel and sterile gauze. The gauze was cut and folded into 2.54 × 2.54 cm (1 × 1 in) sections and packed into the barrel of the syringe (Fig. 3A).The gauze filter was then wet with 0.5 mL of 1% bovine serum albumin in isotonic saline. The bovine serum albumin was used to prevent 99mTc-SC adhesion to the gauze (8). The bovine serum albumin rinse was followed by a 1-mL isotonic saline rinse.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A) To test stability of radiolabeled eggs, filter was created using gauze and 3-mL syringe. Gauze was wet with 0.5 mL of 1% bovine serum albumin to prevent adhesion of 99mTc-SC to syringe and gauze. (B and C) To separate solid material from liquid in test tubes, egg and digesting fluid were transferred to previously prepared syringes with gauze at 2 h (B) and 4 h (C) after start of test.

To separate the solid material from the liquid in the test tubes, the egg and fluid were transferred to the previously prepared syringes with gauze at 2 and 4 h after the start of the test (Figs. 3B and 3C). To ensure that all material was transferred from the test tube to the syringe, the test tube was rinsed once with 1 mL of isotonic saline, which was also filtered through the syringe.

The gauze with undigested egg material, the liquid filtered from the digestive solution, and the rinse were counted in a well counter (8). The counted activity was background- and decay-corrected.

Labeling efficiency (%) was determined as gauze + egg counts (disintegrations per minute)/total counts (disintegrations per minute) (gauze + egg + filtrate + rinse) × 100. Independent Student t tests were used to compare the labeling efficiency of the samples. Comparisons were made between labeling methods (precooking labeling vs. postcooking labeling), between incubation times (2 vs. 4 h), and between HCl with and without added pepsin.

RESULTS

Comparing the timing of the 99mTc-SC egg labeling—whether the tracer was added before or after microwave cooking—showed that no matter whether the sample was counted at 2 h or 4 h and with or without pepsin added to the digestive solution, the radiotracer binding to the eggs was always significantly higher when the radiotracer was added before the eggs were cooked. For example, in the plain HCl solution at 2 h, the labeling efficiency was 95.4% when the radiotracer was added before cooking and 42.3% when added after cooking (P < 0.001). Similarly, in the digestive fluid with pepsin at 2 h, the labeling was significantly higher, at 73.3%, when the radiotracer was added before cooking than the 43.3% when added after cooking (P < 0.001) (Tables 1⇓–3).

View this table:
  • View inline
  • View popup
TABLE 1

Percentage of 99mTc-SC Bound to Whole Eggs Before and After Cooking

View this table:
  • View inline
  • View popup
TABLE 2

Percentage of 99mTc-SC Bound to Whole Eggs at 2- and 4-Hour Incubations

View this table:
  • View inline
  • View popup
TABLE 3

Percentage of 99mTc-SC Bound to Whole Eggs Without and With Pepsin

Comparing the stability of the radiotracer labeling over time showed that for simulated digestive fluid with just HCl, when the radiotracer was added before cooking, the labeling efficiency of the eggs significantly decreased between 2 h (95.4%) and 4 h (78.0%) (P = 0.01). Similarly, when the radiotracer was added after cooking, the labeling efficiency also significantly decreased at 2 h (57.3%) and 4 h (39.5%) (P = 0.02). However, when the digestive fluid contained both HCl and pepsin, radiotracer labeling efficiency did not change significantly between 2 h and 4 h no matter whether the radiotracer was added before (73.3% vs. 73.1%, P = 0.94) or after cooking (43.3% vs. 35.0%, P = 0.10).

DISCUSSION

The accuracy and reproducibility of nuclear medicine GES require strict adherence to the SNMMI standardized protocol (1). A recent study by Farrell et al. found that a majority of nuclear laboratories performing GES are not in compliance with the standardized protocol (3). In particular, almost half the laboratories evaluated used whole eggs in the test meal as opposed to the requisite liquid egg whites. In addition, Farrell et al. noted that several laboratories attempted to label the eggs by adding the radiotracer after cooking. Both methods are contrary to the methods detailed in the SNMMI standardized protocol.

This study aimed to document the labeling efficiency of 99mTc-SC added to whole eggs before and after microwave cooking. The experiment showed that no matter what the test condition, radiolabeling efficiency was significantly higher when 99mTc-SC was added to eggs before cooking than when 99mTc-SC was squirted on eggs after cooking. This finding persisted over time, with the precooking method still showing significantly higher radiolabeling at 2 and 4 h after the egg was placed in the simulated gastric fluid.

The study finding that labeling efficiency was significantly higher when 99mTc-SC was added to eggs before cooking was not surprising. It is known that 99mTc-SC fixes to albumin (egg white protein), which denatures as it cooks, binding the 99mTc-SC. Adding 99mTc-SC to previously cooked eggs does not allow the 99mTc-SC to bind to the albumin and then be denatured (10). The radiolabeling range of 35.0%–56.3% in the postcooking method was expected. Thus, the postcooking method of radiolabeling, in which the 99mTc-SC is squirted on eggs after microwave cooking, is not optimal and should not be used.

The results of this study further showed that when egg labeling efficiency was tested in a simulated gastric fluid containing only HCl, the labeling was less stable and the labeling efficiency decreased significantly between 2 and 4 h. This finding occurred for both radiolabeling cooking methods. However, when the simulated digestive fluid more closely mimicked real human digestive fluid including pepsin, the labeling efficiency remained unchanged between 2 and 4 h. This finding indicates that use of a simulated gastric fluid with only HCl may be misleading in that the radiolabeled eggs may not be as stable in HCl as in HCl with pepsin (7).

The results of this study are similar to the findings obtained by Knight et al. in 2007 (8). At 2 h, Knight et al. found the labeling efficiency of whole eggs tested in HCl (precooking labeling) to be 96.9%, compared with our finding of 95.4%. In a similar experiment, Ertay et al. (9) documented a labeling efficiency of 95%. In human gastric fluid at 2 h (9), the labeling efficiency obtained by Ertay et al. was 73.1%. The labeling efficiency in this experiment using simulated gastric fluid was 73.3%.

Incongruently, Knight et al. had different results at 4 h in HCl testing fluid without pepsin (8). In their experiment, the labeling efficiency was not significantly different between 2 h and 4 h. The labeling efficiency was 96.9% at 2 h and 97.3% at 4 h. However, in our experiment, the labeling efficiency tested in HCl decreased significantly from 95.4% at 2 h to 78.0% at 4 h. Contrarily, in human gastric fluid, Knight et al. found that the labeling efficiency decreased significantly from 73.1% at 2 h to 42.5% at 4 h. However, our results found that the labeling efficiency remained unchanged, at 73.3% at 2 h and 73.1% at 4 h.

The reason for the incongruent findings at 4 h between our results and those of Knight et al. is difficult to suppose. However, a possible explanation may be that Knight et al. used actual human gastric fluid obtained from subjects undergoing elective endoscopy (8). Our experiment used HCl with pepsin added to simulate gastric fluid.

Differences in experimental technique related to egg beating and mixing or cooked egg firmness may also explain the difference in results at 4 h between our experiment and that of Knight et al. (8). Differences in binding stability could have been exacerbated by the use of whole eggs as opposed to the recommended egg whites. 99mTc-SC binds to the albumin or egg white protein and the egg white is denatured and bound during cooking (10). Knight et al. demonstrated the possible fluctuation while microwaving whole eggs, which, unlike the liquid egg whites, allowed the albumin to separate from the yolks during the cooking process. 99mTc-SC does not bind to egg yolks.

Strict adherence to the standard gastric emptying meal and preparation method is critical for accurate GES results. The 99mTc-SC must bind tightly to the egg, forming the solid component of the meal (11). The gastric emptying rate of solids and liquids is different. Liquids begin leaving the stomach immediately on ingestion, with an exponential rate of emptying. Solids enter the stomach and are broken down by mechanical contraction and gastric fluid. Solids empty more slowly after a lag phase and then at a fixed rate. If the 99mTc-SC is not tightly bound to the eggs (solid component) because of improper labeling, the study essentially becomes a liquid GES because part of the meal exits the stomach as a liquid. This creates the possibility of a false-negative GES.

This study was somewhat limited because whole eggs instead of the recommended liquid egg whites were used to test radiolabeling stability. However, considering the findings by Farrell et al. (3) that many laboratories use whole eggs and add the radiotracer after cooking, the results of this study using whole eggs and different cooking methods demonstrates unsatisfactory radiolabeling efficiency. This study is also limited in that the adequacy of mixing and cooking was not tested. However, Knight et al. (8) imaged the cooking methods of whole eggs versus liquid egg whites and noted nonhomogeneous albumin and yolk during microwave cooking. Bonta et al. evaluated the quality of meal preparation and egg mixing between technologists by imaging the radiolabeled eggs before patient ingestion (12).

CONCLUSION

The accuracy and reproducibility of nuclear medicine GES are dependent on strict compliance with the SNMMI standardized protocol. This study documented the radiolabeling stability of 99mTc-SC added to whole eggs before and after microwave cooking. The results showed that the addition of 99mTc-SC to whole eggs after cooking resulted in inferior binding of the radiotracer to the eggs, with the binding deteriorating significantly over time. The study further demonstrated that the results of radiolabeling efficiency vary depending on whether HCl or HCl with pepsin is used to simulate gastric fluid. Radiolabeling stability decreased over time when HCl without pepsin was used. The results emphasize the criticality of adherence to the standardized meal and preparation, as alternate cooking methods have varying radiolabeling efficiencies.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Acknowledgments

We had access to the laboratories and supplies of Baptist College Health Sciences, with Charity Brannen, PhD, Assistant Professor of Chemistry, and to those of UT Health Sciences, with Vivian S. Loveless, PharmD, BCNP, FAPhA, Associate Professor of Pharmaceutical Sciences. Robert Irwin, DPh, GE Nuclear Pharmacy, and Mohammed Moinuddin, MD, were also a part of our supporting staff for any questions or concerns that arose during this research project.

Footnotes

  • Published online Apr. 24, 2019.

REFERENCES

  1. 1.↵
    1. Abell TL,
    2. Camilleri M,
    3. Donohoe K,
    4. et al
    . Consensus recommendations for gastric emptying scintigraphy: a joint report of the American Neurogastroenterology and Motility Society and the Society of Nuclear Medicine. J Nucl Med Technol. 2008;36:44–54.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Donohoe KJ,
    2. Maurer AH,
    3. Ziessman HA,
    4. et al
    . Procedure guideline for adult solid-meal gastric-emptying study 3.0. J Nucl Med Technol. 2009;37:196–200.
    OpenUrlFREE Full Text
  3. 3.↵
    1. Farrell MB,
    2. Costello M,
    3. McKee JD,
    4. Gordon LL,
    5. Fig LM
    . Compliance with gastric-emptying scintigraphy guidelines: an analysis of the Intersocietal Accreditation Commission database. J Nucl Med Technol. 2017;45:6–13.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Christian PE,
    2. Waterstram-Rich KM
    1. Urbain JLC,
    2. Malmud LS
    . Gastrointestinal system. In: Christian PE, Waterstram-Rich KM, eds. Nuclear Medicine and PET/CT Technology and Techniques. 6th ed. St. Louis, MO: Mosby Elsevier; 2007:526–532.
  5. 5.↵
    1. Vertzoni M,
    2. Dressman J,
    3. Butler J,
    4. Hempenstall J,
    5. Reppas C
    . Simulation of fasting gastric conditions and its importance for the in vivo dissolution of lipophilic compounds. Eur J Pharm Biopharm. 2005;60:413–417.
    OpenUrlPubMed
  6. 6.↵
    1. Guzman ML,
    2. Marques M,
    3. Olivera M,
    4. Stippler E
    . Enzymatic activity in the presence of surfactants commonly used in dissolution media, part 1: pepsin. Results Pharma Sci. 2016;6:15–19.
  7. 7.↵
    1. Knight LC
    . Update on GI radiopharmaceuticals and dosimetry estimates. Semin Nucl Med. 2012;42:138–144.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Knight LC,
    2. Kantor S,
    3. Doma S,
    4. Parkman HP,
    5. Maurer AH
    . Egg labeling methods for gastric emptying scintigraphy are not equivalent in producing a stable solid meal. J Nucl Med. 2007;48:1897–1900.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Ertay T,
    2. Doğan AS,
    3. Ulker O,
    4. Durak H
    . In vitro evaluation of Tc-99m radiopharmaceuticals for gastric emptying studies. Mol Imaging Radionucl Ther. 2014;23:21–24.
    OpenUrl
  10. 10.↵
    1. Yoshinori M,
    2. Tatsushi N,
    3. Noriyuki H
    . Thermally induced changes in egg white proteins. J Agric Food Chem. 1990;38:2122–2125.
    OpenUrlCrossRef
  11. 11.↵
    1. Bolus N,
    2. Farrell MB,
    3. Zimmerman J
    1. Farrell MB
    . Gastric emptying scintigraphy. In: Bolus N, Farrell MB, Zimmerman J, eds. Abdominal imaging 2017: Quality Safety, & Dose Optimization. Reston, VA: Society of Nuclear Medicine and Molecular Imaging; 2017:23–39.
  12. 12.↵
    1. Bonta DV,
    2. Brandon DC,
    3. Hernandez J,
    4. Patel M,
    5. Grant S,
    6. Alazraki N
    . Clinical intervention for quality improvement of gastric-emptying studies. J Nucl Med Technol. 2014;42:274–277.
    OpenUrlAbstract/FREE Full Text
  • Received for publication January 2, 2019.
  • Accepted for publication March 18, 2019.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 47 (2)
Journal of Nuclear Medicine Technology
Vol. 47, Issue 2
June 1, 2019
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Efficiency of Radiolabeling Eggs Before and After Microwave Cooking for Gastric Emptying Scintigraphy Studies
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Efficiency of Radiolabeling Eggs Before and After Microwave Cooking for Gastric Emptying Scintigraphy Studies
Jena-Lee McKee, Mary Beth Farrell, Kathy Hunt, Vivian Loveless, Charity Brannen
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 144-148; DOI: 10.2967/jnmt.118.225177

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Efficiency of Radiolabeling Eggs Before and After Microwave Cooking for Gastric Emptying Scintigraphy Studies
Jena-Lee McKee, Mary Beth Farrell, Kathy Hunt, Vivian Loveless, Charity Brannen
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 144-148; DOI: 10.2967/jnmt.118.225177
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Gastric Emptying Solid-Meal Content and Misinformation on Social Media Platforms
  • An Evaluation of Gastric Emptying Scintigraphy Protocols in Health Care Institutions When Compared with the Society of Nuclear Medicine and Molecular Imaging Procedure Guidelines
  • The Efficacy of Radiolabeling the Albumin in Egg Whites with 99mTc-Sulfur Colloid
  • Readers Help to Shape JNMT Content
  • Google Scholar

More in this TOC Section

  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
  • Software Discrepancies in Radionuclide-Derived Left Ventricular Ejection Fraction
Show more Imaging

Similar Articles

Keywords

  • gastric emptying scintigraphy
  • radiolabeling stability
  • guidelines
  • meal preparation
SNMMI

© 2025 SNMMI

Powered by HighWire