Visual Abstract
Abstract
Dynamic antral contraction scintigraphy (DACS) has been used to evaluate for gastric dysmotility by measuring antral contraction frequency and ejection fraction (EF). Fourier phase image analysis has the potential to assess gastric antral contractions for dyssynchrony as has been used for analyzing nuclear cardiology ventriculography (multigated acquisition studies) for cardiac dyssynchrony. The aims of this study were to determine whether Fourier phase analysis helps to characterize antral motility physiology, whether Fourier phase analysis correlates with conventional gastric emptying scintigraphy (GES), and which DACS parameters may aid in diagnosing gastric dysmotility, particularly delayed gastric emptying (GE). Methods: DACS and GES of healthy volunteers (n = 22) were compared with patients (n = 99) with symptoms of gastroparesis. New DACS Fourier phase analysis software was developed. Results: GE was delayed (n = 53) or normal (n = 46) in patients. There was a linear correlation between the time for the stomach to empty 50% of the meal and the percentage total proximal and distal in-phase antral pixels at 30 min (r = 0.37, P = 0.0001) and 60 min (r = 0.26, P = 0.007). In healthy volunteers, the mean proximal-to-distal ratio of in-phase antral pixels increased from 1.67 (30 min) to 2.65 (120 min) (P = 0.035), and EF increased from 23% (30 min) to 32% (120 min) (P = 0.022). Multivariable regressions of percentage total proximal and distal in-phase antral pixels (30 min) and EF (60 min) were the best predictors of abnormal GE (adjusted odds ratio, 3.30 [95% CI, 1.21–9.00] and 2.97 [95% CI, 1.08–8.21], respectively). Conclusion: This study used Fourier phase analysis to analyze DACS in healthy volunteers and patients with symptoms of gastroparesis. In addition to establishing reference values, new physiologic information on antral motility was obtained. In healthy volunteers, there was an increasing proximal-to-distal ratio of in-phase antral pixels and antral EF over time after meal ingestion. The percentage total proximal and distal in-phase antral pixels at both 30 and 60 min correlated well with GE values for the time for the stomach to empty 50% of the meal. For symptomatic patients, the percentage total proximal and distal in-phase antral pixels at 30 min and the EF at 60 min after meal ingestion correlated with delayed GE on conventional GES. Thus, Fourier phase analysis of DACS appears to have potential to further aid in diagnosing gastric dysmotility in GES.
Footnotes
Published online Feb. 7, 2023.
This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
SNMMI members
Login to the site using your SNMMI member credentials
Individuals
Login as an individual user