Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleRadiation Safety

Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18F-FDG PET/CT

Razi Muzaffar, Elyse Koester, Sarah Frye, Saud Alenezi, Barbara B. Sterkel and Medhat M. Osman
Journal of Nuclear Medicine Technology March 2020, 48 (1) 63-67; DOI: https://doi.org/10.2967/jnmt.119.233296
Razi Muzaffar
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elyse Koester
2Division of Nuclear Medicine, St. Louis University Hospital, SSM Health, St. Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sarah Frye
3Medical Imaging and Radiation Therapeutics, Saint Louis University, St. Louis, Missouri; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Saud Alenezi
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Barbara B. Sterkel
4Diagnostic Imaging Service VA, St. Louis Health Care System, Saint Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Medhat M. Osman
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

At a time when reducing the radiation dose to patients and the public has become a major focus, we assessed the radiation exposure rate from patients after an 18F-FDG PET/CT scan and evaluated different interventions to reduce it. Methods: We enrolled 100 patients, divided into 2 groups. For both groups, the radiation dose rate was measured with an ionization survey meter immediately after the scan. For group 1, the patients then voided and their dose rate was measured again. For group 2, the patients waited 30 min before voiding, and we measured the dose rate before (group 2A) and after (group 2B) they voided. Results: In total, 74 of the 100 patients exceeded the 20 μSv/h (2 mR/h) threshold immediately after the scan. In group 1, the mean dose rate decreased by 20.0% from the postscan measurement, with 12 of 36 remaining at or above 20 μSv/h. In group 2A, the mean dose rate decreased by 23% from the postscan measurement, with 9 of 38 remaining at or above 20 μSv/h. In group 2B, the mean dose rate decreased by 35% from the postscan measurement, with 1 of 38 remaining at 20 μSv/h. Conclusion: Nearly 75% of patients undergoing an 18F-FDG PET/CT scan exceed 20 μSv/h when leaving the imaging facility. The most effective method to reduce radiation exposure was to have the patient void 30 min after the examination.

  • ALARA
  • PET/CT
  • radiation exposure
  • radiation safety

Footnotes

  • Published online Oct. 11, 2019.

View Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 48 (1)
Journal of Nuclear Medicine Technology
Vol. 48, Issue 1
March 1, 2020
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18F-FDG PET/CT
Razi Muzaffar, Elyse Koester, Sarah Frye, Saud Alenezi, Barbara B. Sterkel, Medhat M. Osman
Journal of Nuclear Medicine Technology Mar 2020, 48 (1) 63-67; DOI: 10.2967/jnmt.119.233296
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Reducing Radiation Exposure from PET Patients
  • National Diagnostic Reference Levels for Nuclear Medicine in Kuwait
  • Its Time to Celebrate!
  • Google Scholar

More in this TOC Section

  • Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand
  • Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand
  • Assessment of Area Radiation Dose for the National Cyclotron and PET Centre at Chulabhorn Hospital in Thailand
Show more RADIATION SAFETY

Similar Articles

  • Delivery Methods of Radiopharmaceuticals: Exploring Global Strategies to Minimize Occupational Radiation Exposure
  • Radiation Safety Certification: A Review
  • National Diagnostic Reference Levels for Nuclear Medicine in Kuwait
  • Nuclear Medicine Clinical Practice in the United States During the COVID-19 Era and Beyond
  • Technologist Approach to Global Dose Optimization
See more

Keywords

  • ALARA
  • PET/CT
  • radiation exposure
  • radiation safety
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18F-FDG PET/CT
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18F-FDG PET/CT
Razi Muzaffar, Elyse Koester, Sarah Frye, Saud Alenezi, Barbara B. Sterkel, Medhat M. Osman
Journal of Nuclear Medicine Technology Mar 2020, 48 (1) 63-67; DOI: 10.2967/jnmt.119.233296

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.