Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleSpecial Contribution

Technologist Approach to Global Dose Optimization

Pedro Fragoso Costa, Giorgio Testanera, Luca Camoni, Christelle Terwinghe; on behalf of the EANM Technologist Committee, Elizabeth A. Bailey; on behalf of the ANZSNM Technologists Special Interest Group, Norman E. Bolus; on behalf of the SNMMI Technologist Section and Tina M. Alden; on behalf of CAMRT
Journal of Nuclear Medicine Technology March 2019, 47 (1) 75-82; DOI: https://doi.org/10.2967/jnmt.118.218131
Pedro Fragoso Costa
1Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Giorgio Testanera
2Barts Health NHS Trust, Department of Nuclear Medicine, St. Bartholomew’s Hospital, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Luca Camoni
3Nuclear Medicine Unit, Department of Nuclear Medicine, Spedali Civili of Brescia, Brescia, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christelle Terwinghe
4Nuclear Medicine, University Hospitals Leuven, Leuven, Belgium
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elizabeth A. Bailey
5Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Norman E. Bolus
6Nuclear Medicine Technology Program, University of Alabama at Birmingham, Birmingham, Alabama; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tina M. Alden
7BC Cancer Agency, Vancouver, British Columbia, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Information

vol. 47 no. 1 75-82
DOI 
https://doi.org/10.2967/jnmt.118.218131
PubMed 
30413598

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Received for publication July 20, 2018
  • Accepted for publication September 25, 2018
  • Published online March 5, 2019.

Article Versions

  • previous version (November 9, 2018 - 09:05).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2019 by the Society of Nuclear Medicine and Molecular Imaging.

Author Information

  1. Pedro Fragoso Costa1,
  2. Giorgio Testanera2,
  3. Luca Camoni3,
  4. Christelle Terwinghe4 on behalf of the EANM Technologist Committee,
  5. Elizabeth A. Bailey5 on behalf of the ANZSNM Technologists Special Interest Group,
  6. Norman E. Bolus6 on behalf of the SNMMI Technologist Section and
  7. Tina M. Alden7 on behalf of CAMRT
  1. 1Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
  2. 2Barts Health NHS Trust, Department of Nuclear Medicine, St. Bartholomew’s Hospital, London, United Kingdom
  3. 3Nuclear Medicine Unit, Department of Nuclear Medicine, Spedali Civili of Brescia, Brescia, Italy
  4. 4Nuclear Medicine, University Hospitals Leuven, Leuven, Belgium
  5. 5Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
  6. 6Nuclear Medicine Technology Program, University of Alabama at Birmingham, Birmingham, Alabama; and
  7. 7BC Cancer Agency, Vancouver, British Columbia, Canada
  1. For correspondence or reprints contact: Pedro Fragoso Costa, Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany. E-mail: pedro.fragoso-costa@uni-due.de
View Full Text

Statistics from Altmetric.com

Article has an altmetric score of 1

See more details

Posted by 1 X users
24 readers on Mendeley

Cited By...

  • 3 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology
    Luca Camoni, Andrea Santos, Marieclaire Attard, Marius Ovidiu Mada, Agata Karolina Pietrzak, Sonja Rac, Sebastijan Rep, Christelle Terwinghe, Pedro Fragoso Costa
    European Journal of Hybrid Imaging 2020 4 1
  • National and local diagnostic reference levels for adult 18F-FDG and CT in Jordanian PET/CT: findings and implications in practice
    Qays Alhorani, Essam Alkhybari, Mohammad Rawashdeh, Akmal Sabarudin, Rukiah A Latiff, Akram Al-Ibraheem, Mazlyfarina Mohamad
    Journal of Radiological Protection 2024 44 1
  • A Comparison of Readings from Thermoluminescent Dosimeter Ring Badges Worn in Different Positions
    Keexia L. Osborne, Cybil J. Nielsen, John R. Bullock, S. Gregory Jennings
    Journal of Nuclear Medicine Technology 2020 48 4

Article usage

Article usage: November 2018 to April 2025

AbstractFullPdf
AbstractFullPdf
Nov 201815806
Dec 20189801
Jan 201911506
Feb 20198403
Mar 2019270310
Apr 201923659
May 2019253310
Jun 2019145512
Jul 20199303
Aug 20198512
Sep 20199611
Oct 20199124
Nov 20199518
Dec 20196505
Jan 20206405
Feb 20209643
Mar 202049106
Apr 202018712
May 2020493612
Jun 2020371411
Jul 2020302010
Aug 2020381622
Sep 202048159
Oct 2020511715
Nov 2020551312
Dec 2020241912
Jan 2021134812
Feb 2021105915
Mar 2021173739
Apr 202172212
May 2021133920
Jun 202153917
Jul 2021172018
Aug 2021162313
Sep 202115217
Oct 2021132735
Nov 2021162124
Dec 2021212816
Jan 2022153112
Feb 2022174117
Mar 2022193313
Apr 2022193620
May 2022173131
Jun 2022101717
Jul 2022141710
Aug 202292711
Sep 2022203721
Oct 2022122710
Nov 202292312
Dec 202210912
Jan 202316145
Feb 2023122111
Mar 2023153017
Apr 2023164113
May 20237187
Jun 20239268
Jul 2023192813
Aug 202351810
Sep 202391914
Oct 20234434
Nov 2023108715
Dec 2023524214
Jan 202414182135
Feb 20249184
Mar 2024102251
Apr 202444930
May 2024167621
Jun 2024107232
Jul 2024124720
Aug 2024124520
Sep 20241510439
Oct 2024247131
Nov 2024275417
Dec 202423315
Jan 202571621
Feb 20251319728
Mar 20251113328
Apr 2025197929
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 47 (1)
Journal of Nuclear Medicine Technology
Vol. 47, Issue 1
March 1, 2019
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Technologist Approach to Global Dose Optimization
Pedro Fragoso Costa, Giorgio Testanera, Luca Camoni, Christelle Terwinghe, Elizabeth A. Bailey, Norman E. Bolus, Tina M. Alden
Journal of Nuclear Medicine Technology Mar 2019, 47 (1) 75-82; DOI: 10.2967/jnmt.118.218131
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Abstract
    • DOSE REDUCTION PRINCIPLES
    • PEDIATRIC PATIENTS
    • HYBRID IMAGING
    • CARDIAC IMAGING
    • NEW TRENDS IN RADIONUCLIDE THERAPY
    • PET OCCUPATIONAL EXPOSURE
    • EANM INITIATIVES FOR DOSE OPTIMIZATION
    • AUSTRALIAN AND NEW ZEALAND SOCIETY OF NUCLEAR MEDICINE INITIATIVES FOR DOSE OPTIMIZATION
    • SNMMI INITIATIVES FOR DOSE OPTIMIZATION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • A Comparison of Readings from Thermoluminescent Dosimeter Ring Badges Worn in Different Positions
  • Looking Forward to 2019
  • Google Scholar

More in this TOC Section

  • Gender and Ethnicity Bias of Text-to-Image Generative Artificial Intelligence in Medical Imaging, Part 1: Preliminary Evaluation
  • Gender and Ethnicity Bias of Text-to-Image Generative Artificial Intelligence in Medical Imaging, Part 2: Analysis of DALL-E 3
  • The Impact of the Coronavirus Disease 2019 Pandemic on the Clinical Environment
Show more Special Contribution

Similar Articles

Keywords

  • radiation safety
  • Scope of Practice
  • competencies
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Technologist Approach to Global Dose Optimization
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Technologist Approach to Global Dose Optimization
Pedro Fragoso Costa, Giorgio Testanera, Luca Camoni, Christelle Terwinghe, Elizabeth A. Bailey, Norman E. Bolus, Tina M. Alden
Journal of Nuclear Medicine Technology Mar 2019, 47 (1) 75-82; DOI: 10.2967/jnmt.118.218131

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.