Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherIMAGING

Practical Aspects of 18F-FDG PET When Receiving 18F-FDG from a Distant Supplier

Jaylene Ducharme, Andrew L. Goertzen, Judy Patterson and Sandor Demeter
Journal of Nuclear Medicine Technology September 2009, 37 (3) 164-169; DOI: https://doi.org/10.2967/jnmt.109.062950
Jaylene Ducharme
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrew L. Goertzen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Judy Patterson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sandor Demeter
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Tables

  • Additional Files
    • View popup
    TABLE 1

    PET/CT Scan Totals by Year

    YearAverage no. of scans/moSD of averageMinimum no./moMaximum no./mo
    2005–200654.924.31586
    2006–200775.612.35489
    2007–200882.812.863110
    • View popup
    TABLE 2

    PET/CT Scheduled and Actual Scan Numbers by Year

    YearScheduled scan daysActual scan daysScheduled scansActual scansPercentage of scans cancelled18F-FDG production problems (d)Transport problems (d)
    2005–200613412375565912.71313
    2006–20071711551,04990713.5188
    2007–20081831531,24999320.53712
    • View popup
    TABLE 3

    Reasons for PET/CT Scan Cancellations by Year

    YearScans cancelled because of 18F-FDG production problemsScans cancelled because of transport problemsScans cancelled because of PET system downtimeScans cancelled by patient
    2005–20064532316
    2006–20078428030
    2007–2008165571024
    • View popup
    TABLE 4

    Alternative Scanning Schedules Based on Amount of 18F-FDG Shipped (Standard Dose, 444 MBq)

    Scanning schedulePatient no.Time slotInjection timeShipped activity required (GBq) to inject all patients up to and including that slot
    Routine112:0012:303
    212:2512:556
    312:5013:2010
    413:4014:1518
    514:1514:4525
    614:4515:1534
    715:2015:5045
    815:4516:2560
    Delayed shipment to 16:00 h arrival115:1016:0013.4
    215:2516:0528.8
    315:4016:1042.4
    416:1517:0063.6
    516:4517:2584.8
    617:1518:00106
    Emergency low shipment111:3012:153
    211:5012:206
    312:1012:4010
    412:4513:1515
    513:1513:4521
    613:4514:1528
    714:1514:4534
    814:4515:1545
    • View popup
    TABLE 5

    Patient Injection Calculator for 10-GBq-Activity 18F-FDG Shipment

    Patient no.Time since previous injection (min)Injection timeActivity available (MBq)Injected dose (MBq)Residual activity (MBq)
    1013:0010,0004449,556
    21513:158,6944448,250
    33013:456,8294446,385
    46014:454,3754443,931
    53515:203,1534442,709
    63515:552,1734441,729
    74016:351,344444900
    87517:50561444117
    93018:2097444−347
    • View popup
    TABLE 6

    Patient Injection Calculators for 5-GBq-Activity 18F-FDG Shipment

    Injection schedulePatient no.Time since previous injection (min)Injection timeActivity available (MBq)Injected dose (MBq)Residual activity (MBq)
    Normal1013:005,0004444,556
    21513:154,1454443,701
    33013:453,0644442,620
    46014:451,7954441,351
    53515:201,084444640
    63515:5551344469
    74016:3554444−390
    Alternative1013:005,0004444,556
    2013:004,5564444,112
    3013:004,1124443,668
    44513:452,7624442,318
    53514:201,8604441,416
    63514:551,135444691
    74015:3553744493
    87516:5058444−386

Additional Files

  • Tables
  • Supplemental Data

    Files in this Data Supplement:

    • Supplemental Table 1
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 37 (3)
Journal of Nuclear Medicine Technology
Vol. 37, Issue 3
September 2009
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Practical Aspects of 18F-FDG PET When Receiving 18F-FDG from a Distant Supplier
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Practical Aspects of 18F-FDG PET When Receiving 18F-FDG from a Distant Supplier
Jaylene Ducharme, Andrew L. Goertzen, Judy Patterson, Sandor Demeter
Journal of Nuclear Medicine Technology Sep 2009, 37 (3) 164-169; DOI: 10.2967/jnmt.109.062950

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Practical Aspects of 18F-FDG PET When Receiving 18F-FDG from a Distant Supplier
Jaylene Ducharme, Andrew L. Goertzen, Judy Patterson, Sandor Demeter
Journal of Nuclear Medicine Technology Sep 2009, 37 (3) 164-169; DOI: 10.2967/jnmt.109.062950
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • CONCLUSION
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Robustness of 18F-FDG PET Radiomic Features in Lung Cancer: Impact of Advanced Reconstruction Algorithm
Show more Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire