Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherRADIOPHARMACY

Stability of Stabilized 99mTc-d,l-HMPAO Stored in Vials and Syringes

Maria del Carmen Plancha-Mansanet, Elisa Caballero-Calabuig, Jesús Félix-Fontestad, María Dolores Reyes-Ojeda, Pablo Sopena-Novales, Pedro Abreu-Sánchez, Maria del Carmen Cano-Terol and Ramón Sopena-Monforte
Journal of Nuclear Medicine Technology December 2008, 36 (4) 213-216; DOI: https://doi.org/10.2967/jnmt.108.053488
Maria del Carmen Plancha-Mansanet
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elisa Caballero-Calabuig
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jesús Félix-Fontestad
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
María Dolores Reyes-Ojeda
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pablo Sopena-Novales
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pedro Abreu-Sánchez
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maria del Carmen Cano-Terol
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ramón Sopena-Monforte
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • FIGURE 1. 
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1. 

    Percentage of RCP of stabilized 99mTc-d,l-HMPAO over time in both groups of labeling activities and forms of storage.

  • FIGURE 2. 
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2. 

    Percentage of radiochemical impurities in stabilized 99mTc-d,l-HMPAO over time in vials and syringes (mean ± SD; n = 10).

Tables

  • Figures
    • View popup
    TABLE 1

    Effect of Labeling Activity and Storage Form on RCP of Stabilized 99mTc-d,l-HMPAO over Time

    1,110 MBq2,600–3,700 MBq
    Time (h)VialSyringeNeedleVialSyringeNeedle
    093.1 ± 1.6NANA91.4 ± 1.0NANA
    292.1 ± 0.989.8 ± 2.174.2 ± 5.089.0 ± 1.485.9 ± 1.473.3 ± 8.5
    491.1 ± 1.088.7 ± 2.059.8 ± 5.185.3 ± 3.080.2 ± 3.157.1 ± 4.5
    • NA = not applicable.

    • Values represent percentage of RCP (mean ± SD); n = 10. P < 0.01 for vials between both groups of labeling activities at all times. P < 0.01 for syringes in both groups of labeling activities at 2 and 4 h. P < 0.01 between vials and syringes in both groups of labeling activities at 2 and 4 h. P < 0.01 between vials and needles in both groups of labeling activities at 2 and 4 h. P < 0.01 between syringes and needles in both groups of labeling activities at 2 and 4 h.

    • View popup
    TABLE 2

    Effect of Labeling Activity and Storage Form on Radiochemical Impurities in Stabilized 99mTc-d,l-HMPAO in Vials and Syringes over Time

    1,110 MBq2,600–3,700 MBq
    99mTcO2 + secondary 99mTc-HMPAO99mTcO4−99mTcO2 + secondary 99mTc-HMPAO99mTcO4−
    Time (h)VialSyringeVialSyringeVialSyringeVialSyringe
    04.8 ± 0.9NA2.1 ± 0.9NA6.2 ± 1.2NA2.3 ± 0.7NA
    25.5 ± 0.96.2 ± 1.22.4 ± 0.54.0 ± 1.67.0 ± 1.48.1 ± 1.54.1 ± 1.26.0 ± 1.2
    46.1 ± 0.86.3 ± 0.92.8 ± 0.65.0 ± 1.78.6 ± 1.79.3 ± 1.96.2 ± 1.710.4 ± 2.5
    • NA = not applicable.

    • Values represent percentage of radiochemical impurities (mean ± SD); n = 10. P < 0.01 for 99mTcO2 + secondary 99mTc-HMPAO and 99mTcO4− between both groups of activities in vial and syringe at all times. P > 0.05 for 99mTcO4− between both groups of labeling activities in vial at t = 0.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 36 (4)
Journal of Nuclear Medicine Technology
Vol. 36, Issue 4
December 2008
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Stability of Stabilized 99mTc-d,l-HMPAO Stored in Vials and Syringes
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Stability of Stabilized 99mTc-d,l-HMPAO Stored in Vials and Syringes
Maria del Carmen Plancha-Mansanet, Elisa Caballero-Calabuig, Jesús Félix-Fontestad, María Dolores Reyes-Ojeda, Pablo Sopena-Novales, Pedro Abreu-Sánchez, Maria del Carmen Cano-Terol, Ramón Sopena-Monforte
Journal of Nuclear Medicine Technology Dec 2008, 36 (4) 213-216; DOI: 10.2967/jnmt.108.053488

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Stability of Stabilized 99mTc-d,l-HMPAO Stored in Vials and Syringes
Maria del Carmen Plancha-Mansanet, Elisa Caballero-Calabuig, Jesús Félix-Fontestad, María Dolores Reyes-Ojeda, Pablo Sopena-Novales, Pedro Abreu-Sánchez, Maria del Carmen Cano-Terol, Ramón Sopena-Monforte
Journal of Nuclear Medicine Technology Dec 2008, 36 (4) 213-216; DOI: 10.2967/jnmt.108.053488
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Validation of an Ergonomic Method of Withdrawing 99mTc-Radiopharmaceuticals
  • Google Scholar

More in this TOC Section

  • Miniaturized Radiochemical Purity Testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-Tetrofosmin