Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherIMAGING

Contamination of a Bracelet Following Iodine-131 Therapy: A Case Report

Bohdan Bybel, Wendy Beebe, Benedict Y. Kim and Charles Faiman
Journal of Nuclear Medicine Technology December 2000, 28 (4) 257-258;
Bohdan Bybel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wendy Beebe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Benedict Y. Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Charles Faiman
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

A 73-y-old patient who had thyroid carcinoma had a post-treatment, whole-body 131I scan. The scan demonstrated an artifact caused by a bracelet contaminated with radioactive perspiration. This finding resulted in an artifact on the scan and had potential radiation safety implications.

  • iodine-131
  • artifact
  • perspiration
  • radiation exposure

This patient was a 73-y-old woman who was diagnosed with thyroid carcinoma in 1992. She had a total thyroidectomy and radioiodine ablation with 150 mCi (5.55 GBq). A subsequent whole-body scan showed no residual disease. Seven years later, because of an increasing thyroglobulin level and a suspicion of recurrent disease, a diagnostic scan was performed and followed by a 150-mCi 131I treatment. At 11 d post-treatment, the patient returned for a whole-body scan.

In addition to the neck uptake, the scan showed linear increased uptake across the right forearm (Fig. 1). A gold bracelet on the arm corresponded to the area of increased activity. The patient stated that she always wore that particular piece of jewelry and had not taken it off (except when washing herself) since her treatment dose. The gold bracelet itself was unremarkable having been purchased several years ago in a department store.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Post-131I therapy whole-body scan. Linear uptake at the right forearm was present.

The bracelet was removed and imaged under the 364-keV peak (Fig. 2). It also was monitored with a pancake probe monitor. The initial reading was 20 mR/h. After it was washed thoroughly with water and Radiactwash (Biodex, Shirley, NY), it was remeasured. The subsequent reading was 4 mR/h. These findings would suggest that the radioactivity was related to radioactive perspiration that was present on the bracelet. The bracelet was put in a plastic container and returned to the patient with instructions not to wear it or lend it to anyone for several weeks until the radioactivity had decayed.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Image of patient's bracelet.

DISCUSSION

Several studies have described potentially false-positive findings after radioiodine treatment. Most such artifacts are due to perspiration (1–5). Cases where saliva, urine, or other body fluids can produce artifacts also have been described (6–12). In the present case, the appearance was not typical of a metastatic lesion and was identified correctly as an artifact with little difficulty. In cases such as this one, the potential problem of unwanted radiation exposure from contaminated objects also must be addressed.

CONCLUSION

Radioactive contamination from perspiration is important to recognize, not only from a diagnostic point of view but also because of the potential of unwanted radiation exposure.

Footnotes

  • For correspondence or reprints contact: Dr. Bohdan Bybel, Department of Nuclear Medicine, Cleveland Clinic Foundation, 9500 Euclid Gb3, Cleveland, OH 44195; Phone: 216-444-2099; E-mail: bybelb{at}ccf.org.

REFERENCES

  1. ↵
    Bakheet SM, Hammami MM. Spurious thyroid cancer bone metastases on radioiodine scan due to external contamination. Eur J Rad. 1993;16:239–242.
  2. Bakheet S, Hammami MM. Spurious lung metastases on radioiodine thyroid and whole body imaging. Clin Nuc Med. 1993;18:307–312.
    OpenUrlPubMed
  3. Camponovo EJ, Goyer PF, Silverman ED, et al. Axillary iodine-131 accumulation due to perspiration. Clin Nuc Med. 1989;14:762–763.
    OpenUrlPubMed
  4. Joyce WT, Cowan RJ. A potential false-positive posttherapy radioiodine scan secondary to I-131 excretion in perspiration. Clin Nuc Med. 1995;20:368–369.
    OpenUrlPubMed
  5. ↵
    Abdel-Dayem HM, Halker K, El Sayed M. The radioactive wig in iodine-131 whole body imaging. Clin Nuc Med. 1984;9:454–455.
    OpenUrlPubMed
  6. ↵
    Bakheet SM, Powe J, Hammami MM. Radioiodine uptake in the chest. J Nuc Med. 1997;38:984–987.
    OpenUrlFREE Full Text
  7. Bakheet SM, Hammami MM. False-positive radioiodine whole-body scan in thyroid cancer patients due to unrelated pathology. Clin Nuc Med. 1994;19:325–329.
    OpenUrlCrossRefPubMed
  8. Pochis WT, Krasnow AZ, Isitman AT, et al. The radioactive handkerchief sign. A contamination artifact in I-131 imaging for metastatic thyroid carcinoma. Clin Nuc Med. 1990;15:491–494.
    OpenUrlPubMed
  9. Park HM, Tarver RD, Schauwecker DS, Burt R. Spurious thyroid cancer metastasis: saliva contamination artifact in high dose iodine-131 metastases survey. J Nuc Med. 1986;27:634–636.
    OpenUrlAbstract/FREE Full Text
  10. Gritters LS, Wissing J, Gross MD, Shapiro B. Extensive salivary contamination due to concurrent use of chewing tobacco during I-131 radioablative therapy. Clin Nuc Med. 1993;18:115–117.
    OpenUrlPubMed
  11. Wiseman J. Bony metastases from thyroid carcinoma or contaminations. Clin Nuc Med. 1984;9:363.
    OpenUrlPubMed
  12. ↵
    Tyson JW, Wilkinson RH Jr, Witherspoon LR, et al. False-positive 131-I total-body scans. J Nuc Med. 1974;15:1052–1053.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 28 (4)
Journal of Nuclear Medicine Technology
Vol. 28, Issue 4
December 1, 2000
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Contamination of a Bracelet Following Iodine-131 Therapy: A Case Report
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Contamination of a Bracelet Following Iodine-131 Therapy: A Case Report
Bohdan Bybel, Wendy Beebe, Benedict Y. Kim, Charles Faiman
Journal of Nuclear Medicine Technology Dec 2000, 28 (4) 257-258;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Contamination of a Bracelet Following Iodine-131 Therapy: A Case Report
Bohdan Bybel, Wendy Beebe, Benedict Y. Kim, Charles Faiman
Journal of Nuclear Medicine Technology Dec 2000, 28 (4) 257-258;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • False-Positive Scalp Activity in 131I Imaging Associated with Hair Coloring
  • Iodine 131 Uptake Related to Hair Dyeing
  • The Helmet Sign: Physiologic Radioactive Accumulation After 131I Therapy--A Case Report
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire