Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleRadiopharmacy

Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur

Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa’ Aminudin and Kee Wei Lau
Journal of Nuclear Medicine Technology February 2025, jnmt.124.268886; DOI: https://doi.org/10.2967/jnmt.124.268886
Ren Yi Fong
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nurul Maisara Jaffar
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rachel Jen Lyn Chung
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hui Ling Tong
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Syifaa’ Aminudin
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kee Wei Lau
Nuclear Pharmacy, Hospital Kuala Lumpur, Kuala Lumpur, Malaysia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Myocardial perfusion imaging using the radiopharmaceutical [99mTc]Tc-tetrofosmin plays a crucial role in diagnosing cardiac conditions. However, variations in the residual activity of [99mTc]Tc-tetrofosmin in plastic syringes after administration may impact imaging quality and patient safety. This study aimed to evaluate the residual activity of [99mTc]Tc-tetrofosmin in plastic syringes after administration during routine nuclear medicine procedures at Hospital Kuala Lumpur, assessing compliance with department protocols and variability among different syringe brands. Methods: A single-center prospective observational study was conducted using stratified quota sampling, encompassing 396 samples across 3 syringe brands (SJ, BD, and Ciringe). Residual activity was measured immediately after administration, and statistical analysis was performed to compare brands and assess compliance with the department dosage protocol range of 333–555 MBq. Results: All injected activities aligned with the department protocol dose, with a mean effective activity of 451.23 ± 30.73 MBq and a mean residual activity of 12.63% ± 4.73%. However, variability in residual activity was observed among syringe brands. BD exhibited the highest mean residual activity (16.45%), significantly differing from SJ (9.95%) and Ciringe (11.50%) (P < 0.001). Conclusion: Rigorous syringe selection is crucial in myocardial perfusion imaging procedures to minimize residual activity and ensure compliance with dosimetry standards, emphasizing the importance of integrating pharmacy practices into nuclear medicine protocols. Standardized protocols and quality assurance measures are essential to optimize imaging outcomes and prioritize patient safety. These findings highlight the importance of ongoing monitoring and interdisciplinary collaboration to navigate residual activity management effectively in routine nuclear medicine practice.

  • myocardial perfusion imaging
  • [99mTc]Tc-tetrofosmin
  • residual activity
  • syringe selection
  • dosimetry compliance
  • patient safety

Footnotes

  • Published online Feb. 5, 2025.

View Full Text

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

SNMMI members

SNMMI Member Login

Login to the site using your SNMMI member credentials

Individuals

Non-Member Login

Login as an individual user

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (1)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 1
March 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur
Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa’ Aminudin, Kee Wei Lau
Journal of Nuclear Medicine Technology Feb 2025, jnmt.124.268886; DOI: 10.2967/jnmt.124.268886

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Assessment of Residual [99mTc]Tc-Tetrofosmin Activity in Routine Nuclear Medicine Practice at Hospital Kuala Lumpur
Ren Yi Fong, Nurul Maisara Jaffar, Rachel Jen Lyn Chung, Hui Ling Tong, Syifaa’ Aminudin, Kee Wei Lau
Journal of Nuclear Medicine Technology Feb 2025, jnmt.124.268886; DOI: 10.2967/jnmt.124.268886
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Miniaturized Radiochemical Purity Testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-Tetrofosmin
  • Changes in Patterns of 99mTc-Macroaggregated Albumin Use Between 2000 and 2015
  • Particle-Size and Radiochemical Purity Evaluations of Filtered 99mTc-Sulfur Colloid Prepared with Different Heating Times
Show more Radiopharmacy

Similar Articles

Keywords

  • myocardial perfusion imaging
  • [99mTc]Tc-tetrofosmin
  • residual activity
  • syringe selection
  • dosimetry compliance
  • patient safety
SNMMI