Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleBasic Science Investigations

Rotation Radius Dependence of 123I-FP-CIT and 123I-IBZM SPECT Uptake Ratios: A Monte Carlo Study

Anne Larsson, Susanna Jakobson Mo and Katrine Riklund
Journal of Nuclear Medicine Technology October 2012, jnmt.112.108555; DOI: https://doi.org/10.2967/jnmt.112.108555
Anne Larsson
1Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Susanna Jakobson Mo
2Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå, Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Katrine Riklund
2Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå, Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Article Information

jnmt.112.108555
DOI 
https://doi.org/10.2967/jnmt.112.108555
PubMed 
23048208

Published By 
Society of Nuclear Medicine
Print ISSN 
0091-4916
Online ISSN 
1535-5675
History 
  • Published online October 9, 2012.

Article Versions

  • You are currently viewing a previous version of this article (October 9, 2012 - 05:29).
  • View the most recent version of this article
Copyright & Usage 
© 2012 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Author Information

  1. Anne Larsson1,
  2. Susanna Jakobson Mo2 and
  3. Katrine Riklund2
  1. 1Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden; and
  2. 2Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå, Sweden
  1. For correspondence contact: Anne Larsson, Department of Radiation Sciences, Radiation Physics, Umeå University, SE 901 87 Umeå 90185, Sweden. E-mail: anne.larsson.stromvall{at}vll.se

Statistics from Altmetric.com

Cited By...

  • 10 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • [123I]FP-CIT ENC-DAT normal database: the impact of the reconstruction and quantification methods
    Livia Tossici-Bolt, John C. Dickson, Terez Sera, Jan Booij, Susanne Asenbaun-Nan, Maria C. Bagnara, Thierry Vander Borght, Cathrine Jonsson, Robin de Nijs, Swen Hesse, Pierre M. Koulibaly, Umit O. Akdemir, Michel Koole, Klaus Tatsch, Andrea Varrone
    EJNMMI Physics 2017 4 1
  • 123I-FP-Cit and 123I-IBZM SPECT uptake in a prospective normal material analysed with two different semiquantitative image evaluation tools
    Susanna Jakobson Mo, Anne Larsson, Jan Linder, Richard Birgander, Lars Edenbrandt, Hans Stenlund, Lars Forsgren, Katrine Riklund
    Nuclear Medicine Communications 2013 34 10
  • Radius dependence of FP-CIT quantification: a Monte Carlo-based simulation study
    Walter Koch, Peter Bartenstein, Christian la Fougère
    Annals of Nuclear Medicine 2014 28 2
  • Pre- and Postsynaptic Dopamine SPECT in Idiopathic Parkinsonian Diseases: A Follow-Up Study
    Susanna Jakobson Mo, Jan Linder, Lars Forsgren, Henrik Holmberg, Anne Larsson, Katrine Riklund
    BioMed Research International 2013 2013
  • Accuracy of Visual Assessment of Dopamine Transporter Imaging in Early Parkinsonism
    Susanna Jakobson Mo, Jan Linder, Lars Forsgren, Katrine Riklund
    Movement Disorders Clinical Practice 2015 2 1
  • Fractional Anisotropy and Mean Diffusion as Measures of Dopaminergic Function in Parkinson’s Disease: Challenging Results
    Niklas Lenfeldt, Johan Eriksson, Björn Åström, Lars Forsgren, Susanna Jakobson Mo
    Journal of Parkinson’s Disease 2016 7 1
  • PITX3 genotype and risk of dementia in Parkinson's disease: A population-based study
    David Bäckström, Magdalena Eriksson Domellöf, Gabriel Granåsen, Jan Linder, Sofia Mayans, Eva Elgh, Susanna Jakobson Mo, Lars Forsgren
    Journal of the Neurological Sciences 2017 381
  • Long-term dopamine transporter imaging in Parkinson’s disease treated with zona incerta stimulation
    Susanna Jakobson Mo, Jan Linder, Patric Blomstedt, Gabriel Granåsen, Lars Forsgren, Marwan Hariz
    Nuclear Medicine Communications 2016 37 5
  • 3D-OSEM and FP-CIT SPECT quantification
    Walter Koch, Peter Bartenstein, Christian la Fougère
    Nuclear Medicine Communications 2013 34 10
  • The effect of scatter correction and radius of rotation on semiquantitative measurements in SPECT 123I-FP-CIT imaging. A phantom study
    Emmanouil Papanastasiou, Christina Katsiva, Argyrios Doumas, Georgios Gerasimou, Anastasios Siountas
    Physica Medica 2020 69

Article usage

Article usage: October 2012 to April 2025

AbstractFullPdf
Oct 20125002
Nov 20127200
Dec 201221124
Jan 201321509
Feb 20132671117
Mar 2013951614
Apr 2013591013
May 2013661211
Jun 201340910
Jul 20134834
Aug 20133523
Sep 20133944
Oct 20133524
Nov 20134023
Dec 20132935
Jan 20143033
Feb 20143995
Mar 20142285
Apr 20143273
May 20142747
Jun 20143249
Jul 20141168
Aug 201411611
Sep 201433516
Oct 201421311
Nov 20142318
Dec 20141415
Jan 201519452
Feb 201510465
Mar 20152269
Apr 20151946
May 201522114
Jun 20151364
Jul 20151738
Aug 20151652
Sep 20151615
Oct 20151400
Nov 20151311
Dec 20151593
Jan 20162988
Feb 2016974
Mar 201623413
Apr 2016211417
May 20163397
Jun 20161486
Jul 201614626
Aug 201618712
Sep 201621914
Oct 2016311518
Nov 2016311423
Dec 201686688
Jan 2017312121
Feb 201737218
Mar 201718122
Apr 201791114
May 2017214718
Jun 2017174514
Jul 201795619
Aug 2017143117
Sep 2017191110
Oct 201724189
Nov 20172066
Dec 2017822
Jan 20181283
Feb 2018313
Mar 20181339
Apr 20181478
May 201828310
Jun 2018502
Jul 20181765
Aug 2018835
Sep 2018307
Oct 20183014
Nov 20184112
Dec 20181114
Jan 20196114
Feb 20197214
Mar 20196014
Apr 20196216
May 20196311
Jun 2019418
Jul 20197224
Aug 2019414
Sep 2019945
Oct 20195219
Nov 20191255
Dec 2019501
Jan 2020512
Feb 2020834
Mar 20201893
Apr 20201003
May 2020613
Jun 2020912
Jul 2020503
Aug 202011111
Sep 20201305
Oct 20201322
Nov 2020774
Dec 20203210
Jan 2021556
Feb 2021788
Mar 20210192
Apr 2021241
May 20216122
Jun 2021437
Jul 20214613
Aug 2021492
Sep 202131159
Oct 20213839
Nov 202110719
Dec 20219158
Jan 2022684
Feb 20227125
Mar 2022696
Apr 20224104
May 20222715
Jun 2022335
Jul 2022364
Aug 2022866
Sep 20222176
Oct 2022357
Nov 2022862
Dec 2022020
Jan 2023404
Feb 2023531
Mar 2023097
Apr 20232111
May 2023326
Jun 2023776
Jul 20232711
Aug 2023286
Sep 2023533
Oct 2023485
Nov 2023378
Dec 20233148
Jan 2024090
Feb 2024664
Mar 20241830
Apr 20241821
May 20243489
Jun 2024115117
Jul 202461018
Aug 20246273
Sep 2024122636
Oct 202482014
Nov 20241296
Dec 2024179
Jan 20254136
Feb 20250436
Mar 202584021
Apr 2025132415
Next
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (1)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 1
March 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Rotation Radius Dependence of 123I-FP-CIT and 123I-IBZM SPECT Uptake Ratios: A Monte Carlo Study
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Rotation Radius Dependence of 123I-FP-CIT and 123I-IBZM SPECT Uptake Ratios: A Monte Carlo Study
Anne Larsson, Susanna Jakobson Mo, Katrine Riklund
Journal of Nuclear Medicine Technology Oct 2012, jnmt.112.108555; DOI: 10.2967/jnmt.112.108555

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Rotation Radius Dependence of 123I-FP-CIT and 123I-IBZM SPECT Uptake Ratios: A Monte Carlo Study
Anne Larsson, Susanna Jakobson Mo, Katrine Riklund
Journal of Nuclear Medicine Technology Oct 2012, jnmt.112.108555; DOI: 10.2967/jnmt.112.108555
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

Similar Articles

Keywords

  • SPECT
  • rotation radius
  • 123I
  • FP-CIT
  • IBZM
SNMMI

© 2025 SNMMI

Powered by HighWire