Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticlePractical Protocols

Cardiac Sarcoidosis Imaging: PET

Diane K. Soulek, Mary Beth Farrell, Kathy S. Thomas, Eleanor S. Mantel and Jessica Settle
Journal of Nuclear Medicine Technology June 2025, 53 (2) 113-115; DOI: https://doi.org/10.2967/jnmt.125.269838
Diane K. Soulek
CNMT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mary Beth Farrell
CNMT, NCT, FSNMMI-TS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kathy S. Thomas
CNMT, PET, FSNMMI-TS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eleanor S. Mantel
CNMT, NCT, RT(N), FSNMMI-TS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jessica Settle
CNMT, RT(N), FSNMMI-TS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Tables

    • View popup
    TABLE 1.

    Radiopharmaceutical Identity, Dose, and Route of Administration

    IdentityDoseRoute of administration
    18F-FDG370 MBq (10 mCi)Intravenous
    Range: 185–555 MBq (5–15 mCi)
    • View popup
    TABLE 2.

    Pharmaceutical Identity, Dose, and Route of Administration

    IdentityDoseRoute of administration
    Unfractionated heparin10 IU/kg 30 min prior + 5 IU/kgIntravenous
    15 min prior or 50 IU/kg
    15 min before radiotracer administration
    • View popup
    TABLE 3.

    Acquisition Parameters: PET or PET/CT

    ParameterSpecificationStandard/preferred/optional
    Camera typePET/CTPreferred
    PETStandard
    Energy peak511 keVStandard
    Injection-to-imaging time60–90 minStandard
    Attenuation correctionPET/CT: CT acquisitionStandard
    PET: cesium or germanium sourcesStandard
    Patient positionSupineStandard
    Arm positionArms overheadStandard
    Acquisition mode2- or 3-dimensionalStandard
    Number of bed positionsVariesStandard
    Time/bed positionPartial whole-body scan:Standard
     2-dimensional: 4 min
     3-dimensional: 3 min
    Dedicated cardiac scan:
     2-dimensional: 20–30 min
     3-dimensional: 10 min
    ViewChest, including the lungs and mediastinumStandard
    CT acquisitionPer the manufacturer’s recommendations for attenuation correction or diagnostic imagingOptional
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (2)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 2
June 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Cardiac Sarcoidosis Imaging: PET
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Cardiac Sarcoidosis Imaging: PET
Diane K. Soulek, Mary Beth Farrell, Kathy S. Thomas, Eleanor S. Mantel, Jessica Settle
Journal of Nuclear Medicine Technology Jun 2025, 53 (2) 113-115; DOI: 10.2967/jnmt.125.269838

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Cardiac Sarcoidosis Imaging: PET
Diane K. Soulek, Mary Beth Farrell, Kathy S. Thomas, Eleanor S. Mantel, Jessica Settle
Journal of Nuclear Medicine Technology Jun 2025, 53 (2) 113-115; DOI: 10.2967/jnmt.125.269838
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • RATIONALE
    • CLINICAL INDICATIONS
    • CONTRAINDICATIONS
    • PATIENT PREPARATION/EDUCATION
    • PROTOCOL/ACQUISITION INSTRUCTIONS
    • IMAGE PROCESSING
    • ADJUNCT IMAGING/INTERVENTIONS
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Myocardial Sympathetic Innervation Imaging
  • Technegas Ventilation Lung Imaging in the United States
Show more Practical Protocols

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire