Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging
Open Access

Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial

Sanjit O. Tewari, Nina Tamirisa, Guofan Xu and Yang Lu
Journal of Nuclear Medicine Technology June 2024, 52 (2) 104-106; DOI: https://doi.org/10.2967/jnmt.123.266143
Sanjit O. Tewari
1Department of Nuclear Medicine, University of Texas M.D. Anderson Cancer Center, Houston, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nina Tamirisa
2Department of Breast Surgery, University of Texas M.D. Anderson Cancer Center, Houston, Texas
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Guofan Xu
1Department of Nuclear Medicine, University of Texas M.D. Anderson Cancer Center, Houston, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yang Lu
1Department of Nuclear Medicine, University of Texas M.D. Anderson Cancer Center, Houston, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Breast lymphoscintigraphy is commonly performed before initial surgical intervention and surgical staging in the setting of breast cancer. Breast lymphoscintigraphy injections can often be quite painful and are routinely performed without any anesthesia or analgesia, thus representing a significant unmet need for the breast cancer population. Although vapocoolants have been previously available, they have typically been used on intact skin and not been recommended for sterile procedures. Methods: Thirty consecutive patients were enrolled in our prospective study of which 29 received vapocoolant analgesia in the setting of breast lymphoscintigraphy. Patients were given a postinjection questionnaire that included a self-reported pain score and boolean question regarding whether they would recommend vapocoolant for future patients. Results: The lymposcintigraphy procedure was successful in 100% of cases with an ipsilateral axillary node identified on average within 2.4 h of injection (median, 1 h; range 1–4.5 h). The average self-reported pain score was 1.98 (median, 1; range, 1–10). Conclusion: Vapocoolant analgesia in the setting of breast lymphoscintigraphy is feasible, does not appear to compromise lymphoscintigraphy, and appears to be associated with generally low self-reported pain scores.

  • breast
  • oncology
  • breast cancer
  • lymphoscintigraphy
  • vapocoolant

Breast lymphoscintigraphy is commonly performed before initial surgical interventions and surgical staging in the setting of breast cancer. Although breast lymphoscintigraphy may also be performed perioperatively under general anesthesia, by performing lymphoscintigraphy preoperatively, breast surgeons are often able to better plan their surgical staging procedures by prospectively being aware if there is indeed a draining lymph node of interest, the number of such lymph nodes, and the anatomic locations to investigate. In addition, performing breast lymphoscintigraphy as a separate preoperative procedure allows markedly increased time for radiotracer transit, as patients are often imaged for several hours and can be reassessed intraoperatively, with the surgery often scheduled for the following day.

Pain from breast lymphoscintigraphy is considered multifactorial, with the pathophysiology likely including stretching of skin layers and the acidity of the injectant, with the pH usually ranging from 3.5 to 6.0 (1). Several previously investigated interventions in breast lymphoscintigraphy include use of topical lidocaine (2) and buffered lidocaine (3,4), among others. However, use of intradermal buffered lidocaine, sometimes itself painful, requires 2 separate needle sticks and may require additional volume administration, which may accentuate skin stretching, whereas use of topical lidocaine requires significant time to be effective, which itself may create a myriad of workflow challenges. In addition, newer lymphoscintigraphy agents, specifically 99mTc-tilmanocept, have shown no difference from 99mTc-sulfur colloid in experienced pain (5), demonstrating the stubbornness of this unmet need among the breast cancer population.

Vapocoolants have been previously investigated in a myriad of applications, with the physiology of cryoanalgesia likely related to decreased speed of nerve conduction, decreased release of substances that produce local pain, possible interference of gate control mechanisms, decreased edema related to vasoconstriction, and even possible central nervous system effects related to endorphin release (1,6). Percutaneous probe-based cryoanalgesia has also been investigated in a myriad of situations, generally with regard to peripheral nerve pain (7,8). Although some studies previously have suggested that vapocoolants may not contaminate sterile fields (9,10), it was only recently that the Food and Drug Administration cleared a vapocoolant for sterile procedures, which instigated this clinical trial, the specific product being Nüm topical anesthetic spray, created by 623 Medical and distribution by Gilero.

MATERIALS AND METHODS

Twenty-nine consecutive patients at a single subspecialty institution who had a diagnosis of breast cancer gave consent to be enrolled into our registered clinical trial and feasibility study (NCT05744557) and received vapocoolant analgesia as part of their breast lymphoscintigraphy examination. The local institutional review board approved the study, and all subjects gave written informed consent. Procedural details, lymphoscintigraphy results, and questionnaire results (self-reported pain on a scale of 1–10 and a yes/no question asking, “Would you recommend vapocoolant to other patients undergoing breast lymphoscintigraphy?”) were prospectively recorded and subsequently analyzed. The plan was to initially enroll 30 patients, but one patient was registered erroneously because of clerical error and, once recognized, was subsequently moved off trial.

The inclusion criteria included any patient referred for breast lymphoscintigraphy to be performed with the subareolar technique. Patients who requested a peritumoral injection were excluded.

For the subareolar injection, the intended needle tract was sterilized using alcohol swabbing. The radiotracer syringe was then removed from its lead casing just before vapocoolant administration to limit the time between vapocoolant administration and radiotracer injection and, therefore, rewarming. Vapocoolant was then administered to the skin at approximately 0.8–1.6 cm (2–4 in) from the intended needle tract, proceeding from the needle entry point to the area of subareolar radiotracer deposition in a slow undulating manner. If the skin frosted, vapocoolant administration was immediately ceased; otherwise, administration continued until the canister was empty (usually about 5 s).

Immediately on cessation of vapocoolant administration, the lymphoscintigraphy needle was inserted along the peripheral aspect of the vapocooled zone and then was advanced intradermally to the target subareolar region. Once in a satisfactory position, the radiotracer was administered expeditiously to limit the effects of rewarming and then was removed.

Planar anterior posterior and lateral images were obtained sequentially by the technologist until a sentinel lymph node was identified, with the first set of images usually acquired at 1 h after injection. Injections were performed on both same-day-surgery and next-day-surgery patients.

RESULTS

All lymphoscintigraphy examinations were successful, with an ipsilateral lymph node identified in each patient (29/29) (Table 1). The average length of lymphoscintigraphy studies was 2.4 h (median, 1 h; range, 1–4.5 h). No complications were encountered (0/29). All patients recommended vapocoolant for breast scintigraphy (29/29), with an average self-reported pain score of 1.98 (median, 1; range, 1–10). In addition, 37.9% (11/29) experienced no pain at all, with a stated pain score of zero (Table 2).

View this table:
  • View inline
  • View popup
TABLE 1.

Results

View this table:
  • View inline
  • View popup
TABLE 2.

Result Analysis

DISCUSSION

The results of this clinical trial and feasibility study suggest that vapocoolant administration in the setting of breast lymphoscintigraphy is indeed feasible and, most importantly, does not affect the actual lymphoscintigraphy study, thus likely satisfying the first rule of clinical medicine: “Do no harm.” Furthermore, none of the patients seemed to have any strong aversion to vapocoolant administration, with all trial participants recommending vapocoolant administration for breast lymphoscintigraphy, which was a local concern before this feasibility study.

The effects of topical vapocoolants appear to involve predominantly the cutaneous and superficial subcutaneous tissues, making vapocoolants ideal for use in lymphoscintigraphy. Previous trials investigating vapocoolant use for puncture of an artery, generally considered a deeper structure, did not demonstrate any significant benefit (11).

Previous studies have characterized temperature thresholds with regard to cryoanalgesia, with the suggestion that analgesia be initiated at 13.6°C, with 2-point discrimination being compromised at 4°C and complete numbness occurring at 2°C. Such findings suggest that procedures should be performed expediently on vapocoolant administration and that the analgesic effect is likely quick to resolve (12,13). Such is why, as best as possible, lymphoscintigraphy was performed immediately after vapocoolant administration—to avoid confounding secondary to rewarming of the skin—and the lymphoscintigraphy dose was removed from its lead container just before vapocoolant administration to limit the intervening time. Moving forward, we plan to investigate several techniques that may optimize the effect of vapocoolant administration, including possible localization of the needle (specifically, piercing the skin and then placing the needle tip at the intended point of injection) before vapocoolant administration. Splitting the vapocoolant administration may also warrant exploration. We also plan to move forward with case-control trials in both breast cancer and malignant melanoma scintigraphy to better objectively elucidate the vapocoolant benefits.

Overall, our preliminary results suggest a rather low pain score of under 2 in a procedure that is otherwise considered exquisitely painful. We encourage other sites to conduct their own feasibility studies to help breast cancer patients experience a less painful treatment experience.

CONCLUSION

Vapocoolant analgesia for breast scintigraphy is feasible, does not appear to compromise lymphoscintigraphy, is recommended by patients, and appears to be associated with overall low pain scores.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Is vapocoolant administration feasible in the setting of breast lymphoscintigraphy?

PERTINENT FINDINGS: Vapocoolant administration in the setting of breast lymphoscintigraphy does not appear to be associated with any complications, does not appear to affect lymphoscintigraphy success, and appears to be associated with low patient-reported pain scores.

IMPLICATIONS FOR PATIENT CARE: Vapocoolant administration may render breast lymphoscintigraphy more comfortable for patients.

Footnotes

  • Published online Nov. 14, 2023.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Ernst E,
    2. Fialka V
    . Ice freezes pain? A review of the clinical effectiveness of analgesic cold therapy. J Pain Symptom Manage. 1994;9:56–59.
    OpenUrlCrossRefPubMedGoogle Scholar
  2. 2.↵
    1. Virk J,
    2. Smock B,
    3. Nadeem M,
    4. et al
    . The use of periareolar topical lidocaine jelly after needle localization may reduce pain of subsequent lymphoscintigraphy. Cureus. 2020;12:e7861.
    OpenUrlGoogle Scholar
  3. 3.↵
    1. Hawkins AS,
    2. Yoo DC,
    3. Movson JS,
    4. et al
    . Administration of subcutaneous buffered lidocaine prior to breast lymphoscintigraphy reduces pain without decreasing lymph node visualization. J Nucl Med Technol. 2014;42:260–264.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  4. 4.↵
    1. Holliday RM,
    2. Jain MK,
    3. Accurso JM,
    4. et al
    . Buffering the suffering of breast lymphoscintigraphy. J Nucl Med Technol. 2020;48:51–53.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  5. 5.↵
    1. Murphy BL,
    2. Woodwick AR,
    3. Murphy KM,
    4. et al
    . 99mTc-tilmanocept versus 99mTc sulfur colloid in lymphoscintigraphy: sentinel lymph node identification and patient reported pain. J Nucl Med Technol. 2019;47:300–304.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  6. 6.↵
    1. Samborski W,
    2. Stratz T,
    3. Sobieska M,
    4. et al
    . Intraindividual comparison of whole body cold therapy and warm treatment with hot packs in generalized tendomyopathy [in German]. Z Rheumatol. 1992;51:25–30.
    OpenUrlPubMedGoogle Scholar
  7. 7.↵
    1. Yasin J,
    2. Thimmappa N,
    3. Kaifi JT,
    4. et al
    . CT-guided cryoablation for post-thoracotomy pain syndrome: a retrospective analysis. Diagn Interv Radiol. 2020;26:53–57.
    OpenUrlPubMedGoogle Scholar
  8. 8.↵
    1. Filippiadis D,
    2. Efthymiou E,
    3. Tsochatzis A,
    4. et al
    . Percutaneous cryoanalgesia for pain palliation: current status and future trends. Diagn Interv Imaging. 2021;102:273–278.
    OpenUrlGoogle Scholar
  9. 9.↵
    1. Evans JG,
    2. Taylor DM,
    3. Hurren F,
    4. et al
    . Effects of vapocoolant spray on skin sterility prior to intravenous cannulation. J Hosp Infect. 2015;90:333–337.
    OpenUrlGoogle Scholar
  10. 10.↵
    1. Schleicher WF,
    2. Richards BG,
    3. Huettner F,
    4. et al
    . Skin sterility after application of a vapocoolant spray. Dermatol Surg. 2014;40:1103–1107.
    OpenUrlGoogle Scholar
  11. 11.↵
    1. Farahmand S,
    2. Mirfazaelian H,
    3. Sedaghat M,
    4. et al
    . Vapocoolant spray effectiveness on arterial puncture pain: a randomized controlled clinical trial. Acta Med Iran. 2017;55:87–91.
    OpenUrlGoogle Scholar
  12. 12.↵
    1. Provins KA,
    2. Morton R
    . Tactile discrimination and skin temperature. J Appl Physiol. 1960;15:155–160.
    OpenUrlPubMedGoogle Scholar
  13. 13.↵
    1. Bugaj R
    . The cooling, analgesic, and rewarming effects of ice massage on localized skin. Phys Ther. 1975;55:11–19.
    OpenUrlPubMedGoogle Scholar
  • Received for publication June 19, 2023.
  • Revision received October 26, 2023.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 52 (2)
Journal of Nuclear Medicine Technology
Vol. 52, Issue 2
June 1, 2024
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial
Sanjit O. Tewari, Nina Tamirisa, Guofan Xu, Yang Lu
Journal of Nuclear Medicine Technology Jun 2024, 52 (2) 104-106; DOI: 10.2967/jnmt.123.266143
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Comment Regarding "Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial"
  • Lets Meet in 'The 6 for SNMMIs Annual Meeting
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

  • Comment Regarding “Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial”
  • Lymphoscintigraphy: Breast and Melanoma
  • PET/MRI Assessment of Acute Cardiac Inflammation 1 Month After Left-Sided Breast Cancer Radiation Therapy
  • Investigating a Technologist-Driven Injection Technique in Lymphoscintigraphy at a Single Rural Center: A Retrospective Audit
  • Lymphoscintigraphic Mapping in Melanoma and Breast Cancer
See more

Keywords

  • breast
  • oncology
  • breast cancer
  • lymphoscintigraphy
  • vapocoolant
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial
Sanjit O. Tewari, Nina Tamirisa, Guofan Xu, Yang Lu
Journal of Nuclear Medicine Technology Jun 2024, 52 (2) 104-106; DOI: 10.2967/jnmt.123.266143

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.