Article Figures & Data
Tables
Radiopharmaceutical Radiation dose to the breast (mGy/MBq [rad/mCi]) Organ receiving largest radiation dose (mGy/MBq [rad/mCi]) Effective dose (mSv/MBq [rem/mCi]) 99mTc-sestamibi, resting subject 0.0038 (0.014) Gallbladder: 0.039 (0.14) 0.0071* to 0.0090 (0.026–0.033) 99mTc-tetrofosmin, resting subject 0.0020 (0.0074) Gallbladder: 0.036 (0.13) 0.0062* to 0.0080 (0.023–0.030) Unless otherwise noted, data are from ICRP Publication 128 (55).
* An updated estimate of effective dose specific to female subjects was provided in Andersson et al. (56).
Fetal dose Stage of gestation mGy/MBq rad/mCi Early 0.015 0.055 3 mo 0.012 0.044 6 mo 0.0084 0.031 9 mo 0.0054 0.020 ↵99mTc-sestamibi dose estimates to fetus are from Russell et al. (57). No information about possible placental crossover of this compound was available for use in estimating fetal doses.