Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleBrief Communication

In Patients We Trust: Reliability of Self-Reported Weight and Height in Nuclear Medicine Patients

Katrin Sabine Blum, Nadine Büsch, Thomas Beyer, Ivo Rausch and Lutz Stefan Freudenberg
Journal of Nuclear Medicine Technology June 2019, 47 (2) 133-136; DOI: https://doi.org/10.2967/jnmt.118.216317
Katrin Sabine Blum
1ZRN Rheinland, Center for Radiology and Nuclear Medicine, Korschenbroich, Germany
2Department of Diagnostic and Interventional Radiology, University Dusseldorf Medical Faculty, Dusseldorf, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nadine Büsch
1ZRN Rheinland, Center for Radiology and Nuclear Medicine, Korschenbroich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Beyer
3QIMP Team, Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ivo Rausch
3QIMP Team, Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lutz Stefan Freudenberg
1ZRN Rheinland, Center for Radiology and Nuclear Medicine, Korschenbroich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    Accuracy of self-reported weight (A) and height (B) compared with measured weight (A) and height (B).

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    Grade of confidence in self-reported height (A) and weight (B) compared with difference in measured values (%).

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    Histograms of differences between BMI (A), BSA (B), and LBM (C) calculated from self-reported and measured values.

Tables

  • Figures
    • View popup
    TABLE 1

    Self-Reported and Measured Values and the Difference Between Them

    ParameterSelf-reported valuesMeasured valuesDifference (%)
    Weight (kg)
     Total (n = 824)78.9 ± 17.7 (37.0–161.5)80.3 ± 18.3 (34.0–161.0)−1.6 ± 3.0 (−18.6 to 14.7)
     Female (n = 490)73.0 ± 16.9 (37.0–135.0)74.3 ± 17.5 (34.0–135.0)−1.6 ± 2.9 (−15.4 to 14.7)
     Male (n = 334)87.5 ± 15.2 (54.5–161.5)88.9 ± 15.9 (56.0–161.0)−1.5 ± 3.3 (−18.6 to 4.5)
    Height (cm)
     Total (n = 713)170.5 ± 9.4 (146.0–196.0)170.1 ± 9.5 (146.0–196.0)0.2 ± 1.2 (−5.0 to 7.5)
     Female (n = 413)164.9 ± 6.2 (146.0–186.0)164.5 ± 6.5 (146.0–186.0)0.2 ± 1.1 (−5.0 to 7.5)
     Male (n = 300)178.1 ± 7.2 (158.0–196.0)177.7 ± 7.5 (156.0–196.0)0.2 ± 1.2 (−2.3 to 7.5)
    BMI (kg/m2) (n = 713)27.1 ± 5.4 (14.5–50.7)27.6 ± 5.7 (14.8–52.1)−1.9 ± 3.7 (−22.0 to 13.2)
    BSA (m2) (n = 713)1.9 ± 0.2 (1.3–2.7)1.9 ± 0.2 (1.2–2.7)−0.5 ± 1.6 (−9.1 to 8.3)
    LBM (kg) (n = 713)54.6 ± 10.2 (31.7–82.7)54.9 ± 10.4 (28.9–84.0)−0.3 ± 2.2 (−11.2 to 12.3)
    • Data are mean ± SD, followed by range in parentheses.

    • View popup
    TABLE 2

    Number of Self-Reported and Measured Values Differing by at Least 5% and 10%

    Parameter≥5% difference≥10% difference
    Weight11% (91/824)2% (18/824)
    Height1% (5/713)0% (0/713)
    BMI19% (132/713)4% (25/713)
    BSA1% (10/713)0% (0/713)
    LBM4% (28/713)<1% (2/713)
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 47 (2)
Journal of Nuclear Medicine Technology
Vol. 47, Issue 2
June 1, 2019
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
In Patients We Trust: Reliability of Self-Reported Weight and Height in Nuclear Medicine Patients
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
In Patients We Trust: Reliability of Self-Reported Weight and Height in Nuclear Medicine Patients
Katrin Sabine Blum, Nadine Büsch, Thomas Beyer, Ivo Rausch, Lutz Stefan Freudenberg
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 133-136; DOI: 10.2967/jnmt.118.216317

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
In Patients We Trust: Reliability of Self-Reported Weight and Height in Nuclear Medicine Patients
Katrin Sabine Blum, Nadine Büsch, Thomas Beyer, Ivo Rausch, Lutz Stefan Freudenberg
Journal of Nuclear Medicine Technology Jun 2019, 47 (2) 133-136; DOI: 10.2967/jnmt.118.216317
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Self-Reported Weight and Height in Nuclear Medicine Patients: A Common Mistake Confusing Reliability and Accuracy
  • Google Scholar

More in this TOC Section

  • Can an Abnormal Gastric Emptying Study Be Normal?
  • Patient Motion During Cardiac PET Imaging
  • Logistics of Adopting 177Lu-Vipivotide Tetraxetan Therapy in a Community-Based Hospital Setting
Show more Brief Communication

Similar Articles

Keywords

  • self-reported weight and height
  • nuclear medicine imaging and therapy
  • BMI
  • BSA
  • LBM
SNMMI