Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleRADIOPHARMACY

Comparison of FASTlab 18F-FDG Production Using Phosphate and Citrate Buffer Cassettes

James Z. Long, Mark S. Jacobson and Joseph C. Hung
Journal of Nuclear Medicine Technology March 2013, 41 (1) 32-34; DOI: https://doi.org/10.2967/jnmt.112.112649
James Z. Long
Department of Radiology, Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mark S. Jacobson
Department of Radiology, Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joseph C. Hung
Department of Radiology, Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Tables

    • View popup
    TABLE 1

    Relationship Between RCY, RCP, RSC, and pH of Each Cassette

    CassetteAverage corrected RCY (%)Average uncorrected RCY (%)Average RCP (%)Average pHAverage EtOH (%)Average MeCN (%)
    Phosphate cassette82.9 ± 17.457.5 ± 16.799.4 ± 0.195.9 ± 0.10.08 ± 0.02<0.01
    Citrate cassette79.2 ± 5.058.8 ± 6.099.0 ± 1.15.3 ± 0.20.20 ± 0.07<0.01
    Percentage difference4.362.160.539.6235Not applicable
    P0.110.320.0212.6 × 10−192.96 × 10−15Not applicable
    • View popup
    TABLE 2

    Radioactive Concentration of Each Cassette

    Average radioactive concentrationRange of radioactive concentration
    CassettemCi/mLGBq/mLmCi/mLGBq/mL
    Phosphate cassette*33912.567–4622.48–17
    Citrate cassette†1345.061–2382.26–8.8
    • ↵* 15 mL, final volume.

    • ↵† 29 mL, final volume.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 41 (1)
Journal of Nuclear Medicine Technology
Vol. 41, Issue 1
March 1, 2013
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of FASTlab 18F-FDG Production Using Phosphate and Citrate Buffer Cassettes
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Comparison of FASTlab 18F-FDG Production Using Phosphate and Citrate Buffer Cassettes
James Z. Long, Mark S. Jacobson, Joseph C. Hung
Journal of Nuclear Medicine Technology Mar 2013, 41 (1) 32-34; DOI: 10.2967/jnmt.112.112649

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparison of FASTlab 18F-FDG Production Using Phosphate and Citrate Buffer Cassettes
James Z. Long, Mark S. Jacobson, Joseph C. Hung
Journal of Nuclear Medicine Technology Mar 2013, 41 (1) 32-34; DOI: 10.2967/jnmt.112.112649
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Miniaturized Radiochemical Purity Testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-Tetrofosmin
  • Changes in Patterns of 99mTc-Macroaggregated Albumin Use Between 2000 and 2015
  • Absorbed Radiation Doses to Staff After Implementation of a Radiopharmacy Clean Room
Show more Radiopharmacy

Similar Articles

Keywords

  • PET radiochemistry
  • 18F-FDG
  • radiopharmacy
  • quality control
SNMMI

© 2025 SNMMI

Powered by HighWire