Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Abstract

The influence of flood source placement on radiation exposure during quality control testing.

M J Rudin and W H Johnson
Journal of Nuclear Medicine Technology June 2000, 28 (2) 88-93;
M J Rudin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W H Johnson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

This study examined the photon energy distribution and exposure rate from a 250-MBq 57Co flood source during quality control (QC) procedures as a function of source placement and measurement location. The optimum placement of the source to reduce the radiation dose to the nuclear medicine technologist during QC checks was determined.

Measurements of exposure rate were made inside and outside a camera room with the source positioned either above or below the camera head. The energy distribution of the photon field was examined at the same locations using a high-resolution gamma-ray spectrometer. Additional measures of exposure rate were made with the source at various distances from the camera face.

The lowest exposure rates occurred when the source was lying directly on the face of the camera head. The exposure rates at locations inside the camera room increased by a factor of 4.3 +/- 3.0 when the source was placed on an imaging table below the camera head. This increase can be attributed to decreased shielding provided by the camera head.

A large portion of the radiation dose received by technologists during QC checks is due to scattered radiation and x-rays produced by gamma-ray interactions within the camera. This dose can be reduced significantly if QC checks are performed with the flood source lying directly on the inverted gamma camera head rather than placing the flood source on an imaging table under the gamma camera.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology
Vol. 28, Issue 2
June 1, 2000
  • Table of Contents
  • Index by author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The influence of flood source placement on radiation exposure during quality control testing.
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
The influence of flood source placement on radiation exposure during quality control testing.
M J Rudin, W H Johnson
Journal of Nuclear Medicine Technology Jun 2000, 28 (2) 88-93;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The influence of flood source placement on radiation exposure during quality control testing.
M J Rudin, W H Johnson
Journal of Nuclear Medicine Technology Jun 2000, 28 (2) 88-93;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire