Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherRADIATION SAFETY

Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET

Benjamin Guillet, Pierre Quentin, Serge Waultier, Marc Bourrelly, Pascale Pisano and Olivier Mundler
Journal of Nuclear Medicine Technology September 2005, 33 (3) 175-179;
Benjamin Guillet
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierre Quentin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Serge Waultier
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marc Bourrelly
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pascale Pisano
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Olivier Mundler
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Objective: The use of 18F-FDG for clinical PET studies increases technologist radiation dose exposure because of the higher γ-radiation energy of this isotope than of other conventional medical γ-radiation–emitting isotopes. Therefore, 18F-FDG imaging necessitates stronger radiation protection requirements. The aims of this study were to assess technologist whole-body and extremity exposure in our PET department and to evaluate the efficiency of our radiation protection devices (homemade syringe drawing device, semiautomated injector, and video tracking of patients).

Methods: Radiation dose assessment was performed for monodose as well as for multidose 18F-FDG packaging with both LiF thermoluminescence dosimeters (TLD) and electronic personal dosimeters (ED) during 5 successive 18F-FDG PET steps (from syringe filling to patient departure).

Results: The mean ± SD total effective doses received by technologists (n = 50) during all of the working steps were 3.24 ± 2.1 and 3.01 ± 1.4 μSv, respectively, as measured with ED and TLD (345 ± 84 MBq injected). These values were confirmed by daily TLD technologist whole-body dose measurements (2.98 ± 1.8 μSv; 294 ± 78 MBq injected; n = 48). Finger irradiation doses during preparation of single 18F-FDG syringes were 204.9 ± 24 and 198.4 ± 23 μSv with multidose vials (345 ± 93 MBq injected) and 127.3 ± 76 and 55.9 ± 47 μSv with monodose vials (302 ± 43 MBq injected) for the right hand and the left hand, respectively. The protection afforded by the semiautomated injector, estimated as the ratio of the doses received by TLD placed on the syringe shield and on the external face of the injector, was near 2,000.

Conclusion: These results showed that technologist radiation doses in our PET department were lower than those reported in the literature. This finding may be explained by the use of a homemade syringe drawing device, a semiautomated injector, and patient video tracking, allowing a shorter duration of contact between the technologist and the patient. Extrapolation of these results to an annual dose (4 patients per day per technologist) revealed that the annual extrapolated exposure values remained under the authorized limits for workers classified to work in a radioactivity-controlled area.

  • radiation dose exposure
  • radiation protection devices
  • dosimetry
  • 18F-FDG PET

The setup of a PET scanner in a nuclear medicine department (PET/CT scanner) for 18F-FDG oncology imaging raised the issue of radiation dose exposure of technologists undertaking the preparation and administration of this radiopharmaceutical. Indeed, the higher γ-radiation energy of positron-emitting isotopes (511 keV) means that staff members could receive a higher whole-body dose than those working only with conventional nuclear medicine tracers. To date, however, few data have been published on technologist radiation doses received during work in dedicated PET departments (1,2). These studies measured whole-body doses received during 1 workday in a PET center using various positron-emitting isotopes (14.4 μSv) (2) or dose rates at various distances from patients injected with 370 MBq of 18F-FDG (the median exposure at 2 m from the patient at 1 h after injection was 2 μSv/h) (3). Some other studies aimed to evaluate hand doses received during 18F-FDG PET scanning and reported values of 710 μSv per technologist (4). All of these results are difficult to compare because radiation protection means are very dissimilar and because of differences in 18F-FDG packaging among suppliers (unit-dose [monodose] or multidose vials). Moreover, the dose measurements were recorded with electronic personal dosimeters (ED) worn at waist and wrist levels and did not provide information on the doses received by the fingers or with thermoluminescence dosimeters (TLD) worn around the second finger. Ring TLD have the disadvantage of a time lag measurement of the dose once per month because they cannot be changed at every step of 18F-FDG manipulation.

The aims of this study were, first, to inform technologists working with 18F-FDG about their whole-body and finger radiation doses and to compare our results with the maximum admissible doses prescribed by European Directive EURATOM 96/29 05/13/1996; second, to validate our radiation protection devices (especially our homemade syringe drawing device and a commercially available semiautomated injector); and third, to measure radiation doses corresponding to different kinds of 18F-FDG packaging.

MATERIALS AND METHODS

The Timone Hospital Nuclear Department PET/CT scanner is a dedicated Discovery ST scanner (GE Healthcare). Three technologists are assigned to cover a workday from 8:00 am to 6:00 pm. On an average day, the PET/CT scanner will image 10–13 patients. The study was conducted over a period of 6 mo, and measurements were recorded from the first PET examination of the day (n = 80), which corresponds to the highest multidose vial activity. All of the technologists were right handed.

18F-FDG Packaging

18F-FDG is supplied either in monodose vials (Cis-Bio Schering) or in multidose vials (4 doses; IBA) in lead containers with radioactivity per vial ranging from 450 MBq to 4 GBq.

18F-FDG Manipulation and Protection Devices

The 18F-FDG PET procedure was divided into 5 working steps. The first step is receipt of the 18F-FDG containers. The radiotracer is handled within a dedicated “hot” laboratory, being drawn up behind a large bench-mounted 60-mm-thick lead shield that has a 55-mm lead-equivalent glass insert (Lemer Pax). The dramatic high activity of 18F-FDG multidose vials led us to develop a homemade drawing device to allow syringe filling without direct contact with the vial, which remains in the hole of the dosimeter (Figs. 1A–1C). The second step is measurement of the total activity of the vial and the drawing up of the 18F-FDG dose (5 MBq/kg) in a syringe placed inside a 10-mm tungsten syringe shield (Lemer Pax). The third step is placement of the syringe in its shield into a semiautomated injector surrounded by a 30-mm-thick lead shield to avoid manual handling of the syringe. The fourth step is infusion of the 18F-FDG dose into the patient through a catheter that is withdrawn 40 min later. The last step includes the time spent in collecting the patient 1 h after the tracer infusion, escorting the patient to the PET room, positioning within the camera and, finally, after image acquisition, escorting the patient out of the department.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Schematic representation of our homemade drawing device. (A) Global view of device. (B) Positioning of 18F-FDG vial in hole of dosimeter. (C) Syringe filling. (D) Shielded semiautomated injector.

The technologists spend most of the scanning time in the control room, with a direct view of the patient through lead glass and a video link. The time spent in each step, the 18F-FDG activity injected, and the identified technical incidents are systematically monitored.

Dosimetry

18F-FDG Multidose Vials.

ED (Siemens EPD mk2.3) placed in the upper left pocket of technologist overalls allowed measurement of the whole-body individual dose at the end of each step of the 18F-FDG and patient manipulations. These dosimeters were calibrated twice each year by the Commissariat à l’Energie Atomique. The whole-body dose also was determined with 3 cylindric LiF TLD (diameter, 4.5 mm; thickness, 0.8 mm; GR200A; Société Fimel) placed in the upper left pocket of overalls worn by 3 agents during an entire PET center workday. The dose received by the irradiated TLD was determined with a PCL3 thermoluminescence reader (Société Fimel) according to manufacturer instructions. Measurements were recorded from 50 preparations. The values obtained were divided by the number of patients undergoing PET scans (mean of 12 patients per day) to confirm more accurately the whole-body dose received per patient. The dose reported for each pack of 3 TLD was the mean of the 3 measurements.

The dose received by the fingers during the first 3 steps of 18F-FDG manipulation was assessed with 2 of the TLD placed on the inside of the second finger of each hand. The TLD were selected and calibrated after exposure to 160 mGy of 60Co irradiation (1000 IEC 60Co generator; Theratron). Measurements were recorded from 50 preparations. The dose reported for each pair of TLD was the mean of the 2 measurements.

18F-FDG Monodose Vials.

Because the difference in exposure related to the manipulation of monodose or multidose vials of 18F-FDG is related only to steps 1 and 2, we compared the values obtained for whole-body irradiation and finger irradiation during these first 2 steps with monodose or multidose vials of 18F-FDG. Measurements were recorded from 30 preparations.

To estimate the protection afforded by the semiautomated injector, 3 TLD were placed directly on the syringe shield, and 3 other TLD were placed on the external face of the injector. Ten pairs of TLD were used for this determination.

Statistical Analysis

All values are reported as mean ± SD. The Mann–Whitney test was performed to statistically compare values obtained with TLD for whole-body and finger exposures during the first 2 steps with each 18F-FDG package and whole-body doses obtained with TLD and ED. A P value of <0.05 was considered significant.

RESULTS

The effective doses measured during steps 1 and 2 with TLD and ED were negligible (step 1, ED: 0.29 ± 0.4 μSv; step 2, ED: 0.10 ± 0.1 μSv); therefore, Table 1 shows only the mean ± SD for whole-body doses during steps 3, 4, and 5 of manipulation of multidose vials of 18F-FDG, as recorded by ED and TLD worn in the upper left pocket of the overalls (n = 50). The mean ± SD total effective doses received by technologists during all of the steps of 1 18F-FDG dose preparation were 3.24 ± 2.1 and 3.01 ± 1.4 μSv for ED and TLD, respectively (345 ± 84 MBq injected). These 2 groups of values (ED and TLD) did not differ significantly.

View this table:
  • View inline
  • View popup
TABLE 1

Mean ± SD (n = 50) Whole-Body Doses During Steps 3, 4, and 5, as Estimated by ED and TLD Worn in Upper Left Pocket of Overalls

Table 2 shows the mean ± SD for finger irradiation during the first 3 steps of manipulation of 18F-FDG multidose vials (n = 50). The mean ± SD total doses received at the finger level were 231.9 ± 36 and 206.3 ± 32 μSv for the right hand and the left hand, respectively. The mean ± SD total doses received at the finger level during the first 2 steps of 1 18F-FDG dose preparation were 204.9 ± 24 and 198.4 ± 23 μSv, respectively, for the right hand and the left hand, respectively (mean ± SD vial activity: 3,240 ± 1,102 MBq; mean ± SD syringe activity: 345 ± 93 MBq).

View this table:
  • View inline
  • View popup
TABLE 2

Mean ± SD (n = 50) Finger Irradiation During First 3 Steps of Manipulation of 18F-FDG Multidose Vials

Table 3 shows the mean ± SD finger doses during the first 2 steps of manipulation of monodose vials of 18F-FDG (n = 30). The mean ± SD total doses received at the finger level for 1 18F-FDG dose preparation were 127.3 ± 76 and 55.9 ± 47 μSv for the right hand and the left hand, respectively (mean ± SD vial activity: 405 ± 22 MBq; mean ± SD syringe activity: 302 ± 43 MBq).

View this table:
  • View inline
  • View popup
TABLE 3

Mean ± SD (n = 30) Finger Doses During First 2 Steps of Manipulation of 18F-FDG Monodose Vials

The mean ± SD irradiation rates for TLD positioned either directly on the syringe shield or on the external face of the injector are shown in Table 4 (n = 10). The mean ± SD ratio of the dose received by the syringe TLD and the dose received by the injector TLD was 1,852 ± 860, a value that corresponds to nearly complete protection.

View this table:
  • View inline
  • View popup
TABLE 4

Mean ± SD (n = 10) Dose Rates Measured by TLD Positioned Either on Syringe Shield Inside Injector or on External Face of Injector

The mean ± SD dose received by TLD worn in the upper left pocket of the overalls by 3 agents during an entire PET center workday, determined in relation to the number of patients undergoing PET scans (n = 48), was 2.98 ± 1.8 μSv. The mean ± SD activity injected into the patients was 294 ± 78 MBq.

Technical problems occurring throughout the 18F-FDG manipulations dramatically increased the doses received by the technologists and are shown in Table 5.

View this table:
  • View inline
  • View popup
TABLE 5

Whole-Body and Finger Doses Related to Technical Problems Occurring Throughout 18F-FDG Manipulation

DISCUSSION

Numerous studies (5–11) have reported the effective doses received by nuclear medicine technologists, but few have considered specifically positron-emitting tracers. The results presented in our study show that, for 12 mo in succession, the radiation exposure at the whole-body and finger levels of technologists during 18F-FDG manipulation in our PET center is dramatically lower than the maximum values allowed in European Directive EURATOM 96/29 05/13/1996 (whole-body effective dose: <20 mSv/y; equivalent finger dose: 500 mSv/y).

During step 1, the doses received by the left hand were obviously significantly higher when multidose vials were used than when monodose vials were used (135.2 ± 192 μSv vs. 14.9 ± 20 μSv) because of close contact with the 18F-FDG vial, whose activity is near 3.5 GBq at the time of supplying.

During step 2, right-hand exposure was significantly higher than left-hand exposure, as the right hand was close to the tubing of the drawing device filled with 18F-FDG (Fig. 1C). This discrepancy was more evident when multidose vials were used than when monodose vials were used (211.3 ± 180 μSv vs. 43.4 ± 39 μSv) because of the higher volumic activity (multidose: 555 MBq/mL; monodose: 250 MBq/mL). Shielding of the tubing has been considered, but it would impede visual control of syringe filling.

However, the higher doses received with multidose vials than with monodose vials must be balanced for 2 reasons: first, the mean time spent during step 1 (177 ± 111 and 112.7 ± 41 s for multidose and monodose vials, respectively) must be repeated for each patient with monodose vials, whereas with multidose vials, the procedures are performed every 4 patients; second, the total activity of the multidose vials decreases according to the 18F-FDG half-life.

It is difficult to strictly compare PET centers because of variability in protocols, acquisition times, injected activity, and radiation protection devices used, but we can nevertheless compare the effective dose measured during the entire PET procedure in our study with those reported in the literature. Published data on the radiation exposure of technologists during 18F-FDG PET scanning are very sparse. Chiesa et al. (1) and Benatar et al. (2) reported similar technologist effective doses per whole-body 18F-FDG PET scanning of 5.9 μSv (500 MBq per patient) and 5.5 μSv (14.4 μSv/d; 320 MBq per patient; 2–3 patients per day), respectively. However, Linemann et al. (4) in Germany reported a mean total personal dose of at least 10 μSv per technologist.

The technologist exposure doses reported above are higher than our ED or TLD measured doses. In the study of Chiesa et al. (1), the higher injected activity could partly explain this difference (500 MBq vs. 345 MBq). Moreover, less close contact with the radioactive source in the present study than in the study of Benatar et al. (2) (9.2 min per technologist per patient vs. 13.9 min per technologist per patient), the use of a semiautomated injector, and the video and audio tracking of the injected patients could be involved in the lower radiation exposure in the present study.

Because the measured values were subdivided into separate contributions from each phase of the manipulation of 18F-FDG, it is possible to compare step by step the whole-body and finger doses measured with the very sparse published data.

Concerning the effective dose, as a consequence of the maximum shielding of the hot cell, the first 2 steps of 18F-FDG manipulation led to negligible values comparable to ours (<1 μSv) (4). In contrast, steps 3, 4, and 5 induced greater radiation exposure, which is highly dependent on the radiation protection means used, especially a shielded automated injector or a lead screen for injection and a video link to avoid close contact with the injected patients. None of the published data evaluated radiation exposure during the transfer of the syringe from the hot cell to the patient. According to the work of Linemann et al. (4), the effective dose measured during the injection step led to about 3 μSv per injection, a value that is higher than the values measured by our ED (1.08 ± 1.6 μSv) or TLD (0.81 ± 1.0 μSv) during this step. It is worth noting that these authors did not describe the protection devices used for injection; the discrepancies in effective doses measured are probably attributable to the use in our study of the shielded semiautomated injector, which afforded nearly complete protection. In our PET center, where patients are located in rooms without direct communication with the hot laboratory, this automated injector is very useful for transferring the dose from the hot laboratory to the injection rooms.

The only published study focusing on the dose received by the hands, estimated by TLD, was that of Linemann et al. (4), who reported a mean finger exposure of 710 μSv during syringe preparation from 18F-FDG multidose vials. Under these conditions, if we sum the right and left hand doses from our first 3 steps, whatever the 18F-FDG packaging used, the mean values obtained are at least 3 times lower (mean ± SD finger dose from steps 1, 2, and 3 for multidose vials: right hand = 231.9 ± 36 μSv and left hand = 206.3 ± 32 μSv; mean ± SD finger dose from steps 1, 2, and 3 for monodose vials: right hand = 157.3 ± 67 μSv and left hand = 78.2 ± 43 μSv). These differences probably can be explained by the use of our homemade drawing device, which avoids close contact between the technologist’s hands and the 18F-FDG vial and which appears to be more effective than the grip used by Linemann et al. (4). Moreover, the use of the shielded semiautomated injector, which avoids syringe handling during the injection, also may contribute to the reduction in hand exposure.

In parallel, we identified some technical problems (Table 5). The first problem occurred during syringe filling (step 2) and was attributable to syringe disconnection from its shield protection, which led to a longer dose preparation time and to higher finger doses. Several other problems led to an increase in the duration of the dose transfer from the hot cell to the semiautomated injector. These problems included expelling air from the syringe, handling the syringe near the technologist’s chest, or difficulties with the syringe interlocking with the semiautomated injector. Moreover, the semiautomated injector got jammed once and therefore caused a longer duration of the injection and an increase in the TLD whole-body dose. One case of a noncompliant patient also occurred, making it necessary to spend more time on positioning and therefore causing an increase in the TLD whole-body dose.

CONCLUSION

It can be concluded from this study that, in our PET center, whatever the 18F-FDG packaging supplied, the use of our homemade drawing device in association with a shielded semiautomated injector and video tracking of patients led to lower technologist radiation exposure at the whole-body and finger levels than the published values. The use of 18F-FDG multidose vials obviously led to higher finger exposure during receipt of the 18F-FDG containers and syringe filling, but this exposure was associated with packaging containing 4 18F-FDG doses and so required only 1 receipt step and drawing device installation every 4 patients. Moreover, for 12 mo in succession and for technologists scanning 4 patients per day, the doses measured with either monodose or multidose vials were always lower than the maximum acceptable values reported in European Directive EURATOM 96/29 05/13/1996, even with the technical problems encountered during 18F-FDG manipulation.

Footnotes

  • For correspondence or reprints contact: Pascale Pisano, PhD, Unité de Radiopharmacie, Service Central de Médecine Nucléaire, CHU Timone, 254 Rue Saint-Pierre, 13005 Marseille, France.

    E-mail: ppisano{at}mail.ap-hm.fr

REFERENCES

  1. ↵
    Chiesa C, De Sanctis V, Crippa F, et al. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med. 1997;24:1380–1389.
    OpenUrlCrossRefPubMed
  2. ↵
    Benatar NA, Cronin BF, O’Doherty MJ. Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas. Eur J Nucl Med. 2000;27:583–589.
    OpenUrlCrossRefPubMed
  3. ↵
    White S, Binns D, Johnston VV, et al. Occupational exposure in nuclear medicine and PET. Clin Positron Imaging. 2000;3:127–129.
    OpenUrlCrossRefPubMed
  4. ↵
    Linemann H, Will E, Beuthien-Baumann B. Investigations of radiation exposure of the medical personnel during F-18-FDG PET studies [in German]. Nuklearmedizin. 2000;39:77–81.
    OpenUrlPubMed
  5. ↵
    Clarke EA, Thomson WH, Notghi A, Harding LK. Radiation doses from nuclear medicine patients to an imaging technologist: relation to ICRP recommendations for pregnant workers. Nucl Med Commun. 1992;13:795–798.
    OpenUrlCrossRefPubMed
  6. Clarke EA, Notghi A, Harding LK. Are MIBI/tetrofosmin heart studies a potential radiation hazard to technologists? Nucl Med Commun. 1997;18:574–577.
    OpenUrlPubMed
  7. Culver CM, Dworkin HJ. Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: technetium-99m-sestamibi versus thallium-201. J Nucl Med. 1993;34:1210–1213.
    OpenUrlAbstract/FREE Full Text
  8. Harbottle EA, Parker RP, Davis R. Radiation doses to staff in a department of nuclear medicine. Br J Radiol. 1976;49:612–617.
    OpenUrlAbstract/FREE Full Text
  9. Harding LK, Mostafa AB, Thomson WH. Staff radiation doses associated with nuclear medicine procedures: a review of some recent measurements. Nucl Med Commun. 1990;11:271–277.
    OpenUrlPubMed
  10. Mountford PJ, O’Doherty MJ. Exposure of critical groups to nuclear medicine patients. Appl Radiat Isot. 1999;50:89–111.
    OpenUrlPubMed
  11. ↵
    Cronin B, Marsden PK, O’Doherty MJ. Are restrictions to behaviour of patients required following fluorine-18 fluorodeoxyglucose positron emission tomographic studies? Eur J Nucl Med. 1999;26:121–128.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 33 (3)
Journal of Nuclear Medicine Technology
Vol. 33, Issue 3
September 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET
Benjamin Guillet, Pierre Quentin, Serge Waultier, Marc Bourrelly, Pascale Pisano, Olivier Mundler
Journal of Nuclear Medicine Technology Sep 2005, 33 (3) 175-179;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET
Benjamin Guillet, Pierre Quentin, Serge Waultier, Marc Bourrelly, Pascale Pisano, Olivier Mundler
Journal of Nuclear Medicine Technology Sep 2005, 33 (3) 175-179;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • The Effects on Technologist Occupational Exposure in PET/CT Departments When Working with Students at Various Levels of Supervision
  • Technologist Approach to Global Dose Optimization
  • Comparison of 3 Devices for Automated Infusion of Positron-Emitting Radiotracers
  • Occupational Radiation Dosimetry Assessment Using an Automated Infusion Device for Positron-Emitting Radiotracers
  • Radiation protection in fixed PET/CT facilities--design and operation
  • Assessment of Patient Exposure to X-Radiation from SPECT/CT Scanners
  • Google Scholar

More in this TOC Section

  • Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand
  • Experiences of Nuclear Medicine Technologists Working in PET/CT Facilities in Gauteng Province, South Africa
  • Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand
Show more RADIATION SAFETY

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire