Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherImaging (JNMT)

Can the Diagnostic Accuracy of Bone Scintigraphy be Maintained with Half the Scanning Time?

Valeria M. Moncayo, Sebastine Chimafor, Elizabeth Lulaj, John A. Malko and Raghuveer K. Halkar
Journal of Nuclear Medicine Technology July 2021, jnmt.121.262163; DOI: https://doi.org/10.2967/jnmt.121.262163
Valeria M. Moncayo
1 Emory University School of Medicine, United States;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastine Chimafor
2 Grady Health System, United States;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elizabeth Lulaj
3 Johns Hopkins Medical Institute / Johns Hopkins University
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John A. Malko
1 Emory University School of Medicine, United States;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Raghuveer K. Halkar
1 Emory University School of Medicine, United States;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

Purpose: We aim to show that the acquisition time of a conventional bone scan can be reduced by one-half without loss of the diagnostic value of the scan. Materials and Methods: Fifty adult patients (37 male and 13 female, mean age 62.5, SD 8.7 years) were enrolled. Patients were injected with 25–30 mCi (925-1110 MBq) 99mTc MDP IV. The Standard Protocol whole body planar images were acquired first [scan speed = 10 cm/min, acquisition time around 20 minutes] and were followed immediately by the Half-Time Protocol whole body planar images [scan speed = 20 cm/min; acquisition time around 10 minutes]. Both images were interpreted by two nuclear medicine physicians. Each reviewer, when reviewing the Standard Protocol images, was “self-blinded” to the result they had obtained when reviewing the Half-Time images, and vice-versa. This self-blinding was accomplished by allowing a minimum of two weeks to elapse between the two interpretations. We used the κ-coefficient to compare the agreement between the Standard-Protocol results and the Half-Time results. Results: There was no difference in clinically significant diagnostic information for Half -Time and Standard Protocol. The diagnostic quality of Half-Time and the Standard Protocol images were not significantly different (0.86 < κ < 1.0). Conclusion: Our data suggest that if we reduce the 99mTc MDP dose by half and keep the acquisition time at its standard value we gain the benefits of reduced dose without loss of diagnostic value of the scan.

  • Bone
  • Radiation Safety
  • SPECT
  • SPECT/CT
  • Half time acquisition
  • Image wisely
  • Tc-99m MDP
  • bone scan
  • bone scintigraphy
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (1)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 1
March 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Can the Diagnostic Accuracy of Bone Scintigraphy be Maintained with Half the Scanning Time?
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Can the Diagnostic Accuracy of Bone Scintigraphy be Maintained with Half the Scanning Time?
Valeria M. Moncayo, Sebastine Chimafor, Elizabeth Lulaj, John A. Malko, Raghuveer K. Halkar
Journal of Nuclear Medicine Technology Jul 2021, jnmt.121.262163; DOI: 10.2967/jnmt.121.262163

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Can the Diagnostic Accuracy of Bone Scintigraphy be Maintained with Half the Scanning Time?
Valeria M. Moncayo, Sebastine Chimafor, Elizabeth Lulaj, John A. Malko, Raghuveer K. Halkar
Journal of Nuclear Medicine Technology Jul 2021, jnmt.121.262163; DOI: 10.2967/jnmt.121.262163
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

Similar Articles

Keywords

  • bone
  • radiation safety
  • SPECT
  • SPECT/CT
  • Half time acquisition
  • Image Wisely
  • Tc-99m MDP
  • bone scan
  • bone scintigraphy
SNMMI

© 2025 SNMMI

Powered by HighWire