Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Imaging

Effect of Time on Liver Clearance of Technetium-99m-Tetrofosmin in Patients with Acute Chest Pain: When Should Imaging Begin?

April Mann, Alan W. Ahlberg, Michael P. White, Dawn M. Cross, Jose Piriz, R. Scott Morris and Gary V. Heller
Journal of Nuclear Medicine Technology September 1998, 26 (3) 186-190;
April Mann
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alan W. Ahlberg
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael P. White
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dawn M. Cross
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jose Piriz
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Scott Morris
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gary V. Heller
Nuclear Cardiology Laboratory, Division of Cardiology, Hartford Hospital, Hartford and the Divisions of Medicine and Nuclear Medicine, University of Connecticut School of Medicine, Farmington, Connecticut
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

Objective: Due to stable myocardial retention and technetium imaging characteristics, 99mTc-tetrofosmin has been considered potentially useful for acute chest pain imaging. Tetrofosmin also has favorable biokinetics with reported rapid liver clearance, 5 min poststress and 30–45 min postrest injection. Since comparable data are not available, the effect of time on liver clearance was evaluated in patients with acute chest pain.

Methods: One hundred six patients received an intravenous injection of 25–30 mCi 99mTc-tetrofosmin to evaluate acute chest pain. SPECT imaging was performed 15–120 min after injection of the tracer. Patient images were grouped according to the time of acquisition after acute injection: 15–30 min, 31–45 min, 46–60 min, 61–90 min and >90 min. Quantitative analysis was performed on a similar anterior projection for each patient consisting of a 6 × 6-pixel region of interest over the myocardium and adjacent liver. Average counts per pixel were determined and a heart/liver (H/Li) ratio was calculated.

Results: The mean H/Li ratio was < 1.0 for patient images acquired 15–45 min after injection, and > 1.0 for patient images acquired after 45 min. The difference was statistically significant (p < 0.05).

Conclusion: Quantitative analysis suggests that the optimal imaging time should be at least 45 min after the injection of 99mTc-tetrofosmin to allow adequate liver clearance before image acquisition of acute chest pain syndromes.

  • technetium-99m-tetrofosmin
  • liver clearance
  • acute chest pain
  • myocardial perfusion imaging
  • ischemic coronary artery disease
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 26 (3)
Journal of Nuclear Medicine Technology
Vol. 26, Issue 3
September 1, 1998
  • Table of Contents
  • Index by author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Effect of Time on Liver Clearance of Technetium-99m-Tetrofosmin in Patients with Acute Chest Pain: When Should Imaging Begin?
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Effect of Time on Liver Clearance of Technetium-99m-Tetrofosmin in Patients with Acute Chest Pain: When Should Imaging Begin?
April Mann, Alan W. Ahlberg, Michael P. White, Dawn M. Cross, Jose Piriz, R. Scott Morris, Gary V. Heller
Journal of Nuclear Medicine Technology Sep 1998, 26 (3) 186-190;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Effect of Time on Liver Clearance of Technetium-99m-Tetrofosmin in Patients with Acute Chest Pain: When Should Imaging Begin?
April Mann, Alan W. Ahlberg, Michael P. White, Dawn M. Cross, Jose Piriz, R. Scott Morris, Gary V. Heller
Journal of Nuclear Medicine Technology Sep 1998, 26 (3) 186-190;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • technetium-99m-tetrofosmin
  • liver clearance
  • acute chest pain
  • myocardial perfusion imaging
  • ischemic coronary artery disease
SNMMI

© 2025 SNMMI

Powered by HighWire