Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Radiopharmacy

Attenuator Calibration Factors Using High and Low Activity Sources

Evelyn R. Merritt
Journal of Nuclear Medicine Technology June 1989, 17 (2) 66-69;
Evelyn R. Merritt
Alton Ochsner Medical Foundation, New Orleans, Louisiana
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

Compliance with Nuclear Regulatory Commission regulations pertaining to the range of activities over which linearity of dose calibrators must be tested requires that the procedure be done with two separate sources (one with high activity; the other with low activity) when the attenuator method of checking dose calibrator linearity is used. This may lead to an incorrect judgment of instrument nonlinearity if the same calibration factors are used for both sources. Disparity in calibration factors as high as 6%-9% has been observed. Possible methods for modifying these calibration factors are identified and include: (1) utilizing different factors for high and low sources; (2) modifying the high activity factors by use of established ratios for use with low activity sources; and (3) averaging a series of factors from high activity sources with those from low activity sources.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 17 (2)
Journal of Nuclear Medicine Technology
Vol. 17, Issue 2
June 1, 1989
  • Table of Contents
  • Index by author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Attenuator Calibration Factors Using High and Low Activity Sources
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Attenuator Calibration Factors Using High and Low Activity Sources
Evelyn R. Merritt
Journal of Nuclear Medicine Technology Jun 1989, 17 (2) 66-69;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Attenuator Calibration Factors Using High and Low Activity Sources
Evelyn R. Merritt
Journal of Nuclear Medicine Technology Jun 1989, 17 (2) 66-69;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Miniaturized Radiochemical Purity Testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-Tetrofosmin
  • Changes in Patterns of 99mTc-Macroaggregated Albumin Use Between 2000 and 2015
  • Absorbed Radiation Doses to Staff After Implementation of a Radiopharmacy Clean Room
Show more Radiopharmacy

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire