Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleBrief Communication

Combined Supine–Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy

Mary Beth Farrell
Journal of Nuclear Medicine Technology August 2024, jnmt.124.268017; DOI: https://doi.org/10.2967/jnmt.124.268017
Mary Beth Farrell
Intersocietal Accreditation Commission, Ellicott City, Maryland
CNMT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

The combined supine–prone imaging protocol for SPECT myocardial perfusion imaging offers significant advantages over supine imaging alone. By comparing supine and prone images, one can distinguish attenuation artifacts in the inferior and anterior walls from true perfusion defects, thus improving specificity and diagnostic accuracy. The recommended protocol is to perform prone imaging after supine stress imaging when perfusion defects are noted. The additional prone imaging time is 20%–40% less than the standard supine imaging time. Implementing prone imaging can optimize patient care and provide substantial benefits for nuclear cardiology labs, especially those without attenuation correction.

  • myocardial perfusion imaging
  • supine
  • prone
  • diaphragmatic attenuation
  • breast attenuation
  • artifact

Footnotes

  • Published online Aug. 13, 2024.

View Full Text

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

SNMMI members

SNMMI Member Login

Login to the site using your SNMMI member credentials

Individuals

Non-Member Login

Login as an individual user

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (1)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 1
March 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Combined Supine–Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Combined Supine–Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy
Mary Beth Farrell
Journal of Nuclear Medicine Technology Aug 2024, jnmt.124.268017; DOI: 10.2967/jnmt.124.268017

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Combined Supine–Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy
Mary Beth Farrell
Journal of Nuclear Medicine Technology Aug 2024, jnmt.124.268017; DOI: 10.2967/jnmt.124.268017
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • RATIONALE FOR PRONE IMAGING
    • PRONE IMAGING TECHNIQUE
    • PATIENT SELECTION FOR PRONE IMAGING
    • ADVANTAGES AND DISADVANTAGES OF PRONE MPI
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Patient Motion During Cardiac PET Imaging
  • Logistics of Adopting 177Lu-Vipivotide Tetraxetan Therapy in a Community-Based Hospital Setting
  • Fitness for Purpose of Text-to-Image Generative Artificial Intelligence Image Creation in Medical Imaging
Show more Brief Communication

Similar Articles

Keywords

  • myocardial perfusion imaging
  • supine
  • prone
  • diaphragmatic attenuation
  • breast attenuation
  • artifact
SNMMI

© 2025 SNMMI

Powered by HighWire