Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Study of Attenuation Correction Using a Cardiac Dynamic Phantom: Synchronized Time-Phase–Gated Attenuation Correction Method

Narihiro Hara, Masahisa Onoguchi, Hiroyuki Kawaguchi, Noriko Matsushima, Osamu Houjou, Masakazu Murai, Kohei Nakano and Wakana Makino
Journal of Nuclear Medicine Technology June 2024, 52 (2) 121-131; DOI: https://doi.org/10.2967/jnmt.123.266785
Narihiro Hara
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masahisa Onoguchi
2Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiroyuki Kawaguchi
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Noriko Matsushima
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Osamu Houjou
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masakazu Murai
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kohei Nakano
1Radiological Technology, Sumitomo Hospital, Osaka, Japan;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wakana Makino
3Department of Cardiology, Sumitomo Hospital, Osaka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

In cardiac nuclear medicine examinations, absorption in the body is the main factor in the degradation of the image quality. The Chang and external source methods were used to correct for absorption in the body. However, fundamental studies on attenuation correction for electrocardiogram (ECG)-synchronized CT imaging have not been performed. Therefore, we developed and improved an ECG-synchronized cardiac dynamic phantom and investigated the synchronized time-phase–gated attenuation correction (STPGAC) method using ECG-synchronized SPECT and CT images of the same time phase. Methods: As a basic study, SPECT was performed using synchronized time-phase–gated (STPG) SPECT and non–phase-gated (NPG) SPECT. The attenuation-corrected images were, first, CT images with the same time phase as the ECG waveform of the gated SPECT acquisition (with CT images with the ECG waveform of the CT acquisition as the reference); second, CT images with asynchronous ECG; third, CT images of the 75% region; and fourth, CT images of the 40% region. Results: In the analysis of cardiac function in the phantom experiment, left ventricle ejection fraction (heart rate, 11.5%–13.4%; myocardial wall, 49.8%–55.7%) in the CT images was compared with that in the STPGAC method (heart rate, 11.5%–13.3%; myocardial wall, 49.6%–55.5%), which was closer in value to that of the STPGAC method. In the phantom polar map segment analyses, none of the images showed variability (F(10,10) < 0.5, P = 0.05). All images were correlated (r = 0.824–1.00). Conclusion: In this study, we investigated the STPGAC method using a SPECT/CT system. The STPGAC method showed similar values of cardiac function analysis to the CT images, suggesting that the STPGAC method accurately reconstructed the distribution of blood flow in the myocardial region. However, the target area for attenuation correction of the heart region was smaller than that of the whole body, and changing the gated SPECT conditions and attenuation-corrected images did not affect myocardial blood flow analysis.

  • SPECT/CT system
  • myocardial blood flow
  • electrocardiography-synchronized CT imaging
  • synchronized time-phase–gated SPECT
  • synchronized time-phase–gated attenuation correction electrocardiogram

Footnotes

  • Published online Apr. 16, 2024.

View Full Text

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

SNMMI members

SNMMI Member Login

Login to the site using your SNMMI member credentials

Individuals

Non-Member Login

Login as an individual user

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 52 (2)
Journal of Nuclear Medicine Technology
Vol. 52, Issue 2
June 1, 2024
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Study of Attenuation Correction Using a Cardiac Dynamic Phantom: Synchronized Time-Phase–Gated Attenuation Correction Method
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Study of Attenuation Correction Using a Cardiac Dynamic Phantom: Synchronized Time-Phase–Gated Attenuation Correction Method
Narihiro Hara, Masahisa Onoguchi, Hiroyuki Kawaguchi, Noriko Matsushima, Osamu Houjou, Masakazu Murai, Kohei Nakano, Wakana Makino
Journal of Nuclear Medicine Technology Jun 2024, 52 (2) 121-131; DOI: 10.2967/jnmt.123.266785

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Study of Attenuation Correction Using a Cardiac Dynamic Phantom: Synchronized Time-Phase–Gated Attenuation Correction Method
Narihiro Hara, Masahisa Onoguchi, Hiroyuki Kawaguchi, Noriko Matsushima, Osamu Houjou, Masakazu Murai, Kohei Nakano, Wakana Makino
Journal of Nuclear Medicine Technology Jun 2024, 52 (2) 121-131; DOI: 10.2967/jnmt.123.266785
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Effectiveness of Data-Driven Gating FDG PET/CT for Abdominal Region
Show more Imaging

Similar Articles

Keywords

  • SPECT/CT system
  • myocardial blood flow
  • electrocardiography-synchronized CT imaging
  • synchronized time-phase–gated SPECT
  • synchronized time-phase–gated attenuation correction electrocardiogram
SNMMI

© 2025 SNMMI

Powered by HighWire