Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
OtherImaging (JNMT)

Fourier Phase Analysis of Dynamic Antral Contraction Scintigraphy: New Software, Normal Values and Comparisons to Conventional Gastric Emptying

Alan H Maurer, Paul Joseph Silver, Daohai Yu, Xiaoning Lu, Natalie Cole, Simindokht Dadparvar and Henry P Parkman
Journal of Nuclear Medicine Technology February 2023, jnmt.122.265037; DOI: https://doi.org/10.2967/jnmt.122.265037
Alan H Maurer
1 Temple University Hospital & Lewis Katz School of Medicine Temple University;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul Joseph Silver
2 Temple University Hospital and School of Medicine, United States;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daohai Yu
3 Center for Biostatistics & Epidemiology, Department of Biomedical Education and Data Science Lewis Katz School of Medicine Temple University;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Xiaoning Lu
3 Center for Biostatistics & Epidemiology, Department of Biomedical Education and Data Science Lewis Katz School of Medicine Temple University;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Natalie Cole
4 MIM Software;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Simindokht Dadparvar
5 Temple University Hospital & Lewis Katz School of Medicine Temple University Radiology;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Henry P Parkman
6 Temple University Hospital & Lewis Katz School of Medicine Temple University Gastroenterology Section; Parkinson Pavilion, 8th floor
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

Rationale: Dynamic antral contraction scintigraphy (DACS) has been used to evaluate for gastric dysmotility by measuring antral frequency and ejection fraction (EF). Fourier phase image analysis has the potential to assess gastric antral contractions for dyssynchrony as has been used for analyzing nuclear cardiology ventriculography(MUGA studies) for cardiac dyssynchrony. The aims of this study were to determine: 1) If Fourier phase analysis helps to characterize antral motility physiology; 2) If Fourier phase analysis correlates with conventional gastric emptying (GE); and 3) Which DACS parameters may aid in diagnosing gastric dysmotility, particularly delayed GE. Methods: DACS and GE studies of normal volunteers(n = 22) were compared to patients (n = 99) with symptoms of gastroparesis. New DACS Fourier phase analysis software was developed. Results: GE was delayed(n = 53) and normal(n = 46) in patients. There was a linear correlation of %Total of Proximal(P) and Distal(D) in-phase antral pixels @30 min(r = 0.37, P = 0.0001) and 60 min (r = 0.26, P = 0.007) with GE T1/2. In normals, the mean ratio P/D in-phase antral pixels increased from 1.67(30 min) to 2.65(120 min)(P = 0.035) and EF from 23%(30 min) to 32%(120 min)(P = 0.022). Multivariable regressions of %Total PD in-phase antral pixels (30 min) and EF(60 min) were best predictors of abnormal GE(adjusted odds ratio(95% CI):3.30(1.21, 9.00);2.97(1.08, 8.21)) respectively. Conclusion: This study used Fourier phase analysis to analyze DACS in normal subjects and patients with symptoms of gastroparesis. In addition to establishing normal values, new physiologic information on antral motility was obtained. In normal subjects, there is an increasing ratio of Proximal/Distal in-phase antral pixels and antral EF over time following meal ingestion. The % Total Proximal and Distal in-phase antral pixels at both 30 and 60 minutes had good correlation with T1/2 GE values. For symptomatic patients, the % Total Proximal and Distal in-phase antral pixels at 30 min and the EF at 60 min post meal ingestion correlated with delayed conventional GE. Thus, Fourier phase analysis of DACS appears to have potential to further aid in diagnosing gastric dysmotility in GE scintigraphy studies.

  • Gastrointestinal
  • Fourier analysis
  • antral contractility
  • antral dyssynchrony
  • gastric emptying scintigraphy
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 53 (1)
Journal of Nuclear Medicine Technology
Vol. 53, Issue 1
March 1, 2025
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Fourier Phase Analysis of Dynamic Antral Contraction Scintigraphy: New Software, Normal Values and Comparisons to Conventional Gastric Emptying
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Fourier Phase Analysis of Dynamic Antral Contraction Scintigraphy: New Software, Normal Values and Comparisons to Conventional Gastric Emptying
Alan H Maurer, Paul Joseph Silver, Daohai Yu, Xiaoning Lu, Natalie Cole, Simindokht Dadparvar, Henry P Parkman
Journal of Nuclear Medicine Technology Feb 2023, jnmt.122.265037; DOI: 10.2967/jnmt.122.265037

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Fourier Phase Analysis of Dynamic Antral Contraction Scintigraphy: New Software, Normal Values and Comparisons to Conventional Gastric Emptying
Alan H Maurer, Paul Joseph Silver, Daohai Yu, Xiaoning Lu, Natalie Cole, Simindokht Dadparvar, Henry P Parkman
Journal of Nuclear Medicine Technology Feb 2023, jnmt.122.265037; DOI: 10.2967/jnmt.122.265037
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Gastric Emptying Scintigraphy 2024: Still A Need for Compliance with Published Guidelines
  • Thank You, Readers, for Helping to Shape Future JNMT Content
  • Google Scholar

Similar Articles

Keywords

  • gastrointestinal
  • Fourier analysis
  • antral contractility
  • antral dyssynchrony
  • gastric emptying scintigraphy
SNMMI

© 2025 SNMMI

Powered by HighWire