Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleIMAGING

The Diagnostic Value of 99mTc-IgG Scintigraphy in the Diabetic Foot and Comparison with 99mTc-MDP Scintigraphy

Isa Neshandar Asli, Hamid Javadi, HamidReza Seddigh, Mehdi Mogharrabi, Aref Hooman, Mojtaba Ansari, Sara Jalallat and Majid Assadi
Journal of Nuclear Medicine Technology September 2011, 39 (3) 226-230; DOI: https://doi.org/10.2967/jnmt.110.085498
Isa Neshandar Asli
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hamid Javadi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
HamidReza Seddigh
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mehdi Mogharrabi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Aref Hooman
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mojtaba Ansari
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sara Jalallat
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Majid Assadi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Diabetic foot infection is the most common etiology of nontraumatic amputation of the lower extremities, and early diagnosis is of great importance in its management. The aim of this prospective study was to evaluate the strength of 99mTc-IgG scintigraphy in diagnosis of osteomyelitis of the diabetic foot and to compare 99mTc-IgG scintigraphy with 99mTc-methylene diphosphonate (MDP) scintigraphy. Methods: A prospective university hospital–based study was performed over 24 mo. Eighteen patients with type II diabetes and foot ulcers (15 men and 3 women; age range, 45–80 y) were referred for imaging because of clinically suspected osteomyelitis. Early (5-h) and late (24-h) 99mTc-IgG scanning and 3-phase skeletal scintigraphy were completed for all patients at a 3- to 4-d interval. Regions of interest over the involved bony sites and the contralateral normal sites were drawn, and the abnormal-to-normal ratios were acquired for both 99mTc-IgG and 99mTc-MDP studies. Results: From a total of 23 lesions, we observed 10 sites of osteomyelitis, 10 sites of cellulitis, and 3 sites of aseptic inflammation confirmed by MRI, clinical presentation, histopathologic examination, and follow-up evaluation as a gold standard. Both 99mTc-IgG and 99mTc-MDP scanning showed excellent sensitivity for diagnosis of osteomyelitis, but the specificity was significantly lower (69.2% and 53.8%, respectively). Sensitivity, specificity, and accuracy in the diagnosis of osteomyelitis were, respectively, 100%, 53.8%, 73.9% for 99mTc-MDP scanning; 100%, 69.2%, 82.6% for 5-h 99mTc-IgG scanning; and 60%, 76.9%, 69.5% for 24-h 99mTc-IgG scanning. There was no significant difference between the semiquantitative indices of 5-h and 24-h 99mTc-IgG scanning for inflammation, cellulitis, and osteomyelitis. Conclusion: Although both 99mTc-IgG and 99mTc-MDP scintigraphy have high sensitivity for the diagnosis of osteomyelitis, the specificity of these studies is poor. For 99mTc-IgG scintigraphy, 5-h images appear to be adequate, and there is little benefit to performing additional imaging at 24 h.

  • diabetic foot
  • osteomyelitis
  • 99mTc-IgG
  • 99mTc-MDP
  • semiquantitative

Peripheral neuropathy and metabolic and vascular disorders are important contributing factors leading to infection of obscured wounds in diabetic patients (1,2). When there is evidence of osteomyelitis, invasive procedures are needed to avoid amputation (3). Radiographic evaluation is not sensitive for the development of osteomyelitis, whereas labeled leukocyte imaging followed by bone marrow scintigraphy, although both sensitive and specific, is labor-intensive and limited by the risks associated with handling blood products (4). 111In-IgG and 99mTc-methylene diphosphonate (MDP) scintigraphy can be helpful for the diagnosis of inflammation and infection (5–11).

The aim of this prospective study was to assess the role of 99mTc-IgG scintigraphy in the diagnosis of osteomyelitis in the diabetic foot and to compare 99mTc-IgG scintigraphy with 99mTc-MDP scintigraphy. In addition to qualitatively assessing the 99mTc-MDP and 99mTc-IgG studies, we have attempted to evaluate the clinical usefulness of quantitative uptake on 99mTc-MDP and 99mTc-IgG scanning in detecting osteomyelitis in peripheral bony lesions.

MATERIALS AND METHODS

Participants

This study was conducted on 18 patients with type II diabetes who were referred to our nuclear medicine department with a clinical suspicion of osteomyelitis. The patients were recruited from a university hospital in Tehran from 2006 to 2008. They underwent 99mTc-IgG scanning first, followed by 3-phase 99mTc-MDP skeletal scanning at a 3- to 4-d interval.

The study complied with the declaration of Helsinki and was approved by the institutional ethics committee of Shaheed Beheshti University of Medical Science, and all patients gave written informed consent.

Imaging Protocols

99mTc-IgG Scintigraphy.

In both studies, the amount of intravenously injected 99mTc was about 740 MBq (20 mCi), and images were acquired by a double-head SPECT scintillation camera (Genesys; ADAC) with a low-energy all-purpose collimator using a matrix of 128 × 128 on a 20% window at a 140-keV peak. The intensity settings of the scintillation camera were carefully monitored so that images of comparable counts and intensities were available for interpretation. Three nuclear medicine consultants unaware of other data evaluated the scintigraphic studies and reached the final impression by consensus.

For 99mTc-IgG scintigraphy, a human nonspecific polyclonal immunoglobulin for intravenous administration was used. An IgG solution with a concentration of about 10 mg/mL in 0.01 M phosphate-buffered saline, pH 7.4, was prepared. 99mTc-IgG was prepared by adding 740 MBq (20 mCi) of 99mTc to an IgG kit provided by the Nuclear Energy Institute of Iran and incubating for 20 min at room temperature. 99mTc-IgG was administered intravenously, and early (5-h) and delayed (24-h) imaging was performed minimally in 2 views, for at least 400,000 counts and 50,000 counts, respectively. Images of the contralateral normal anatomic region were also obtained.

99mTc-MDP Scintigraphy.

Skeletal scans were obtained using 740 MBq of 99mTc-MDP. The first phase of the skeletal scan consisted of the radionuclide angiogram, comprising sequential images at 2–3 s per frame over the involved region of suspected osteomyelitis and the opposite presumed normal anatomic region. The flow phase was performed for 60 s, followed by a blood-pool image at 180 s after intravenous injection of the radiopharmaceutical. Delayed images were obtained 3 h after 99mTc-MDP injection using the same projections for at least 500,000 counts.

Visual Interpretation

The determination of osteomyelitis was based on significant uptake of radiopharmaceutical in all 3 phases of 99mTc-MDP scanning or an intense accumulation on 99mTc-IgG scanning (Fig. 1). Accumulation of radionuclide in only the first 2 phases of skeletal scanning or a mild to moderate uptake on 99mTc-IgG scanning was characterized as cellulitis (Fig. 2). If there was remarkable radionuclide uptake on 99mTc-MDP scanning without significant uptake on 99mTc-IgG scanning, aseptic inflammation was considered present (Fig. 3). Radionuclide uptake was characterized as absent (−), faint (±), moderate (+), or marked (++).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Example images of osteomyelitis (arrows). Significant uptake of 99mTc-MDP is seen in right first toe in all 3 phases of skeletal scintigraphy, accompanied by intense radiotracer uptake indicating osteomyelitis on 99mTc-IgG scan. (A) Flow phase of 99mTc-MDP skeletal scintigraphy. (B) Blood-pool phase of 99mTc-MDP bone scintigraphy. (C) Delayed phase of 99mTc-MDP skeletal scintigraphy. (D) Five-hour 99mTc-IgG scintigraphy. (E) Twenty-four-hour 99mTc-IgG scintigraphy.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Example images of cellulitis (arrows). Significant uptake of 99mTc-MDP is seen in left fifth metatarsi in flow and blood-pool phases of skeletal scintigraphy, but activity is normal in delayed phase and there is no significant uptake in same region on 99mTc-IgG scan. (A) Flow phase of 99mTc-MDP skeletal scintigraphy. (B) Blood-pool phase of 99mTc-MDP bone scintigraphy. (C) Delayed phase of 99mTc-MDP skeletal scintigraphy. (D) Five-hour 99mTc-IgG scintigraphy. (E) Twenty-four-hour 99mTc-IgG scintigraphy.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Example images of aseptic inflammation (arrows). Significant uptake of 99mTc-MDP is seen in dorsal aspect of left foot (talus bone) in all 3 phases of skeletal scintigraphy, but there is no significant uptake on 99mTc-IgG scan. (A) Flow phase of 99mTc-MDP skeletal scintigraphy. (B) Blood-pool phase of 99mTc-MDP bone scintigraphy. (C) Delayed phase of 99mTc-MDP skeletal scintigraphy. (D) Five-hour 99mTc-IgG scintigraphy. (E) Twenty-four-hour 99mTc-IgG scintigraphy.

Semiquantitative Analysis

Both 99mTc-MDP and 99mTc-IgG scans were further analyzed by drawing ellipsoid regions of interest over the suspected abnormal and contralateral normal bony sites. The entire lesion was included in the ellipsoid region, and mean counts per pixel in each region were measured. The mean uptake count ratios between abnormal and contralateral normal sites were also obtained; the ratios were calculated and considered to be indices, and the difference in indices for osteomyelitis, cellulitis, and inflammation in the scans were tested for significance.

The clinicians determined the final diagnosis by consensus, according to the MRI results, clinical presentation, wound culture results, histopathologic results, and follow-up results.

Statistical Analysis

Sensitivity, specificity, negative and positive predictive values, and accuracy were determined for each scan, and the potential differences in osteomyelitis, cellulitis, and aseptic inflammation on 99mTc-MDP scanning and on early and late 99mTc-IgG scanning were analyzed using ANOVA. A P value of less than 0.05 was considered significant. Statistical analysis was performed using an IBM computer and PASW software, version 18.0 (SPSS, Inc.).

RESULTS

The study included 3 women and 15 men (age range, 45–80 y). From a total of 23 lesions, we observed 10 sites of osteomyelitis, 10 sites of cellulitis, and 3 sites of aseptic inflammation, of which 2 were caused by Charcot joint (Table 1).

View this table:
  • View inline
  • View popup
TABLE 1

Scintigraphy Results

Both 99mTc-IgG and 99mTc-MDP scans showed excellent sensitivity for the diagnosis of osteomyelitis, but specificity was significantly compromised (69.2% and 53.8%, respectively). 99mTc-IgG scanning could differentiate osteomyelitis from cellulitis but not Charcot joint from osteomyelitis (Table 2). Sensitivity, specificity, and accuracy in the diagnosis of osteomyelitis were, respectively, 100%, 53.8%, and 73.9% for 99mTc-MDP scanning; 100%, 69.2%, and 82.6% for 5-h 99mTc-IgG scanning; and 60%, 76.9%, and 69.5% for 24-h 99mTc-IgG scanning.

View this table:
  • View inline
  • View popup
TABLE 2

Accuracy of Various Scintigraphy Procedures in Osteomyelitis Diagnosis

The osteomyelitis, cellulitis, and inflammation indices are reported in Table 3. We did not find any significant difference among the indices on 99mTc-MDP scintigraphy or on 5 h-and 24-h 99mTc-IgG scintigraphy (P > 0.5).

View this table:
  • View inline
  • View popup
TABLE 3

Osteomyelitis Indices in Various Scintigraphy Procedures

DISCUSSION

We observed that both 99mTc-MDP and 99mTc-IgG scanning can sensitively detect osteomyelitis; however, they lack the appreciated specificity. Datz et al., investigating 53 patients with assumed infection, reported that the sensitivity and specificity of 111In-IgG scanning was 97.9% and 94%, respectively. They found that this method can detect chronic and acute osteomyelitis with equal sensitivity, and simultaneous administration of antibiotics, steroids, and antiinflammatory agents or concurrent diabetes and renal dysfunction had no influence on scan sensitivity (6).

MRI can efficiently discriminate soft-tissue infection from bone involvement and can effectively detect the development of infection in anterior parts of the bone; however, efficacy is dramatically compromised at the midfoot and hindfoot (12–15). Despite high sensitivity, the application of MRI for the recognition of osteomyelitis in the diabetic foot is compromised by lower specificity regarding Charcot neuropathic osteoarthropathy. In addition, if there is an inflammatory hyperemia, the diagnostic accuracy is further decreased to 40%–50% (8).

Devillers et al., studying 56 diabetic foot ulcers in 40 patients, reported that the accuracy of radiography, 99mTc-MDP scintigraphy, and 99mTc-exametazime–conjugated leukocyte scintigraphy was 69.6%, 62.5%, and 92.9%, respectively. They concluded that leukocyte-labeling scintigraphy can be considered an outstanding technique for the identification of osteomyelitis in the diabetic foot and can be useful in follow-up evaluation because of an ability to predict osteomyelitis remission despite the lack of complete clinical regression of the diabetic ulcers (1). Although both sensitive and specific, leukocyte labeling scintigraphy followed by bone marrow scanning is also limited by inaccessibility, labor intensity, and the risk of infectious blood handling (4). Because of high sensitivity and the frequency of positive outcomes, the usefulness of labeled leukocyte imaging as a screening test is uncertain; supplementation of skeletal imaging by labeled leukocyte imaging has resulted in only marginal improvement of the test (14). Skeletal scanning can sensitively be applied for the determination of osteomyelitis but fails to differentiate diabetic osteomyelitis from other osteoarthropathic conditions because of higher bone turnover in both (16). There have been extensive reports about the usefulness of 99mTc-IgG scintigraphy in detecting a variety of infections, including those of the chest, abdomen, hip, and bone; however, as we also observed, this procedure might not be able to discriminate infection from aseptic inflammation (2,3,17,18). 111In-IgG scintigraphy differentiated infectious from sterile inflammatory processes in 25 adult patients with complicated osteomyelitis or septic arthritis with a sensitivity of 90% and specificity of 95% (19). Oyen et al. have reported that a recent bone trauma or fracture might be misleading in IgG scan interpretation (20–22). Unal et al., examining 20 cases of diabetic foot, reported a 100% versus 94% sensitivity and a 59% versus 100% specificity for 99mTc-IgG and 99mTc-white blood cell labeling, respectively (18). Correspondingly, we observed 4 cases of false-positive osteomyelitis, of which 2 were caused by cellulitis and 2 by aseptic infection, reflecting a lack of specificity of 99mTc-IgG scintigraphy. In a comprehensive study comparing 3 scanning techniques (triphasic skeletal scintigraphy, 99mTc-white blood cell scintigraphy, and 99mTc-IgG scintigraphy) in distinguishing musculoskeletal infection from noninfectious inflammation in 35 orthopedic patients, 2- to 6-h 99mTc-white blood cell scintigraphy and 20- to 24-h 99mTc-IgG scintigraphy had the greatest value (P < 0.01 and P < 0.016, respectively), with a sensitivity of 96.6% and 96.5%, respectively, and a specificity of 71% and 100%, respectively. The authors concluded that 99mTc-IgG scintigraphy might be an alternative to 99mTc-white blood cell scintigraphy because of its simplicity of preparation, similarity of accuracy, and safety, as well as its being better able to show the spread of inflammation into soft tissues (23).

We did not find any differences between the osteomyelitis, cellulitis, and aseptic inflammation indices in 5-h and 24-h 99mTc-IgG scanning. Therefore, it seems there is no need for delayed scintigraphy; one can evaluate the case with only a single scan.

Our study had some shortcomings, the most important of which were the relatively small sample size and the absence of bone biopsy as a gold standard, which may influence the results. However, we consider this problem to have been reduced by the compound use of MRI, clinical presentation, histopathologic examination, and follow-up evaluation. Further well-designed studies would seem useful.

CONCLUSION

Both 99mTc-IgG and 99mTC-MDP scanning can be applied to detect bone involvement in diabetic infection with excellent sensitivity; however, their specificity is compromised, especially in distinguishing between infection and inflammation. In addition, early 5-h images seem to be adequate in 99mTc-IgG scintigraphy, and there is no need for 24-h images.

Acknowledgments

We thank the colleagues at our institutes, especially Soodabeh Ramazani, Hamid Ahmadi, Yahya Nadiri, and Hossein Alizadeh, for technical help and data acquisition. This study was performed under the sponsorship of Shaheed Beheshti University of Medical Sciences (grant 1763). No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Jul. 27, 2011.

REFERENCES

  1. 1.↵
    1. Devillers A,
    2. Moisan A,
    3. Hennion F,
    4. Garin E,
    5. Poirier JY,
    6. Bourguet P
    . Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection. Eur J Nucl Med. 1998;25:132–138.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Palestro CJ,
    2. Torres MA
    . Radionuclide imaging in orthopedic infections. Semin Nucl Med. 1997;27:334–345.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Lipsky BA,
    2. Berendt AR,
    3. Deery HG,
    4. et al
    . Diagnosis and treatment of diabetic foot infections. Plast Reconstr Surg. 2006;117(7, suppl):212S–238S.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Dinh MT,
    2. Abad CL,
    3. Safdar N
    . Diagnostic accuracy of the physical examination and imaging tests for osteomyelitis underlying diabetic foot ulcers: meta-analysis. Clin Infect Dis. 2008;47:519–527.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Bruni C,
    2. Padovano F,
    3. Travascio L,
    4. Schillaci O,
    5. Simonetti G
    . Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis. Braz J Infect Dis. 2008;12:558–560.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Datz FL,
    2. Anderson CE,
    3. Ahluwalia R,
    4. et al
    . The efficacy of indium-111-polyclonal IgG for the detection of infection and inflammation. J Nucl Med. 1994;35:74–83.
    OpenUrlAbstract/FREE Full Text
  7. 7.
    1. Bryant R III.,
    2. Morales DL,
    3. Phalak K
    . Multimodality therapy for primary sternal osteomyelitis. Pediatr Infect Dis J. 2009;28:73–74.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Rozzanigo U,
    2. Tagliani A,
    3. Vittorini E,
    4. Pacchioni R,
    5. Brivio LR,
    6. Caudana R
    . Role of magnetic resonance imaging in the evaluation of diabetic foot with suspected osteomyelitis. Radiol Med. 2009;114:121–132.
    OpenUrlCrossRefPubMed
  9. 9.
    1. Strumas N,
    2. Antonyshyn O,
    3. Caldwell CB,
    4. Mainprize J
    . Multimodality imaging for precise localization of craniofacial osteomyelitis. J Craniofac Surg. 2003;14:215–219.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Newman LG,
    2. Waller J,
    3. Palestro CJ,
    4. et al
    . Leukocyte scanning with 111In is superior to magnetic resonance imaging in diagnosis of clinically unsuspected osteomyelitis in diabetic foot ulcers. Diabetes Care. 1992;15:1527–1530.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Newman LG,
    2. Waller J,
    3. Palestro CJ,
    4. et al
    . Unsuspected osteomyelitis in diabetic foot ulcers: diagnosis and monitoring by leukocyte scanning with indium in 111 oxyquinoline. JAMA. 1991;266:1246–1251.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Hovi I
    . Complicated bone and soft-tissue infections: imaging with 0.1 T MR and 99mTc-HMPAO-labeled leukocytes. Acta Radiol. 1996;37:870–876.
    OpenUrlCrossRefPubMed
  13. 13.
    1. Marcus CD,
    2. Ladam-Marcus VJ,
    3. Leone J,
    4. Malgrange D,
    5. Bonnet-Gausserand FM,
    6. Menanteau BP
    . MR imaging of osteomyelitis and neuropathic osteoarthropathy in the feet of diabetics. Radiographics. 1996;16:1337–1348.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Palestro CJ,
    2. Love C
    . Nuclear medicine and diabetic foot infections. Semin Nucl Med. 2009;39:52–65.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Palestro CJ,
    2. Love C,
    3. Miller TT
    . Infection and musculoskeletal conditions: imaging of musculoskeletal infections. Best Pract Res Clin Rheumatol. 2006;20:1197–1218.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Seabold JE,
    2. Flickinger FW,
    3. Kao SC,
    4. et al
    . Indium-111-leukocyte/technetium-99m-MDP bone and magnetic resonance imaging: difficulty of diagnosing osteomyelitis in patients with neuropathic osteoarthropathy. J Nucl Med. 1990;31:549–556.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Elgazzar AH,
    2. Abdel-Dayem HM,
    3. Clark JD,
    4. Maxon HR III.
    . Multimodality imaging of osteomyelitis. Eur J Nucl Med. 1995;22:1043–1063.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Unal SN,
    2. Birinci H,
    3. Baktiroglu S,
    4. Cantez S
    . Comparison of Tc-99m methylene diphosphonate, Tc-99m human immune globulin, and Tc-99m-labeled white blood cell scintigraphy in the diabetic foot. Clin Nucl Med. 2001;26:1016–1021.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Molina-Murphy IL,
    2. Palmer EL,
    3. Scott JA,
    4. et al
    . Polyclonal, nonspecific 111In-IgG scintigraphy in the evaluation of complicated osteomyelitis and septic arthritis. Q J Nucl Med. 1999;43:29–37.
    OpenUrlPubMed
  20. 20.↵
    1. Oyen WJ,
    2. Boerman OC,
    3. Subramanian R,
    4. et al
    . Biodistribution of 111In-labelled IgG and IgM in experimental infection. Nucl Med Commun. 1996;17:616–620.
    OpenUrlCrossRefPubMed
  21. 21.
    1. Oyen WJ,
    2. Netten PM,
    3. Lemmens JA,
    4. et al
    . Evaluation of infectious diabetic foot complications with indium-111-labeled human nonspecific immunoglobulin G. J Nucl Med. 1992;33:1330–1336.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Oyen WJ,
    2. Claessens RA,
    3. van der Meer JW,
    4. Rubin RH,
    5. Strauss HW,
    6. Corstens FH
    . Indium-111-labeled human nonspecific immunoglobulin G: a new radiopharmaceutical for imaging infectious and inflammatory foci. Clin Infect Dis. 1992;14:1110–1118.
    OpenUrlAbstract/FREE Full Text
  23. 23.↵
    1. Palermo F,
    2. Boccaletto F,
    3. Paolin A,
    4. et al
    . Comparison of technetium-99m-MDP, technetium-99m-WBC and technetium-99m-HIG in musculoskeletal inflammation. J Nucl Med. 1998;39:516–521.
    OpenUrlAbstract/FREE Full Text
  • Received for publication November 18, 2010.
  • Accepted for publication April 21, 2011.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 39 (3)
Journal of Nuclear Medicine Technology
Vol. 39, Issue 3
September 1, 2011
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Diagnostic Value of 99mTc-IgG Scintigraphy in the Diabetic Foot and Comparison with 99mTc-MDP Scintigraphy
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
The Diagnostic Value of 99mTc-IgG Scintigraphy in the Diabetic Foot and Comparison with 99mTc-MDP Scintigraphy
Isa Neshandar Asli, Hamid Javadi, HamidReza Seddigh, Mehdi Mogharrabi, Aref Hooman, Mojtaba Ansari, Sara Jalallat, Majid Assadi
Journal of Nuclear Medicine Technology Sep 2011, 39 (3) 226-230; DOI: 10.2967/jnmt.110.085498

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Diagnostic Value of 99mTc-IgG Scintigraphy in the Diabetic Foot and Comparison with 99mTc-MDP Scintigraphy
Isa Neshandar Asli, Hamid Javadi, HamidReza Seddigh, Mehdi Mogharrabi, Aref Hooman, Mojtaba Ansari, Sara Jalallat, Majid Assadi
Journal of Nuclear Medicine Technology Sep 2011, 39 (3) 226-230; DOI: 10.2967/jnmt.110.085498
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire