JNMT
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online May 11, 2007, 10.2967/jnmt.106.034918
doi:10.2967/jnmt.106.034918
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnmt.106.034918v1
35/2/80    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Botkin, C. D.
Right arrow Articles by Osman, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Botkin, C. D.
Right arrow Articles by Osman, M. M.
Journal of Nuclear Medicine Technology Volume 35, Number 2, 2007 80-83
© 2007 by Society of Nuclear Medicine

Prevalence, Challenges, and Solutions for 18F-FDG PET Studies of Obese Patients: A Technologist's Perspective

Crystal D. Botkin, CNMT, PET1 and Medhat M. Osman2

1 Nuclear Medicine Technology Program, Department of Medical Imaging and Radiation Therapeutics, Doisy College of Health Sciences, Saint Louis University, St. Louis, Missouri; and 2 Division of Nuclear Medicine, Department of Radiology, Saint Louis University, St. Louis, Missouri

Correspondence: For correspondence or reprints contact: Medhat M. Osman, MD, PhD, Nuclear Medicine, Department of Radiology, 3635 Vista Ave., St. Louis, MO 63110. E-mail: osmanmm{at}slu.edu

Obesity has reached epidemic proportions in the United States; hence, it is frequently encountered in patients undergoing 18F-FDG PET studies. The purpose of the current study was to present a technologist's perspective on the prevalence of obesity and the challenges and solutions in imaging obese patients in our PET facility. Methods: From October 2002 to October 2003, whole-body 18F-FDG PET was performed on 1,164 patients with a known or suspected malignancy. Images were acquired 45–60 min after 18F-FDG injection (7.4 MBq [0.2 mCi]/kg, with a maximum of 925 MBq [25 mCi]) on a PET scanner using a 4-min emission and 3-min transmission time per bed position. A database was maintained of patient height and weight, and body mass index (BMI) was calculated. Patient obesity was classified as overweight (BMI ≥ 25 kg/m2), obese (BMI ≥ 30 kg/m2), or malignantly obese (BMI ≥ 40 kg/m2). In addition, PET technologists recorded any problems and attempted solutions related to the patient weight. Results: BMI calculations showed that 528 patients (45.4%) were overweight or obese (322 men and 206 women; mean age, 55 y). Of those, 201 (38%) were overweight, 270 (51%) were obese, and 57 (11%) were malignantly obese. Problems encountered in these patients included difficult intravenous access (15%), difficult patient positioning (10%), patient motion (7%), an incomplete study (emission only) (1%), and potentially higher radiation exposure to the technologist because of extra time spent near the patient. Attempted solutions included adjusting the schedule to allow more time per patient, adjusting the dose based on body weight, using varied positioning techniques, dividing the study to allow a respite between different image combinations, and dividing time spent with obese patients among the technologists involved. Conclusion: Excessive body weight and related problems have commonly been encountered in our PET facility. 18F-FDG PET studies of obese patients represent an ongoing challenge, which requires patient-tailored solutions to avoid compromising image quality and risking higher radiation exposure to the technologists.

Key Words: 18F-FDG; PET; obesity; overweight; BMI