Comparison of performance of improved serum estimators of glomerular filtration rate (GFR) to 99mTc-DTPA GFR methods in patients with hepatic cirrhosis
Glomerular filtration rate (GFR) measurements are critical in patients with hepatic cirrhosis
but potentially erroneous when based on serum creatinine. New equations for estimated …
but potentially erroneous when based on serum creatinine. New equations for estimated …
Serum creatinine in patients with advanced liver disease is of limited value for identification of moderate renal dysfunction: are the equations for estimating renal …
J MacAulay, K Thompson, BA Kiberd… - Canadian Journal of …, 2006 - hindawi.com
BACKGROUND: The Cockcroft-Gault formula (CGF) is used to estimate the glomerular
filtration rate (GFR) based on serum creatinine (Cr) levels, age and sex. A new formula …
filtration rate (GFR) based on serum creatinine (Cr) levels, age and sex. A new formula …
Single-sample methods to measure GFR with technetium-99m-DTPA
Y Li, HB Lee, MD Blaufox - The Journal of Nuclear Medicine, 1997 - search.proquest.com
sample calculation of ERPF (r 2 0.905) than both the Schlegel Page 1 scintigraphic technique
and makes it difficult to discern improvements in tERPF estimation. Despite this. the complete …
and makes it difficult to discern improvements in tERPF estimation. Despite this. the complete …
Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA
K Itoh, S Tsushima, E Tsukamoto, N Tamaki - Annals of nuclear medicine, 2002 - Springer
The plasma sample method following a single injection of radioactive markers has been
proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in …
proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in …
Estimation in adults of the glomerular filtration rate in [99mTc]-DTPA renography-the rate constant method
O Carlsen - Rev. med. nucl. Alasbimn j, 2004 - pesquisa.bvsalud.org
The purpose of this study was to design an alternative and robust method for estimation of
glomerular filtration rate (GFR) in [99mTc]-diethylenetriaminepentaacetic acid ([99mTc] …
glomerular filtration rate (GFR) in [99mTc]-diethylenetriaminepentaacetic acid ([99mTc] …
Measurement of glomerular filtration rate using 99mTc-DTPA and the gamma camera: a comparison of methods
CD Russell, PG Bischoff, F Kontzen, KL Rowell… - European journal of …, 1985 - Springer
A variety of methods have been proposed to estimate the glomerular filtration rate (GFR)
from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare …
from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare …
Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis
Purpose To assess the accuracy of glomerular filtration rate (GFR) measurements obtained
with low–contrast agent dose dynamic contrast material–enhanced magnetic resonance …
with low–contrast agent dose dynamic contrast material–enhanced magnetic resonance …
[HTML][HTML] Comparative performance of FAS equation and Asian modified CKD-EPI in the determination of GFR in Chinese patients with CKD with the 99mTc-DTPA …
JQ Gao, FG Zhao, JM Huang, FQ Shao, P Xie - nefrologia, 2021 - Elsevier
Background Glomerular filtration rate (GFR) is a useful index in many clinical conditions.
However, very few studies have assessed the performance of full age spectrum (FAS) …
However, very few studies have assessed the performance of full age spectrum (FAS) …
Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
K Itoh - Annals of Nuclear Medicine, 2003 - Springer
Background: The gamma camera uptake method with Tc-99m-DTPA is simple and less time
consuming for the determination of the glomerular filtration rate (GFR). However, its …
consuming for the determination of the glomerular filtration rate (GFR). However, its …
How to estimate renal function in patients with liver disease: choosing the most suitable equation
S Ren, Y Chang, Q Zhang, X Wang, H Niu… - … urology and nephrology, 2019 - Springer
Abstract Background Hepatitis B virus (HBV) infection is a public health challenge,
especially in China. In clinical practice, HBV infection is associated with nephropathy …
especially in China. In clinical practice, HBV infection is associated with nephropathy …
Related searches
- 99mtc dtpa hepatic cirrhosis
- 99mtc dtpa filtration rate
- filtration rate hepatic cirrhosis
- 99mtc dtpa serum estimators
- 99mtc dtpa comparison of performance
- serum estimators hepatic cirrhosis
- filtration rate serum estimators
- filtration rate comparison of performance
- comparison of performance hepatic cirrhosis
- serum estimators comparison of performance
- 99mtc dtpa ckd epi
- 99mtc dtpa determination of gfr
- 99mtc dtpa chinese patients
- 99mtc dtpa plasma clearance
- 99mtc dtpa systematic difference
- 99mtc dtpa 51cr edta