Evaluation of zeta-potential and particle size of technetium 99mTc-sulfur colloid subsequent to the addition of lidocaine and sodium bicarbonate
VS Loveless, CP Surdock… - Journal of Nuclear …, 2010 - Soc Nuclear Med
The use of 99mTc-sulfur colloid lymphoscintigraphy for the determination of lymph flow
patterns from a tumor site and localization of the sentinel node has been widely adopted …
patterns from a tumor site and localization of the sentinel node has been widely adopted …
[PDF][PDF] Technetium-99m-sulfur colloid for lymphoscintigraphy: effects of preparation parameters
D Eshima, LA Eshima, NM Gotti, SC Herda… - Journal of Nuclear …, 1996 - Soc Nuclear Med
There has been a resurgence inthe use of lymphoscintigraphy for the external detection of
lymph nodes for metastatic melanoma and breast tumors. Technetium-99m-antimony …
lymph nodes for metastatic melanoma and breast tumors. Technetium-99m-antimony …
Stability of a mixture of technetium Tc 99m sulfur colloid and lidocaine hydrochloride
JV Dura, GH Hinkle - American Journal of Health-System …, 2007 - academic.oup.com
Purpose. The stability of a mixture of technetium Tc 99m sulfur colloid and lidocaine
hydrochloride for up to eight hours was studied. Methods. Three vials of technetium Tc 99m …
hydrochloride for up to eight hours was studied. Methods. Three vials of technetium Tc 99m …
Buffered Tc-99m sulfur colloid substantially reduces the pain of lymphoscintigraphy injections
M Stokes, D Jansons, D Gilmore, K Donohoe - 2008 - Soc Nuclear Med
2028 Objectives: Lymphoscintigraphy involves the injection of Tc-99m sulfur colloid (SC) at
multiple sites. Injection protocols vary between institutions, but 8 injections for breast cancer …
multiple sites. Injection protocols vary between institutions, but 8 injections for breast cancer …
[PDF][PDF] Filtered technetium-99m-sulfur colloid evaluated for lymphoscintigraphy
JC Hung, GA Wiseman, HW Wahner… - Journal of Nuclear …, 1995 - Soc Nuclear Med
Several Â@ rc-labeled radiopharmaceuticals have been devel oped for lymphoscintigraphy
of the extremities. In the United States, however, these agents are notwuielyused din@ alty …
of the extremities. In the United States, however, these agents are notwuielyused din@ alty …
Particle size analysis of 99mTc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application
C Tsopelas - Journal of nuclear medicine, 2001 - Soc Nuclear Med
Colloidal particle size is an important characteristic to consider when choosing a
radiopharmaceutical for mapping sentinel nodes in lymphoscintigraphy. Methods: Photon …
radiopharmaceutical for mapping sentinel nodes in lymphoscintigraphy. Methods: Photon …
Sentinel lymph node uptake of two different technetium-labeled radiocolloids
S David Nathanson, P Anaya, KC Karvelis… - Annals of surgical …, 1997 - Springer
Background: The study was designed to compare the uptake of technetium-99m-labeled
human serum albumin ([99m Tc] HSA) and 99m technetium-labeled sulfur colloid ([99m Tc] …
human serum albumin ([99m Tc] HSA) and 99m technetium-labeled sulfur colloid ([99m Tc] …
Microwave preparation of technetium-99m sulfur colloid
GJ Morrissey, JE Powe - Journal of nuclear medicine technology, 1992 - Soc Nuclear Med
Technetium-99m sulfur colloid (99mTc-SC) has been useful in reticuloendothelial imaging,
and in particular in liver/spleen and more recently bone marrow scintigraphy. Technetium …
and in particular in liver/spleen and more recently bone marrow scintigraphy. Technetium …
Particle-size and radiochemical purity evaluations of filtered 99mTc-sulfur colloid prepared with different heating times
MM Michenfelder, LJ Bartlett… - Journal of Nuclear …, 2014 - Soc Nuclear Med
Sentinel node lymphoscintigraphy using colloidal particles has become common practice at
many institutions. The ideal particle size for colloids such as filtered 99mTc-sulfur colloid …
many institutions. The ideal particle size for colloids such as filtered 99mTc-sulfur colloid …
Evaluation of compatibility and stability of filtered 99mTc-sulfur colloid when combined with fluorescent indocyanine green dye
KM Hegseth, AM Warren, JC Hung… - Journal of Nuclear …, 2012 - Soc Nuclear Med
It is a common practice to administer dyes and radiopharmaceuticals separately for the
localization of sentinel nodes in patients with biliary tract malignancies. The objective of this …
localization of sentinel nodes in patients with biliary tract malignancies. The objective of this …
Related searches
- addition of lidocaine 99mtc sulfur
- particle size 99mtc sulfur
- zeta potential 99mtc sulfur
- sodium bicarbonate 99mtc sulfur
- sodium bicarbonate zeta potential
- particle size zeta potential
- addition of lidocaine zeta potential
- addition of lidocaine sodium bicarbonate
- particle size sodium bicarbonate
- addition of lidocaine particle size
- purity evaluations 99mtc sulfur
- technetium 99m sulfur colloid
- breast lymphoscintigraphy 99mtc sulfur
- compatibility and stability 99mtc sulfur
- preparation and utilization 99mtc sulfur
- microwave preparation sulfur colloid