Adsorption of 99mTc-sestamibi onto plastic syringes: evaluation of factors affecting the degree of adsorption and their impact on clinical studies

TN Swanson, DT Troung, A Paulsen… - Journal of nuclear …, 2013 - Soc Nuclear Med
The purpose of this study was to document the extent of adhesion of 99mTc-sestamibi to
syringes in patient procedures, determine factors that influence the degree of adhesion, and …

Adsorption of radiopharmaceuticals to syringes: setting up a reliable protocol for its assessment

TG Stopar, A Socan, PK Peitl - Nuclear medicine communications, 2007 - journals.lww.com
Background It is well known that various drugs, including radiopharmaceuticals, may adsorb
to plastic syringes to different extents. Some reports suggest that adsorption can reach levels …

Adsorption of some technetium-99m radiopharmaceuticals onto disposable plastic syringes

BA Jansson, MB Göransson… - Journal of nuclear …, 1998 - Soc Nuclear Med
Objective: The purpose of this study was to determine the adsorption behavior of some
widely used, commercially available 99mTc radiopharmaceuticals onto different types of …

Adsorption of 99mTc-radiopharmaceuticals onto injection vials and syringes

A Mushtaq, T ur Rehman, MS Mansur… - Journal of nuclear …, 2008 - Soc Nuclear Med
Many groups have reported the adsorption or retention of 99mTc-radiopharmaceuticals on
injection vials and disposable plastic syringes. Such an enormously high loss of radioactivity …

The adsorption of 99Tcm dimercaptosuccinic acid onto injection vials.

AM Millar - Nuclear Medicine Communications, 1984 - europepmc.org
It is common practice to dispense radiopharmaceuticals into empty sterile vials for dispatch
to the departments where they are to be administered. It has been noted that on withdrawal …

Retention of 99mTc-DMSA (III) and 99mTc-nanocolloid in different syringes affects imaging quality

M Bauwens, I Pooters, J van der Pol… - Nuclear Medicine …, 2014 - journals.lww.com
Abstract 99m Tc-dimercaptosuccinic acid [DMSA (III)] and colloidal human serum albumin
(99m Tc-nanocolloid) are widely used radiopharmaceuticals. Recently, in our institution we …

The effect of selected preparation variables on the radiochemical purity of 99mTc-sestamibi

JP Norenberg, MP Vaidya, WB Hladik… - Journal of nuclear …, 2005 - Soc Nuclear Med
Objective: Measurement of cardiac perfusion via agents such as 99mTc-sestamibi
(Cardiolite; DuPont-Merck Pharmaceutical Co., Inc.) is widely used in clinical nuclear …

Generator eluate effects on the labeling efficiency of 99mTc-sestamibi

JC Hung, TJ Herold, ME Wilson, RJ Gibbons - Nuclear medicine and …, 1995 - Elsevier
Our nuclear pharmacy noted that 99mTc-sestamibi kits sometimes failed radiochemical
purity (RCP) testing (ie, RCP< 90%). All failed kits had been prepared with eluate from a …

Optimal conditions of 99mTc eluate for the radiolabeling of 99mTc-sestamibi

JC Hung, TJ Herold, RJ Gibbons - Nuclear medicine and biology, 1996 - Elsevier
Our nuclear pharmacy has reported that a failed radiochemical purity (RCP)(ie, RCP< 90%)
of 99mTc-sestamibi may be associated with the use of a first elution at later stages from a …

Evaluation of the stability of 99mTc-ECD and stabilized 99mTc-HMPAO stored in syringes

IL Koslowsky, SE Brake, SJ Bitner - Journal of nuclear medicine …, 2001 - Soc Nuclear Med
Objective: To determine and compare the stability of 99mTc-ECD and stabilized 99mTc-
HMPAO when stored in syringes over an 8-h period. Methods: 99mTc-ECD and stabilized …