Occult intestinal bleeding imaged by technetium-99m-HSA-D radionuclide angiography: a case report
S Mizuno, H Ikehira, T Aoki, H Ito… - Journal of nuclear …, 1998 - Soc Nuclear Med
Radionuclide angiography (RNA) with 99mTc-diethylenetriamine pentaacetic acid human
serum albumin (99mTc-HSAD) is a sensitive screening method for diagnosing systemic …
serum albumin (99mTc-HSAD) is a sensitive screening method for diagnosing systemic …
[PDF][PDF] Acute gastrointestinal hemorrhage detected by selective scintigraphic angiography
JKS George, JS Pollak - Journal of Nuclear Medicine, 1991 - Soc Nuclear Med
Sections of Nuclear Medicine, Albany Medical Center, Albany. New York and lnterventional
Radiology, Department of Diagnostic Radiology, Yale-New Haven Hospital, Yale University …
Radiology, Department of Diagnostic Radiology, Yale-New Haven Hospital, Yale University …
Localization of gastrointestinal bleeding using Tc-99m HSA-DTPA SPECT and maximum-intensity projection imaging
S Ha-Kawa, T Yoshida, Y Aoki, M Sougawa… - Clinical nuclear …, 2002 - journals.lww.com
When radionuclide imaging is performed using Tc-99m-labeled erythrocytes or human
serum albumin, serial planar images are routinely acquired to detect the site of …
serum albumin, serial planar images are routinely acquired to detect the site of …
SPECT/CT imaging in 99mTc-HSA-DTPA gastrointestinal bleeding scintigraphy to localize bleeding sites
Y Yamamoto, Y Nishiyama - European journal of nuclear medicine and …, 2012 - Springer
The present case was a 62-year-old man who presented with relapsing severe colonic
diverticular bleeding. A diverticulum with fresh coagula was identified in the ascending colon …
diverticular bleeding. A diverticulum with fresh coagula was identified in the ascending colon …
The clinical utility of nuclear medicine imaging for the detection of occult gastrointestinal haemorrhage
DM Howarth, K Tang, W Lees - Nuclear medicine communications, 2002 - journals.lww.com
Acute gastrointestinal bleeding is often intermittent and the bleeding source may be difficult
to locate, resulting in delay of potentially life-saving treatment. The aim of this study was to …
to locate, resulting in delay of potentially life-saving treatment. The aim of this study was to …
Localization of small bowel bleeding by arterial injection of Tc-99m-labeled RBC
K Saito, K Koizumi, Y Goto, K Yamamoto… - Annals of nuclear …, 1999 - Springer
A 79-year-old man with melena was suspected of having small bowel bleeding because
upper and lower endoscopic findings were negative. Technetium-99m-labeled red blood …
upper and lower endoscopic findings were negative. Technetium-99m-labeled red blood …
[CITATION][C] Pitfalls of gastrointestinal bleeding studies with 99mTc-labeled RBCs
ML Lecklitner, JJ Hughes - Seminars in Nuclear Medicine, 1986 - Elsevier
A 52-YEAR-OLD woman presented with a five-day history of dark stools and nausea.
Physical examination revealed a blood pressure of 148/106 mm Hg, pulse of 84/rain, and …
Physical examination revealed a blood pressure of 148/106 mm Hg, pulse of 84/rain, and …
Localization of intestinal bleeding using a fusion of Tc-99m-labeled RBC SPECT and X-ray CT
N Yama, E Ezoe, Y Kimura, M Mukaiya… - Clinical nuclear …, 2005 - journals.lww.com
Although Tc-99m-labeled RBC SPECT is sensitive for detection of intestinal bleeding, it
cannot provide a high degree of specific anatomic information. We present a case of …
cannot provide a high degree of specific anatomic information. We present a case of …
Technical Considerations of Tc-99m Labeled Red Blood Cell Scans in the Detection and Localization of Gastrointestinal Bleeding Sites
AJ Rousseau, HD Royal, JA Parker… - Journal of nuclear …, 1984 - Soc Nuclear Med
Arteriography to detect gastrointestinal bleeding, which is often intermittent, is only likely to
yield diagnostically useful information if the patient is actively bleeding at a rate of greater …
yield diagnostically useful information if the patient is actively bleeding at a rate of greater …
Scintigraphic demonstration of acute gastrointestinal bleeding
A Alavi - Gastrointestinal Radiology, 1980 - Springer
Acute gastrointestinal bleeding may be localized using noninvasive radionuclide methods.
We have favored the use of technetium-99m sulfur colloid with sequential imaging because …
We have favored the use of technetium-99m sulfur colloid with sequential imaging because …