Stability of Stabilized 99mTc-d, l-HMPAO Stored in Vials and Syringes

M del Carmen Plancha-Mansanet… - Journal of nuclear …, 2008 - Soc Nuclear Med
Our objective was to determine the stability of stabilized 99mTc-hexamethylpropylene amine
oxime (99mTc-d, l-HMPAO) dispensed by vial and syringe, with the storage time and …

Evaluation of the stability of 99mTc-ECD and stabilized 99mTc-HMPAO stored in syringes

IL Koslowsky, SE Brake, SJ Bitner - Journal of nuclear medicine …, 2001 - Soc Nuclear Med
Objective: To determine and compare the stability of 99mTc-ECD and stabilized 99mTc-
HMPAO when stored in syringes over an 8-h period. Methods: 99mTc-ECD and stabilized …

Radiochemical purity and stability of 99mTc-HMPAO in routine preparations

L Uccelli, P Martini, M Pasquali, A Boschi - Journal of Radioanalytical and …, 2017 - Springer
The aim of this work was to investigate the influence of pH, recovery volume, type of saline
solution plastic or glass container, used to prepare the technetium-99m-d, l …

A comparison of three methods to determine the radiochemical purity of 99Tcm-hexamethylpropylene amine oxime (99Tcm-HMPAO)

G Mah, RM Reilly, GLM Wong… - Nuclear Medicine …, 1989 - journals.lww.com
Determining the radiochemical purity of 99 Tc m-HMPAO using the standard method
suggested by the manufacturer of the HMPAO kit is slow, consuming much of the 30 min …

Radiochemical purity and stability of 99mTc-HMPAO preparations: the influence of pH, volume recovery, and storage conditions

AL Viglietti, G Perlo, C Augeri, C Massara… - Healthcare …, 2012 - sfera.unife.it
OBJECT. The aim of this work was to study the influence of the nature (pH, plastic or glass
ampoules) of 0, 9% NaCl sodium chloride injection used to dilute generator produced …

Stabilisation of high-activity99mTc-d,I-HMPAO preparations with cobalt chloride and their biological behaviour

KO Mang'Era, HP Vanbilloen, CW Schiepers… - European journal of …, 1995 - Springer
It has been reported that the stability of a 1.11-GBq (30 mCi) technetium-99m d, l-
hexamethylpropylene amine oxime (HMPAO) preparation can be improved to up to 5 h by …

Study on Labeling Efficiency of -HMPAO

JH Hyeon, HJ Lim, HK Kim, SU Cho… - The Korean Journal of …, 2012 - koreascience.kr
Purpose: The labeling efficiency of radiopharmaceuticals in nuclear medicine is important in
terms of accuracy and reliability of the examination. Usually $^{99m} Tc $-HMPAO used for …

[PDF][PDF] Validation of a column method for technetium-99m exametazime quality control.

G Pandos, S Penglis, C Tsopelas - Journal of nuclear medicine …, 1999 - Soc Nuclear Med
Objective: The purpose of this study was to investigate if an octadecyl (18C) minicolumn
could be applied successfully for quality control of 99mTc exametazime (HMPAO). Methods …

[PDF][PDF] Sensitivity of technetium-99m-d, l-HMPAO to radiolysis in aqueous solutions

K Tubergen, M Corlija, WA Volkert… - Journal of Nuclear …, 1991 - Soc Nuclear Med
MATERIALSAND METHODS Technetium-99m-d, 1-HMPAO was prepared from a com
mercial kit (Ceretece, Amersham Intl., Arlington Heights, IL) containing 0.5 mg of d, l-4, 8 …

Miniaturized radiochemical purity testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-tetrofosmin

A de la Fuente, R Zanca, R Boni… - Journal of Nuclear …, 2017 - Soc Nuclear Med
Quick methods are functional in clinical practice to ensure the fastest availability of
radiopharmaceuticals. For this purpose, we investigated the radiochemical purity of the …