Radioactive contamination of packing materials from a xenon-133 shipment.

MT Hackett, SL Magoun - Journal of Nuclear Medicine Technology, 2000 - Soc Nuclear Med
We report on radioactive contamination of packing materials from a 133Xe shipment. A 2-
vial 133Xe shipment was monitored using a survey meter before opening. Both vials were …

Radioxenon packaging contamination

RP Lieto, N Morrison - Journal of nuclear medicine technology, 1985 - Soc Nuclear Med
Xenon-133 in multiple unit-dose vials is a commonly employed radionuclide in nuclear
medicine. Because it is an inert gas, shipments of radioxenon for nuclear medicine …

Large dose errors due to redistribution of 133Xe in carpules and plastic syringes

J Keaney, A Liuzzi, GS Freedman - Journal of Nuclear Medicine, 1971 - Soc Nuclear Med
MATERIALS AND METHODS Xenon-133 dissolved in a saline solution is de livered weekly
in a cylindrical glass carpule. The carpule contains a rubber stopper at one end and a …

Stability of Xenon-127 in Unit Dose Vials

RJ Kowalsky - Journal of Nuclear Medicine Technology, 1979 - Soc Nuclear Med
The stability of Xe-127 in unit dose vials—filled and stored under various conditions—was
studied. Vials stored for 40 days retained between 50% and 98% of the original xenon …

Radiation hazards associated with syringes used to store and dispense/sup 133/Xe

AR Benedetto, AJ Landry Jr - Health Phys.;(United Kingdom), 1984 - osti.gov
Xenon-133 gas and xenon-133 gas dissolved in saline are widely used in nuclear medicine
for the evaluation of the pulmonary system and, less frequently, for the measurement of …

Exposure to Xenon 133 in the nuclear medicine laboratory.

H Nishiyama, SJ Lukes - Radiology, 1982 - pubs.rsna.org
Exposure of nuclear medicine personnel to 133X was examined quantitatively at three area
hospitals during ventilation-perfusion studies in which the technologists breathed through a …

Preparation of xenon-133 solution for intravenous administration

TJ Herold, MK Dewanjee… - Journal of nuclear …, 1985 - Soc Nuclear Med
A method for routine preparation of a solution of 133Xe gas in saline from commercially
available 133Xe gas ampoules is described and evaluated. At room temperature and …

Precautions for avoiding 133Xe release from charcoal xenon traps

GM Timpe - Journal of Nuclear Medicine Technology, 1976 - Soc Nuclear Med
Discussion From our development work we have concluded and recommend the following. l.
All xenon traps will saturate, which will subsequently result in dumping of 133Xe into the …

[PDF][PDF] A simple method for the air monitoring of xenon-133

JG Jacobstein - Journal of Nuclear Medicine, 1979 - Soc Nuclear Med
MATERIALS AND METhODS Red-top Vacutainers rated at 10cc were used. To measure the
Xe-I33 content of the air at a given place and time a technologist inserted an open-ended …

A new instrument for survey monitoring of airborne xenon-133

MS Bolmsjo, BRR Persson - Physics in Medicine & Biology, 1982 - iopscience.iop.org
Methods are reviewed for measuring xenon-133 contamination of the air in medical clinics.
The principles of a new, simple, and low cost monitor are outlined. Results from …