Could different hydration protocols affect the quality of 18F-FDG PET/CT images?

L Ceriani, S Suriano, T Ruberto… - Journal of Nuclear …, 2011 - Soc Nuclear Med
In a group of oncologic patients undergoing 18F-FDG PET/CT, we compared 4 different
protocols of hydration to investigate their impact on image quality and to choose the best …

Technical improvements in fluorine-18-FDG PET imaging of the abdomen and pelvis

GP Leisure, HJ Vesselle, PF Faulhaber… - Journal of nuclear …, 1997 - Soc Nuclear Med
PET tumor imaging of the abdomen and pelvis is prone to artifacts due to urinary tract
activity. A new technique has been developed to reduce such artifacts and enhance study …

The effect of furosemide dose timing on bladder activity in oncology imaging with 18F-fluorodeoxyglucose PET/CT

S Nijjar, J Patterson, J Ducharme… - Nuclear medicine …, 2010 - journals.lww.com
Objective To compare the effects of two furosemide administration protocols on bladder
activity during 18 F-fluorodeoxyglucose (18 F-FDG) PET/computed tomography (CT) …

Effect of forced diuresis during 18F-DCFPyL PET/CT in patients with prostate cancer: activity in ureters, kidneys and bladder and occurrence of halo artefacts around …

M Wondergem, FM van der Zant… - Nuclear Medicine …, 2019 - journals.lww.com
Forced diuresis may improve readability of 2-(3-(1-carboxy-5-[(6-[18 F] fluoro-pyridine-3-
carbonyl)-amino]-pentyl)-ureido)-pentanedioic acid (18 F-DCFPyL) PET/computed …

Intravenous furosemide injection during 18F-FDG PET acquisition

S López-Gandul, G Pérez-Moure… - Journal of nuclear …, 2006 - Soc Nuclear Med
Urinary-system elimination of 18F-FDG can be mistaken for pathologic uptake. Furosemide
helps eliminate this artifact. Unnecessary administration should be avoided. Our approach …

Optimization of urinary FDG excretion during PET imaging

JK Moran, HB Lee, MD Blaufox - The Journal of Nuclear …, 1999 - search.proquest.com
Accumulation of fluorodeoxyglucose (FDG) activity in the urine interferes with the
visualization of pelvic and, sometimes, abdominal abnormalities. Although this is a major …

The impact of acquisition time on image quality in whole-body 18F-FDG PET/CT for cancer staging

D Hausmann, DJ Dinter, M Sadick… - Journal of Nuclear …, 2012 - Soc Nuclear Med
Our objective was to evaluate the impact of acquisition time on image quality, lesion
detection rate, standardized uptake values, and lesion volume for 18F-FDG PET in cancer …

Clinical 18F-FDG oncology patient preparation techniques

SM Hamblen, VJ Lowe - Journal of nuclear medicine technology, 2003 - Soc Nuclear Med
Objectives: Clinical tumor imaging with 18F-FDG in PET is growing in demand. This article
will provide a review of current patient preparation and imaging techniques. The goal is to …

Impact of 18F-FDG PET/CT with retrograde filling of the urinary bladder in patients with suspected pelvic malignancies

AMG Vicente, AS Castrejón, AP Muñoz… - Journal of Nuclear …, 2010 - Soc Nuclear Med
The purpose of this study was to assess the feasibility of selective pelvic PET/CT with
retrograde bladder irrigation in evaluating pelvic pathologies. Methods: Thirty-eight patients …

Forced diuresis improves the diagnostic accuracy of 18F-FDG PET in abdominopelvic malignancies

EM Kamel, P Jichlinski, JO Prior… - Journal of Nuclear …, 2006 - Soc Nuclear Med
Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of
abdominopelvic 18F-FDG PET. Methods: Thirty-two patients were enrolled. Besides the …