A rapid radiochemical purity testing method for 99mTc-tetrofosmin

LA Eggert, MD Dick, DW Mahoney… - Journal of Nuclear …, 2010 - Soc Nuclear Med
The standard radiochemical purity (RCP) testing method for 99mTc-tetrofosmin as described
in the package insert requires extensive time (20–30 min) and considerable skill to achieve …

An alternative to the reference method for testing the radiochemical purity of 99Tcm-tetrofosmin

A Ramirez, T Arroyo, JP Diaz-Alarcon… - Nuclear medicine …, 2000 - journals.lww.com
The recommended method for controlling the radiochemical purity (RCP) of 99 Tc m-
labelled tetrofosmin is thin-layer chromatography (TLC) with silica gel as the stationary …

A better method of quality control for 99mTc-tetrofosmin

R Hammes, LA Joas, TE Kirschling… - Journal of nuclear …, 2004 - Soc Nuclear Med
The method of quality control (QC) described on the package insert for 99mTc-tetrofosmin
requires meticulous attention to technique for accurate radiochemical purity results. About …

Rapid quality control for testing the radiochemical purity of 99Tcm-tetrofosmin

T Métayé, M Desmarquet - Nuclear medicine communications, 2001 - journals.lww.com
We describe a new thin-layer chromatography (TLC) method to evaluate the radiochemical
purity of 99 Tc m-tetrofosmin without the drawbacks of toxicity, solvent ratios and time …

An alternative method for determining the radiochemical purity of 99mTc-tetrofosmin

KC Amin, S Patel, A Doke, GB Saha - Journal of Nuclear Medicine …, 2011 - Soc Nuclear Med
The instant thin-layer chromatographic method of determining the radiochemical purity of
99mTc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and …

99Tcm-tetrofosmin: evaluation of fractionated cold kits and two new methods of quality control

S Penglis, C Tsopelas - Nuclear Medicine Communications, 2000 - journals.lww.com
The fractionation of Myoview™ into 1: 5 was followed by storage at− 80 C for 3 months. The
kits were reconstituted with 3.5 GBq 99 Tc m-pertechnetate and the average radiochemical …

Rapid quality control of technetium-99m-tetrofosmin: comparison of miniaturized and standard chromatography systems

MC Geyer, AM Zimmer, WG Spies… - Journal of nuclear …, 1995 - Soc Nuclear Med
Objective: In this paper, we evaluate the use of miniaturized ITLC-SG strips (10 cm x 1 cm)
with the same solvent system of methylene chloride: acetone (65: 35) to reduce the time …

Modified preparation and rapid quality control test for technetium-99m-tetrofosmin

M Patel, A Owunwanne, M Tuli… - Journal of nuclear …, 1998 - Soc Nuclear Med
Objective: The objectives of this study were to: modify the preparation of 99mTc-tetrofosmin
by using twice the amount of 99mTcO4− recommended by the manufacturer; evaluate the …

Rapid miniaturized chromatography for technetium-99m-tetrofosmin

BF McKay, AM Zimmer, SM Spies - Journal of Nuclear Medicine …, 1997 - Soc Nuclear Med
The purpose of this investigation was to develop and evaluate a new and rapid miniaturized
chromatography system that would accurately assess the radiochemical purity of 99mTc …

Technetium-99m-tetrofosmin: retention of nitrogen atmosphere in kit vial as a cause of poor quality material

T Murray, AA Bolster, TE Hilditch… - Nuclear medicine …, 2000 - journals.lww.com
Abstract Technetium-99m (99 Tc m)-tetrofosmin was prepared using four different
reconstitution methods. The radiochemical purity (RCP) of these products was assessed 8 h …