A comparison of the uniformity requirements for SPECT image reconstruction using FBP and OSEM techniques

LK Leong, RL Kruger, MK O'Connor - Journal of nuclear medicine …, 2001 - Soc Nuclear Med
Objective: Gamma camera nonuniformity can result in the presence of ring artifacts in
reconstructed SPECT images. The objective of this study is to compare the relationship …

Critical examination of the uniformity requirements for single‐photon emission computed tomography

MK O'Connor, C Vermeersch - Medical physics, 1991 - Wiley Online Library
It is generally recognized that single‐photon emission computed tomography (SPECT)
imposes very stringent requirements on gamma camera uniformity to prevent the occurrence …

Extrinsic versus intrinsic uniformity correction for γ-cameras

R Bolstad, J Brown, V Grantham - Journal of nuclear medicine …, 2011 - Soc Nuclear Med
SPECT produces nuclear medicine images using a 3-dimensional diagnostic tool that
eliminates the superimposition of adjacent structures, thus providing improved disease …

Spatial resolution properties of FB and ML-EM reconstruction methods

DW Wilson, BMW Tsui - 1993 IEEE Conference Record Nuclear …, 1993 - ieeexplore.ieee.org
We investigated the spatial resolution and quantitative properties of SPECT images
reconstructed using filteredbackprojection (FB) and maximum likelihood-expectation …

Comparison of multi-ray and point-spread function based resolution recovery methods in pinhole SPECT reconstruction

A Sohlberg, H Watabe, T Zeniya… - Nuclear medicine …, 2006 - journals.lww.com
Methods Resolution recovery was incorporated into ordered subsets expectation
maximization reconstruction algorithm. The first of the correction methods used a simple but …

Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a …

T Yokei, H Shinohara, H Onishi - Annals of nuclear medicine, 2002 - Springer
Iterative reconstruction techniques such as an ordered subsets-expectation maximization
(OSEM) algorithm can easily incorporated various physical models of attenuation or scatter …

Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study

C Vanhove, A Andreyev, M Defrise, J Nuyts… - European journal of …, 2007 - Springer
Purpose Low sensitivity can become a major problem when very small pinholes are used in
SPECT imaging. Although a larger pinhole aperture will improve the sensitivity, this will be at …

automated quantitative analysis of planar scintigraphic resolution with the ACR SPECT phantom

FP DiFilippo - Medical Physics, 2018 - Wiley Online Library
Purpose Evaluating gamma camera image quality is a routine task required for annual
physics surveys and laboratory accreditation. A common method is visual assessment of a …

SPECT: Quality control procedures and artifact identification

BA Harkness, WL Rogers, NH Clinthorne… - Journal of Nuclear …, 1983 - Soc Nuclear Med
Commercially available single photon emission computed tomography (SPECT) cameras
require both new calibration and very careful routine quality control procedures. These …

[PDF][PDF] Quality assurance in PET: Evaluation of the clinical relevance of detector defects

R Buchert, KH Bohuslavizki, J Mester… - Journal of Nuclear …, 1999 - Soc Nuclear Med
Defective detector blocks in PET may cause serious image artifacts. Toestimatetheinfluenceofmalfunctioningdet…
image quality, a method is described for transferringthe actual detector defect onto …