Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function

KA Morton, DE Pisani, JH Whiting… - Journal of nuclear …, 1997 - Soc Nuclear Med
Glomerular filtration rate (GFR) is an important index of renal function. Twenty-four-hour
creatinine clearance overestimates GFR in patients with poor renal function. Inulin and …

Measurement of glomerular filtration rate using 99mTc-DTPA and the gamma camera: a comparison of methods

CD Russell, PG Bischoff, F Kontzen, KL Rowell… - European journal of …, 1985 - Springer
A variety of methods have been proposed to estimate the glomerular filtration rate (GFR)
from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare …

Comparison of four commercial Tc-99m (Sn) DTPA preparations used for the measurement of glomerular filtration rate: concise communication.

JE Carlsen, ML Møller, JO Lund… - Journal of Nuclear …, 1980 - europepmc.org
To find a commercially available DTPA preparation that could be used for the measurement
of glomerular filtration rate (GFR), the plasma clearances of four different Tc-99m (Sn) DTPA …

Technical aspects of a new technique for estimating glomerular filtration rate using technetium-99m-DTPA

KL Rowell, FN Kontzen, ME Stutzman… - Journal of nuclear …, 1986 - Soc Nuclear Med
Technetium-99m-DTPA has previously been proposed as an appropriate
radiopharmaceutical for the determination of glomerular filtration rate (GFR). Some 99mTc …

Determination of glomerular filtration rate with 99mTc-DTPA in clinical practice.

G Galli, V Rufini, G Meduri, R Piraccini… - Journal of Nuclear …, 1994 - europepmc.org
In order to assess the practical reliability of glomerular filtration rate (GFR) determination
with 99mTc-DTPA and plasma sampling, the authors compared the results obtained with …

Measurement of glomerular filtration rate using sup (99m) Tc-DTPA and the gamma camera: A comparison of methods

CD Russel, PG Bischoff, F Kontzen… - European Journal of …, 1985 - inis.iaea.org
[en] A variety of methods have been proposed to estimate the glomerular filtration rate (GFR)
from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. The compare …

A comparison between four simple methods for measuring glomerular filtration rate using technetium-99m DTPA

M Ginjaume, M Casey, F Barker… - Clinical nuclear …, 1986 - journals.lww.com
Numerous centers perform glomerular filtration rate (GFR) measurements on patients
undergoing renal imaging with Tc-99m DTPA. GFR measurement, however, does involve …

[PDF][PDF] Quality control of Tc-99m DTPA for measurement of glomerular filtration: concise communication

CD Russell, PG Bischoff, KL Rowell… - Journal of Nuclear …, 1983 - Soc Nuclear Med
When technetium-99m DTPA is used to measure glomerular filtration rate (GFR), the
accuracy dependson the supplierof the radiopharmaceutical. The error in GFR is due to …

[PDF][PDF] Comparison of methods for calculating glomerular filtration rate: technetium-99m-DTPA scintigraphic analysis, protein-free and whole-plasma clearance of …

JJ Goates, KA Morton, WW Whooten… - Journal of Nuclear …, 1990 - Soc Nuclear Med
Nuclear Medicine and Research Services, VA Medical Center, Salt Lake City, Utah;
Departments of Radiology and Pathology, University of Utah School ofMedicine, Salt Lake …

Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA: A comparison with simultaneous 125I …

K Rootwelt, D Falch, R Sjökvist - European Journal of Nuclear Medicine, 1980 - Springer
Abstract 99m Tc-DTPA was prepared from a kit produced by the Institute of Atomic Energy,
Oslo, Norway. Radiochemical purity as determined with gel chromatography ranged from …